Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT02439606
Other study ID # E-14-1074
Secondary ID
Status Completed
Phase N/A
First received April 1, 2015
Last updated May 6, 2015
Start date May 2014
Est. completion date December 2014

Study information

Verified date May 2015
Source King Saud University
Contact n/a
Is FDA regulated No
Health authority Saudi Arabia: Ministry for Higher Education
Study type Interventional

Clinical Trial Summary

This prospective randomized trial evaluated Parker Flex-It stylet as an alternative to manufacturer, s GlideRite® Rigid Stylet to aid intubation with the GlideScope in patients undergoing elective non-cardiac surgery that required general anesthesia with orotracheal intubation.


Description:

The GlideScope® Ranger (GVL; Verathon Medical Inc., Bothell, WA, USA) is a novel portable, reusable video laryngoscope that has provided superior laryngeal visualization to facilitate tracheal intubation especially in the management of difficult airways; it provides indirect visualization of the glottis with a pronounced angle of 60° in the blade. It has separate monitor connected to the handle via a cable. The tip of the blade is equipped with high-resolution digital video camera, an LED light and an antifogging system.

Unlike the Macintosh laryngoscope, an indirect laryngoscope such as the GlideScope device provides a view of the glottis without the need to align the oral pharyngeal and laryngeal axes facilitating an excellent glottic visualization. However, insertion and advancement of the endotracheal tube (ETT) may be more difficult to pass through the vocal cords than direct laryngoscopy, and trauma is possible.

The GlideScope have shown to function better when used in conjunction with use of a stylet to guide insertion of endotracheal tube. The GlideRite Rigid Stylet (GRS) is a reusable rigid steel stylet, specifically designed by the manufacturer to resemble the distal part of the GVL blade for clear view of the airway, enabling quick intubation , its curvature approaches 90° with a radius of curvature of approximately 6 cm.

Various investigators have recommended different curvatures of the ETT/stylet to optimally direct it into the trachea, including matching the blade's 60° angle, configuring the ETT with a 90° bend, or using a J-shaped ETT. Other potential strategies may include the use of a flexible stylet that allows active modification of the tip of the tracheal tube during use.

The Parker Flex-It Directional Stylet (FIS, Parker Medical, Highlands Ranch, CO) is a 2-piece plastic stylet, can be used for oral intubation, and allows continuous adjustment of the tube curvature during an intubation to enable the tube to follow the curvature of the airway. We hypothesized that the use of Parker Flex-It stylet to guide ETT might offer some benefit over the GRS.

Therefore, the purpose of this study was to determine the optimal stylet-tracheal tube strategy for use with the GlideScope® laryngoscope. We compared efficacy of the two intubating aids including GlideRite® Rigid Stylet versus Parker Flex-It stylet for orotracheal intubation in terms of the total intubation time (primary outcome), ease of intubation, the number of intubation attempts , the number of optimization man oeuvres and possible trauma (secondary outcomes) when used by experienced GlideScope operators.


Recruitment information / eligibility

Status Completed
Enrollment 60
Est. completion date December 2014
Est. primary completion date December 2014
Accepts healthy volunteers Accepts Healthy Volunteers
Gender Both
Age group 18 Years to 50 Years
Eligibility Inclusion Criteria:

- ASA physical status I&II,

- body mass index (BMI) < 35

- elective non-cardiac surgery

- general anaesthesia with orotracheal intubation

Exclusion Criteria:

- Anticipated difficult airway,

- need for rapid sequence induction,

- ASA physical status III-V,

- increase risk of gastric aspiration such as gastro- oesophageal reflux,

- pregnancy,

- patients who had no teeth, loose teeth or oral trauma, known pathology or previous surgery to the mouth, pharynx, larynx or cervical spine and any reason why the GlideScope is not, or could not be used.

Study Design

Allocation: Randomized, Endpoint Classification: Efficacy Study, Intervention Model: Parallel Assignment, Masking: Single Blind (Outcomes Assessor), Primary Purpose: Supportive Care


Related Conditions & MeSH terms


Intervention

Device:
Glide Rite Rigid Stylet group
Intubation with the GlideScope® video-laryngoscope and styletted the tracheal tube using manufacturer's GlideRite Rigid Stylet (GRS) (GVL - ST1; Verathon Medical Inc., Bothell, WA, USA). Time till successful intubation of the patient is calculated.
Parker Flex-It directional stylet group
Intubated with the GlideScope® video-laryngoscope and styletted the tracheal tube using Parker-Flex-It directional Stylet (Parker Medical, Colorado, USA) (Flexi-Stylet). Time till successful intubation of the patient is calculated.

Locations

Country Name City State
n/a

Sponsors (1)

Lead Sponsor Collaborator
King Saud University

Outcome

Type Measure Description Time frame Safety issue
Primary total intubation time the time from insertion of the blade of the GlideScope into the oral airway to the appearance of end-tidal carbon dioxide (ETCO2) curve of at least 30 mmHg on the anesthesia monitor after insertion of the tracheal tube. measured during intubation ( up to 120 seconds) No
Secondary number of intubation attempts before successful intubation 5minutes No
See also
  Status Clinical Trial Phase
Active, not recruiting NCT04279054 - Decreased Neuraxial Morphine After Cesarean Delivery Early Phase 1
Active, not recruiting NCT04580030 - Tricuapid Annular Plane Sistolic Excursion Before General Anesthesia Can Predict Hypotension After Induction
Completed NCT03640442 - Modified Ramped Position for Intubation of Obese Females. N/A
Recruiting NCT04099693 - A Prospective Randomized Study of General Anesthesia Versus Anesthetist Administered Sedation for ERCP
Terminated NCT02481999 - Pre- and Postoperative EEG-Monitoring for Children Aged From 0,5 to 8 Years
Completed NCT04235894 - An Observer Rating Scale of Facial Expression Can Predict Dreaming in Propofol Anesthesia
Recruiting NCT05525104 - The Effect of DSA on Recovery of Anaesthesia in Children (Het Effect Van DSA op Het Herstel na Anesthesie Bij Kinderen). N/A
Recruiting NCT05024084 - Desflurane and Sevoflurane Minimal Flow Anesthesia on Recovery and Anesthetic Depth Phase 4
Completed NCT04204785 - Noise in the OR at Induction: Patient and Anesthesiologists Perceptions N/A
Completed NCT03277872 - NoL, HR and MABP Responses to Tracheal Intubation Performed With MAC Blade Versus Glidescope N/A
Terminated NCT03940651 - Cardiac and Renal Biomarkers in Arthroplasty Surgery Phase 4
Terminated NCT02529696 - Measuring Sedation in the Intensive Care Unit Using Wireless Accelerometers
Completed NCT05346588 - THRIVE Feasibility Trial Phase 3
Terminated NCT03704285 - Development of pk/pd Model of Propofol in Patients With Severe Burns
Recruiting NCT05259787 - EP Intravenous Anesthesia in Hysteroscopy Phase 4
Completed NCT02894996 - Does the Response to a Mini-fluid Challenge of 3ml/kg in 2 Minutes Predict Fluid Responsiveness for Pediatric Patient? N/A
Completed NCT05386082 - Anesthesia Core Quality Metrics Consensus Delphi Study
Terminated NCT03567928 - Laryngeal Mask in Upper Gastrointestinal Procedures N/A
Recruiting NCT06074471 - Motor Sparing Supraclavicular Block N/A
Completed NCT04163848 - CARbon Impact of aNesthesic Gas