This study is being performed to determine the effectiveness of Fluid Intravenous Alert (FIVA) in monitoring intravenous fluid delivered to patients under anesthesia in a dimmed ambient light in the operating room.


Description:

Background and Rationale

The first intravenous (IV) system was developed by Dr. Thomas Latta in 1832 to treat Cholera patients. Following its introduction, the IV delivery system has been widely adopted as a means of fluid resuscitation, rehydration and administration of blood products, medications and vasopressors. Today, it is a standard practice to place an IV catheter in all patients requiring an operation in the hospital setting. Intravenous fluid is administered through the IV tubing into the vein and carries the drugs that are needed for induction and maintenance of anesthesia. This IV fluid comes in several varieties which contain different amount of electrolytes, glucose, acidity or starch and is stored in a variety of volumes in sterile bags (most commonly 500 ml and 1000 ml). Once connected to the IV catheter through the IV tubing, the fluid bag is hung on the IV pole above the patient and flow into the patient by gravity.

In the nursing wards, IV fluids are routinely administered via infusion pumps, which can deliver fluid at specified rates and volumes and would sound alarms when the selected volumes of fluid have been completed. While this is an effective means of administering IV fluid, it is a time-consuming process to set up the IV fluid pump and program the infusion volume and rate. Perioperative fluid administration is a rapidly changing process and most anesthesiologists would prefer more control over the rate than pre-programed pumps. In the operating room environment, the rate and manner of drug and fluid administration are highly variable. Therefore, almost all IV fluid administered systems are gravity-fed.

In busy operating rooms, anesthesiologists carefully observe the progress of surgery and the anesthetic state of patients through different monitors. Intravenous fluid bags often run empty unnoticed because the IV fluid bags are hung above the eye level of the anesthesiologist. Even a vigilant anesthesiologist may not be able to promptly detect dry the IV fluid bag. In a previous observational study, the incidence of undetected dry IV bags has been shown to be 29.6%. However, the length of time before an empty bag is noticed is unknown. According to a recent survey about the working conditions in the operating room, including 471 surgeons and 405 nurses, most of the reported intra-operative hazards were due to insufficient illumination of the operating room especially during dangerous situations, such as unexpected bleeding. In the presence of dimmed ambient light in the operating room, e.g. during endoscopic surgeries, it is probably more difficult to visually monitor the flow of IV fluid with higher incidence of undetected dry IV bags. Several potential clinical adverse events can occur if the dry IV bag is not detected promptly. Firstly, if the gravity-fed IV fluid is being used as a carrier to administer drugs, such as anesthetics for total intravenous anesthesia (TIVA), or the infusion of vasopressors, awareness under anesthesia or unstable hemodynamics may occur. Secondly, during fluid or volume resuscitation, the IV fluid delivery system is frequently pressurized in order to deliver fluid as quickly as possible to the unstable patient. The pressurized IV fluid bag can force the air present in the IV fluid bag into the IV tubing when the fluid runs out. This can potentially cause air embolism. Finally, undetected dry IV bags can disrupt fluid flow through the catheter into the patient, allowing blood to pool around the catheter. If a clot is formed, it will occlude the line and prevent any further fluid flow. This may necessitate recannulation of the anesthetized patient during surgery which may be technically challenging.

The FIVA™ (EngenuityMED, Halifax, Canada) is a small, handheld, battery operated, device class I medical device in Canada. It is designed to alarm and alert the physician to change the IV bag when the fluid level in the chamber of the IV set is low. It also functions to stop the fluid flow through the gravity-fed tubing system when the alarm is triggered, preventing air from entering the IV tubing.

We hypothesize that the FIVA would decrease the incidence of unnoticed dry IV bags during surgery, particularly when the operating room lights are dimmed and would therefore decrease the risks associated with undetected dry IV bags.


Recruitment information / eligibility

Status Completed
Enrollment 90
Est. completion date December 2017
Est. primary completion date December 2017
Accepts healthy volunteers No
Gender All
Age group N/A and older
Eligibility Inclusion Criteria:

- Attending anesthesiologists scheduled for elective surgical procedures at the Queen Elizabeth II Health Sciences Centre (QEII).

Exclusion Criteria:

- Attending anesthesiologists scheduled for elective surgical procedures at the QEII with cases where lights to not dimmed.

Study Design


Related Conditions & MeSH terms


Intervention

Device:
Fluid Intravenous Alert (FIVA) 'on'
Fluid Intravenous Alert (FIVA) 'on' - The FIVA™ (EngenuityMED, Halifax, Canada) is a small, handheld, battery operated, device class I medical device in Canada (Figure 1). It is designed to alarm and alert the physician to change the IV bag when the fluid level in the chamber of the IV set is low. It also functions to stop the fluid flow through the gravity-fed tubing system when the alarm is triggered, preventing air from entering the IV tubing. We hypothesize that the FIVA would decrease the incidence of unnoticed dry IV bags during surgery, particularly when the operating room lights are dimmed and would therefore decrease the risks associated with undetected dry IV bags.
Fluid Intravenous Alert (FIVA) 'off'
The FIVA will be turned off. - The FIVA™ (EngenuityMED, Halifax, Canada) is a small, handheld, battery operated, device class I medical device in Canada. It is designed to alarm and alert the physician to change the IV bag when the fluid level in the chamber of the IV set is low. It also functions to stop the fluid flow through the gravity-fed tubing system when the alarm is triggered, preventing air from entering the IV tubing. We hypothesize that the FIVA would decrease the incidence of unnoticed dry IV bags during surgery, particularly when the operating room lights are dimmed and would therefore decrease the risks associated with undetected dry IV bags.

