XRES4 Neuro Claim Study
ClarityIQ is a novel X-ray imaging technology, that combines advanced real-time image noise reduction algorithms, with state-of-the-art hardware to reduce patient entrance dose significantly. This is realized by anatomy-specific optimization of the full acquisition chain (grid switch, beam filtering, pulse width, spot size, detector and image processing engine) for every clinical task individually. Furthermore, smaller focal spot sizes and shorter pulses are used, which are known to positively influence image quality . The final effect on the clinical image quality is investigated in this study.
The advent of interventional neuroradiology (INR) has changed the treatment of neurovascular
diseases by reducing the procedural invasiveness and the recovery time needed by patients,
thus improving clinical outcome. However, INR procedures often require many high-quality
digital substraction angiography (DSA) runs and long total fluoroscopy times, which can
result in patients being exposed to considerable radiation doses levels.
In order to introduce a dose reduction technology the most important aspect is to validate
the diagnostic image information. Philips has developed a real-time noise reduction
algorithm for DSA in neuroradiology that is capable to reduce the patient entrance dose by
75% without loss of image quality.
;
Allocation: Non-Randomized, Intervention Model: Crossover Assignment, Masking: Double Blind (Investigator, Outcomes Assessor), Primary Purpose: Diagnostic
Status | Clinical Trial | Phase | |
---|---|---|---|
Not yet recruiting |
NCT06235619 -
Arch Size Study for Anatomical Variations
|
||
Not yet recruiting |
NCT00905931 -
Lycopene Following Aneurysmal Subarachnoid Haemorrhage
|
Phase 2 | |
Completed |
NCT01178710 -
Effect of Simvastatin on Cardiac Function
|
N/A | |
Completed |
NCT00349908 -
A Feasibility Study of the Cordis Neurovascular Self Expanding Stent System in Intracranial Arteries
|
Phase 1 | |
Recruiting |
NCT03285100 -
The Effects of Discontinuation of Vitamin K Antagonists on the Rate of Elastin Degradation
|
N/A | |
Recruiting |
NCT06189950 -
Registration Trial of the Intracranial Visualized Stent for the Wide-necked Intracranial Aneurysms:REBRIDGE
|
N/A | |
Active, not recruiting |
NCT04592185 -
The Study of the Fenestrated Anaconda Device in the Treatment of Abdominal Aortic Aneurysms
|
||
Completed |
NCT01970605 -
Silver Graft All Comers Registry
|
||
Completed |
NCT00282893 -
Balloon Prophylaxis of Aneurysmal Vasospasm
|
Phase 2 | |
Active, not recruiting |
NCT00549380 -
Clinical Study of Aneurysm Exclusion
|
Phase 1 | |
Completed |
NCT04598802 -
COvera in BRAnch Registry
|
||
Completed |
NCT04246125 -
Patient Skin Dose in Interventional Radiology
|
||
Recruiting |
NCT05829746 -
PROSPECTIVE, MULTI-CENTER, OPEN-LABEL, SINGLE-ARM REGISTRATION TRIAL OF THE TUBRIDGE FOR THE TREATMENT OF WIDE-NECKED SMALL AND MEDIUM-SIZED INTRACRANIAL ANEURYSMS
|
N/A | |
Completed |
NCT03242343 -
VasQ External Support for Arteriovenous Fistula
|
N/A | |
Recruiting |
NCT02878967 -
Standardized Long Term Follow-up of Patients After Endovascular Embolization of a Brain Aneurysm
|
||
Active, not recruiting |
NCT02345005 -
Iliac Branch Excluder ReGistry (IceBERG)
|
||
Recruiting |
NCT02167997 -
EffectiveNess and SAfety of Small ANeurysm COiling Trial
|
N/A | |
Recruiting |
NCT00549016 -
Clinical Study of Aneurysm Exclusion
|
N/A | |
Completed |
NCT02848612 -
Evaluation of the Amiens University Hospital Neuroradiology Anticoagulation Protocol
|
||
Enrolling by invitation |
NCT04269447 -
Prospective Aortic Biobank of POP-STAR
|