Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT02264977
Other study ID # SSB 11-03
Secondary ID
Status Completed
Phase N/A
First received
Last updated
Start date April 2015
Est. completion date March 2022

Study information

Verified date August 2022
Source W.L.Gore & Associates
Contact n/a
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

The purpose of this study is to assess the early feasibility of the use of the GORE® TAG® Thoracic Branch Endoprosthesis to treat aneurysms involving the aortic arch


Description:

The GORE® TAG® Thoracic Endoprosthesis (TAG® Device) received premarket approval (PMA) for use in endovascular aneurysm repair of the descending thoracic aorta (DTA) on 23-Mar-2005 under P040043, and design changes that resulted in the conformable GORE® TAG® Thoracic Endoprosthesis (CTAG) received premarket approval for the treatment of aneurysms of the DTA on 23-Aug-2011 (P040043/S039). The TAG® Device and CTAG are intended to exclude an aneurysm from the blood circulation in patients diagnosed with DTA aneurysms. However, endovascular treatment options for patients with aortic arch aneurysms are limited as current stent graft technology would require coverage of aortic arch vessels. This prompted the creation of the GORE® TAG® Thoracic Branch Endoprosthesis (previously known as Branched TAG® Device), which was being evaluated under IDE G130120 for Zone 2 aneurysms when this clinical investigation was initiated to evaluate the GORE® TAG® Thoracic Branch Endoprosthesis for the treatment of Zone 0 and Zone 1 aneurysms of the aortic arch.


Recruitment information / eligibility

Status Completed
Enrollment 9
Est. completion date March 2022
Est. primary completion date July 2016
Accepts healthy volunteers No
Gender All
Age group 18 Years and older
Eligibility Inclusion Criteria: 1. Presence of aortic aneurysm involving the aortic arch deemed to warrant surgical repair which requires proximal graft placement in Zone 0 or Zone 1: 1. Fusiform (= 55 mm), or 2. Fusiform (>2 times native aortic diameter), or 3. Saccular (no diameter criteria) 2. Subject is considered a high risk candidate for conventional open surgical repair at the discretion of the Investigator 3. Age =18 years at time of informed consent signature 4. Subject is capable of complying with protocol requirements, including follow-up 5. Informed Consent Form (ICF) is signed by Subject or legal representative 6. Must have appropriate proximal aortic landing zone, defined as: 1. Must require placement of the proximal extent of the Aortic Component in Zone 0 or Zone 1 for exclusion of the lesion 2. Acceptable proximal landing zone outer curvature length for the required device 3. Landing zone inner diameters between 16-48 mm in Zone 1 Subjects and 24-48mm in Zone 0 Subjects 4. Landing zone, which must include either the brachiocephalic or left common carotid native ostium, cannot be aneurysmal, heavily calcified, or heavily thrombosed 7. Must have appropriate distal aortic landing zone, defined as: 1. Outer curvature length must be =2cm proximal to the celiac artery 2. Aortic inner diameters between 16-48 mm (diameter must be between 16-42mm if using distal TAG® Device extension) 3. Landing zone cannot be aneurysmal, heavily calcified, or heavily thrombosed 4. Landing zone in native aorta or previously implanted GORE® TAG® Device 8. Must have appropriate target branch vessel landing zone, defined as: 1. Length of =3 cm proximal to first major branch vessel if using Aortic Component with 8 mm portal diameter, or length of =2.5 cm proximal to first major branch vessel if using Aortic Component with 12 mm portal diameter (required for Zone 0 Subjects) 2. Target branch vessel inner diameters of 6-15 mm if using Aortic Component with 8mm portal diameter, or inner diameters of 11-18 mm if using Aortic Component with 12mm portal diameter (required for Zone 0 Subjects) 3. Target branch vessel landing zone must be in native aorta that cannot be aneurysmal, heavily calcified, or heavily thrombosed Exclusion Criteria: 1. Concomitant aneurysm/disease of the ascending aorta, or abdominal aorta requiring repair 2. Previous endovascular repair of the ascending aorta 3. Previous endovascular repair of the DTA with a non-Gore device 4. Surgery within 30 days of treatment 5. Infected aorta 6. Dissection of the aorta 7. Intramural hematoma of the aortic arch or DTA without aneurysm 8. Life expectancy <2 years 9. Myocardial infarction or stroke within 6 weeks prior to treatment 10. Patient has a systemic infection and may be at increased risk of endovascular graft infection 11. Pregnant female at time of informed consent signature 12. Degenerative connective tissue disease, e.g. Marfan's or Ehler-Danlos Syndrome 13. Participation in another drug or medical device study within one year of study enrollment 14. Known history of drug abuse within one year of treatment 15. Significant thrombus or atheroma in the aortic arch 16. Tortuous or stenotic iliac and/or femoral arteries preventing introducer sheath insertion and the inability to use a conduit for vascular access 17. Planned coverage of celiac artery 18. Patient has known sensitivities or allergies to the device materials 19. Patient has known hypersensitivity or contraindication to anticoagulants or contrast media, which is not amenable to pre-treatment 20. Previous instance of Heparin Induced Thrombocytopenia type 2 (HIT-2) or known hypersensitivity to heparin 21. Diameter taper outside of the device sizing range between proximal and distal landing zones of aorta and the inability to use additional devices of different diameters to compensate for the taper 22. Mycotic aneurysm 23. Persistent refractory shock (systolic blood pressure <90 mm Hg) 24. Patient has body habitus or other medical condition which prevents adequate visualization of the aorta

Study Design


Related Conditions & MeSH terms


Intervention

Device:
GORE® TAG® Thoracic Branch Endoprosthesis


Locations

Country Name City State
United States University of Michigan Ann Arbor Michigan
United States The Hitchcock Foundation (Dartmouth Hitchcock Medical Center) Lebanon New Hampshire
United States Hospital at University of Pennsylvania Philadelphia Pennsylvania
United States Univerisity of Pittsburgh Medical Center Pittsburgh Pennsylvania
United States Mayo Clinic Rochester Rochester Minnesota
United States Leland Stanford Junior University Stanford California

Sponsors (1)

Lead Sponsor Collaborator
W.L.Gore & Associates

Country where clinical trial is conducted

United States, 

Outcome

Type Measure Description Time frame Safety issue
Primary Number of Participants With Successful Study Device Access Access to the aneurysm and target landing zone location is obtained via conventional vascular access and endovascular techniques. During treatment procedure (day 0)
Primary Number of Participants With Successful Study Device Deployment Absence of deployment failure will be considered a successful deployment. Deployment failure will be considered the failure of any Branched TAG® Device component (Aortic Component, Aortic Extender, or SB Component) to be released from the delivery catheter resulting in a serious adverse event (SAE) due to mechanical failure or use error. During treatment procedure (day 0)
Primary Number of Participants With Primary Procedural Side Branch Patency The presence of forward flow through the implanted Side Branch Component into the target branch vessel. At conclusion of the treatment procedure (day 0)
Secondary Number of Participants With 1 Month Side Branch Primary Patency Assessed by an Independent Core Lab 1 Month
Secondary Number of Participants Without 1 Month Device Related Endoleaks Assessed by an Independent Core Lab Device-related endoleaks are defined as the presence of contrast within the aneurysm sac originating from the junction between any Branched TAG® Device component and the landing zone (Type IA or IB) or the junction between the Aortic Component and either the Side Branch Component or the Aortic Extender (Type III). 1 Month
See also
  Status Clinical Trial Phase
Completed NCT00606190 - Prospective Randomized Study of Brain Protection During Aortic Arch Replacement N/A