Locations

Country Name City State
n/a

Sponsors (1)

Lead Sponsor Collaborator
Nova Scotia Health Authority

References & Publications (6)

Hung OR, Comeau. L. Incidence of intra-operative cessation of intravenous (iv) fluid administration. Can J Anesth 1998;45:A5.

Janakan G, Ellis H. Dr Thomas Aitchison Latta (c1796-1833): pioneer of intravenous fluid replacement in the treatment of cholera. J Med Biogr. 2013 May;21(2):70-4. doi: 10.1258/jmb.2012.012004. — View Citation

Matern U, Koneczny S. Safety, hazards and ergonomics in the operating room. Surg Endosc. 2007 Nov;21(11):1965-9. Epub 2007 May 5. — View Citation

Mendenhall ML, Spain DA. Venous air embolism and pressure infusion devices. J Trauma. 2007 Jul;63(1):246. — View Citation

Mirski MA, Lele AV, Fitzsimmons L, Toung TJ. Diagnosis and treatment of vascular air embolism. Anesthesiology. 2007 Jan;106(1):164-77. Review. — View Citation

Pant D, Narani KK, Sood J. Significant air embolism: A possibility even with collapsible intravenous fluid containers when used with rapid infuser system. Indian J Anaesth. 2010 Jan;54(1):49-51. doi: 10.4103/0019-5049.60498. — View Citation

Outcome

Type Measure Description Time frame Safety issue
Primary Incidence of undetected dry IV bags For the duration of the surgery
Secondary Type of surgical procedure Questionnaire Baseline
Secondary Duration of surgical procedure Questionnaire Baseline
Secondary Presence of air in the IV Questionnaire For the duration of surgery
Secondary Number of false alarms triggered by the FIVA device during the procedure For the duration of surgery
Secondary VAS assessment of ease of use of the FIVA For the duration of surgery
Secondary Loudness of audial alarm of the FIVA Questionnaire For the duration of surgery
Secondary Ease of use of the FIVA Questionnaire For the duration of surgery
See also
  Status Clinical Trial Phase
Active, not recruiting NCT04279054 - Decreased Neuraxial Morphine After Cesarean Delivery Early Phase 1
Active, not recruiting NCT04580030 - Tricuapid Annular Plane Sistolic Excursion Before General Anesthesia Can Predict Hypotension After Induction
Completed NCT03640442 - Modified Ramped Position for Intubation of Obese Females. N/A
Recruiting NCT04099693 - A Prospective Randomized Study of General Anesthesia Versus Anesthetist Administered Sedation for ERCP
Terminated NCT02481999 - Pre- and Postoperative EEG-Monitoring for Children Aged From 0,5 to 8 Years
Completed NCT04235894 - An Observer Rating Scale of Facial Expression Can Predict Dreaming in Propofol Anesthesia
Recruiting NCT05525104 - The Effect of DSA on Recovery of Anaesthesia in Children (Het Effect Van DSA op Het Herstel na Anesthesie Bij Kinderen). N/A
Recruiting NCT05024084 - Desflurane and Sevoflurane Minimal Flow Anesthesia on Recovery and Anesthetic Depth Phase 4
Completed NCT04204785 - Noise in the OR at Induction: Patient and Anesthesiologists Perceptions N/A
Completed NCT03277872 - NoL, HR and MABP Responses to Tracheal Intubation Performed With MAC Blade Versus Glidescope N/A
Terminated NCT03940651 - Cardiac and Renal Biomarkers in Arthroplasty Surgery Phase 4
Terminated NCT02529696 - Measuring Sedation in the Intensive Care Unit Using Wireless Accelerometers
Completed NCT05346588 - THRIVE Feasibility Trial Phase 3
Terminated NCT03704285 - Development of pk/pd Model of Propofol in Patients With Severe Burns
Recruiting NCT05259787 - EP Intravenous Anesthesia in Hysteroscopy Phase 4
Completed NCT02894996 - Does the Response to a Mini-fluid Challenge of 3ml/kg in 2 Minutes Predict Fluid Responsiveness for Pediatric Patient? N/A
Completed NCT05386082 - Anesthesia Core Quality Metrics Consensus Delphi Study
Terminated NCT03567928 - Laryngeal Mask in Upper Gastrointestinal Procedures N/A
Recruiting NCT06074471 - Motor Sparing Supraclavicular Block N/A
Completed NCT04163848 - CARbon Impact of aNesthesic Gas