Clinical Trials Logo

Clinical Trial Summary

The proposed study is designed to further demonstrate the performance of the Nociception Level (NoL) Index - in surgical patient under general anesthesia, by evaluating its response to controlled changes in the levels of noxious stimuli/analgesia and to correlate early outcome predictors to the NoL values throughout the surgical procedure, thus provide the medical caregiver general recommendations on how to interpret the NoL Index in terms of magnitude and direction, and how to utilize it during the surgical procedure.


Clinical Trial Description

The proposed study is designed to further demonstrate the performance of the NoL Index in surgical patient under general anesthesia, by evaluating its response to controlled changes in the levels of noxious stimuli/analgesia mentioned characteristics and to correlate early outcome predictors to the NoL values throughout the surgical procedure, thus provide the medical caregiver general recommendations on how to interpret the NoL Index in terms of magnitude and direction, and how to utilize it during the surgical procedure. In this study the investigators plan to demonstrate that the NoL Index is a continuous index. It is anticipated that a higher level of nociception will correspond to a higher NoL index. On the other hand, it is anticipated that higher levels of analgesic agent for the same noxious stimulus will lead to a lower NoL index. This will be achieved by measuring the NoL response to various types of noxious stimuli, varying in their intensities, under different levels of analgesic agents. The noxious stimuli that will be used in this pivotal study are: 1. - Intubation 2. - Incision and/or trocar insertion 3. - Internal handling during the surgical procedure 4. - Extubation 5. - Other specific pain event related to the surgical procedure (e.g. bone related treatment in orthopedic, muscle tension or cut etc.). The study population includes subjects requiring a surgical procedure under general anesthesia. During the surgical procedure the subject is anesthetized (by various anesthetic agents) and paralyzed (by muscle relaxant agents). Thus, the response to noxious stimuli under those conditions will be related to the underlying physiological response. The participants will be monitored, as in a typical surgery and according to the local guidelines, by various types of monitoring devices, such as: vital signs, pulse oximeter, Bispectral Index (BIS), Electroencephalography (EEG) etc. Therefore, patients suffering from fluctuations in their vital signs and hemodynamic parameters during the surgical procedure, can be detected by the various monitors. However, assessment of the level of nociception is still complex, subjective and mainly depends on the physician's experience and knowledge. Development of a nociception monitor that may present an index to assess the level of nociception will allow the anesthesiologist better patient management during the surgical procedure. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT03466138
Study type Observational
Source Medasense Biometrics Ltd
Contact
Status Completed
Phase
Start date December 13, 2016
Completion date December 1, 2020

See also
  Status Clinical Trial Phase
Active, not recruiting NCT04580030 - Tricuapid Annular Plane Sistolic Excursion Before General Anesthesia Can Predict Hypotension After Induction
Active, not recruiting NCT04279054 - Decreased Neuraxial Morphine After Cesarean Delivery Early Phase 1
Completed NCT03640442 - Modified Ramped Position for Intubation of Obese Females. N/A
Recruiting NCT04099693 - A Prospective Randomized Study of General Anesthesia Versus Anesthetist Administered Sedation for ERCP
Terminated NCT02481999 - Pre- and Postoperative EEG-Monitoring for Children Aged From 0,5 to 8 Years
Completed NCT04235894 - An Observer Rating Scale of Facial Expression Can Predict Dreaming in Propofol Anesthesia
Recruiting NCT05525104 - The Effect of DSA on Recovery of Anaesthesia in Children (Het Effect Van DSA op Het Herstel na Anesthesie Bij Kinderen). N/A
Recruiting NCT05024084 - Desflurane and Sevoflurane Minimal Flow Anesthesia on Recovery and Anesthetic Depth Phase 4
Completed NCT04204785 - Noise in the OR at Induction: Patient and Anesthesiologists Perceptions N/A
Completed NCT03277872 - NoL, HR and MABP Responses to Tracheal Intubation Performed With MAC Blade Versus Glidescope N/A
Terminated NCT03940651 - Cardiac and Renal Biomarkers in Arthroplasty Surgery Phase 4
Terminated NCT02529696 - Measuring Sedation in the Intensive Care Unit Using Wireless Accelerometers
Completed NCT05346588 - THRIVE Feasibility Trial Phase 3
Terminated NCT03704285 - Development of pk/pd Model of Propofol in Patients With Severe Burns
Recruiting NCT05259787 - EP Intravenous Anesthesia in Hysteroscopy Phase 4
Completed NCT02894996 - Does the Response to a Mini-fluid Challenge of 3ml/kg in 2 Minutes Predict Fluid Responsiveness for Pediatric Patient? N/A
Completed NCT05386082 - Anesthesia Core Quality Metrics Consensus Delphi Study
Terminated NCT03567928 - Laryngeal Mask in Upper Gastrointestinal Procedures N/A
Recruiting NCT06074471 - Motor Sparing Supraclavicular Block N/A
Completed NCT04163848 - CARbon Impact of aNesthesic Gas