Clinical Trials Logo

Clinical Trial Summary

To analyze the effects of the use of Gastro-laryngeal Tube on intraoperative and postoperative hemodynamics, procedure comfort, and cardiologist and patient satisfactions during transesophageal echocardiography.


Clinical Trial Description

Transesophageal echocardiography (TEE) is an ultrasonic imaging method providing anatomic, functional and hemodynamic information by imaging the heart and thoracic vascular structures using a probe advanced through the esophagus toward the stomach. The probe, with an ultrasonic wave converter at the tip, is placed in the patient's esophagus and begins assessment at the closest location to the heart. This position allows detailed assessment of the heart. It is commonly used during heart surgery, while it is also used in outpatient practice during cardiology examinations for diagnostic purposes. Currently, TEE is performed with the outpatient admission concept in procedure rooms of the relevant departments as a semi-invasive procedure. TEE provides relatively higher quality and detailed assessments compared to transthoracic echocardiography (TTE). When images obtained with TEE are compared with TTE images, posterior structures like the interatrial septum, mitral valve, left atrium and pulmonary veins were reported to be assessed at superior levels. In addition to this advantage of TEE, the presence of the TEE probe in the oropharyngeal passage and need for deep sedation involve high complication risks. During sedation administration, the common use of the oropharyngeal passage by both cardiologist and anesthesiologist forms a risk in terms of airway management. Especially during deep sedation and analgesia, special equipment and manipulation may be required for the safety of airway management. In modern medical approaches, priority has begun to be given to procedure comfort, along with diagnosis and treatment of the patient. With this aim, endoscopic esophagus procedures are frequently performed under sedation. Sedation administration is not an innocent procedure, and management includes many difficulties. The incidence of complications related anesthesia and the procedure is variable, but hypoxia, unplanned endotracheal intubation secondary to desaturation or aspiration, accidental tracheal insertion of gastroscope, bronchospasm, laryngospasm and hemodynamic instability may be encountered. A review of the literature stated the hypoxia incidence related to sedation was 1.5-70%. The broad interval of incidence is stated to be linked to the use, or not, of airway protective approaches. The importance given to patient comfort and satisfaction and desire of endoscopist to perform procedures more reliably and with shared responsibility have opened the door to new research and innovations. This demand has motivated industry to develop new pharmaceutical agents and medical instruments. The gastro-laryngeal tube (GLT) is designed with the aim of ensuring the safety of airway management and optimum performance of endoscopy for esophageal procedures under deep sedation and is a new tool offered for use. GLT is a modification of a laryngeal tube allowing passage of the gastroscope or TEE probe, a suitable channel for manipulation and ensuring supraglottic airway control at the same time. There are two inflatable cuffs, one within the esophagus and the other in the hypopharynx. These cuffs ensure airway safety and stabilization of the gastro-laryngeal tube. The investigators hypothesized that GLT, allowing passage of the TEE probe and ensuring supraglottic airway control, would provide more advantages in terms of hemodynamic stabilization, complications related airway management, cardiologist and patient satisfactions when used in a clinical setting. To date, there has been no detailed prospective clinical study analyzing the performance of the GLT during TEE. The present study sought to address this gap by performing a prospective clinical study to analyze the performance of the GLT during TEE. Primary outcome measures were safety of airway management, and cardiologist and patient satisfactions. This study also recorded demographic characteristics, intraoperative and postoperative hemodynamics, level of hypoxemia, and duration of procedure as secondary outcome measures. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05272306
Study type Interventional
Source Bezmialem Vakif University
Contact
Status Completed
Phase N/A
Start date April 13, 2022
Completion date September 20, 2022

See also
  Status Clinical Trial Phase
Active, not recruiting NCT04279054 - Decreased Neuraxial Morphine After Cesarean Delivery Early Phase 1
Active, not recruiting NCT04580030 - Tricuapid Annular Plane Sistolic Excursion Before General Anesthesia Can Predict Hypotension After Induction
Completed NCT03640442 - Modified Ramped Position for Intubation of Obese Females. N/A
Recruiting NCT04099693 - A Prospective Randomized Study of General Anesthesia Versus Anesthetist Administered Sedation for ERCP
Terminated NCT02481999 - Pre- and Postoperative EEG-Monitoring for Children Aged From 0,5 to 8 Years
Completed NCT04235894 - An Observer Rating Scale of Facial Expression Can Predict Dreaming in Propofol Anesthesia
Recruiting NCT05525104 - The Effect of DSA on Recovery of Anaesthesia in Children (Het Effect Van DSA op Het Herstel na Anesthesie Bij Kinderen). N/A
Recruiting NCT05024084 - Desflurane and Sevoflurane Minimal Flow Anesthesia on Recovery and Anesthetic Depth Phase 4
Completed NCT04204785 - Noise in the OR at Induction: Patient and Anesthesiologists Perceptions N/A
Completed NCT03277872 - NoL, HR and MABP Responses to Tracheal Intubation Performed With MAC Blade Versus Glidescope N/A
Terminated NCT03940651 - Cardiac and Renal Biomarkers in Arthroplasty Surgery Phase 4
Terminated NCT02529696 - Measuring Sedation in the Intensive Care Unit Using Wireless Accelerometers
Completed NCT05346588 - THRIVE Feasibility Trial Phase 3
Terminated NCT03704285 - Development of pk/pd Model of Propofol in Patients With Severe Burns
Recruiting NCT05259787 - EP Intravenous Anesthesia in Hysteroscopy Phase 4
Completed NCT02894996 - Does the Response to a Mini-fluid Challenge of 3ml/kg in 2 Minutes Predict Fluid Responsiveness for Pediatric Patient? N/A
Completed NCT05386082 - Anesthesia Core Quality Metrics Consensus Delphi Study
Terminated NCT03567928 - Laryngeal Mask in Upper Gastrointestinal Procedures N/A
Recruiting NCT06074471 - Motor Sparing Supraclavicular Block N/A
Completed NCT04163848 - CARbon Impact of aNesthesic Gas