Clinical Trials Logo

Clinical Trial Summary

Background - The purpose of the present study is to evaluate the success and pharyngeal trauma when 3 or 6 cm height of pillow is used for the ProSealTM laryngeal mask airway insertion

Methods

- This prospective randomized, controlled study included 80 adult patients . In the 3 cm (n=40) or 6 cm group (n=40), the PLMA was inserted while the head is placed on the 3 cm or 6 cm height of pillow. The success rate at first and second attempt, insertion time, blood staining on cuff, sore throat and hoarseness were assessed.


Clinical Trial Description

Background: The "sniffing position" (i.e., the neck flexed and head extended by means of a pillow) eases tracheal intubation because the three axes, namely, the axis of the mouth, the pharyngeal axis and the laryngeal axis, are put in almost a straight line. The benefit of the sniffing position that align three axis could possibly be applicable when the ProSeal LMA is inserted. For the endotracheal intubation, it has been recommended to elevate the patient's head 8 to 10 cm with pads under the occiput (shoulder remaining on the table) and extend the head at the atlanto-occipital joint to align the oral, pharyngeal, and laryngeal axes such that the passage and line of vision from the lips to the glottic opening are most nearly a straight line.

There have been several clinical studies about the effect of head and neck position including neutral, flexion or extension on the ease of LMA insertion.

However, it has not been much recommended or investigated about the influence of head elevation on the insertion success of PLMA until now. The purpose of the present study is to evaluate the success and pharyngeal trauma when 3 or 6 cm height of pillow is used for the ProSeal laryngeal mask airway insertion in adult patients. ;


Study Design

Allocation: Randomized, Intervention Model: Parallel Assignment, Masking: Single Blind (Subject)


Related Conditions & MeSH terms


NCT number NCT02058030
Study type Interventional
Source National Medical Center, Seoul
Contact
Status Completed
Phase N/A
Start date November 2013
Completion date December 2014

See also
  Status Clinical Trial Phase
Active, not recruiting NCT04580030 - Tricuapid Annular Plane Sistolic Excursion Before General Anesthesia Can Predict Hypotension After Induction
Active, not recruiting NCT04279054 - Decreased Neuraxial Morphine After Cesarean Delivery Early Phase 1
Completed NCT03640442 - Modified Ramped Position for Intubation of Obese Females. N/A
Recruiting NCT04099693 - A Prospective Randomized Study of General Anesthesia Versus Anesthetist Administered Sedation for ERCP
Terminated NCT02481999 - Pre- and Postoperative EEG-Monitoring for Children Aged From 0,5 to 8 Years
Completed NCT04235894 - An Observer Rating Scale of Facial Expression Can Predict Dreaming in Propofol Anesthesia
Recruiting NCT05525104 - The Effect of DSA on Recovery of Anaesthesia in Children (Het Effect Van DSA op Het Herstel na Anesthesie Bij Kinderen). N/A
Recruiting NCT05024084 - Desflurane and Sevoflurane Minimal Flow Anesthesia on Recovery and Anesthetic Depth Phase 4
Completed NCT04204785 - Noise in the OR at Induction: Patient and Anesthesiologists Perceptions N/A
Completed NCT03277872 - NoL, HR and MABP Responses to Tracheal Intubation Performed With MAC Blade Versus Glidescope N/A
Terminated NCT03940651 - Cardiac and Renal Biomarkers in Arthroplasty Surgery Phase 4
Terminated NCT02529696 - Measuring Sedation in the Intensive Care Unit Using Wireless Accelerometers
Completed NCT05346588 - THRIVE Feasibility Trial Phase 3
Terminated NCT03704285 - Development of pk/pd Model of Propofol in Patients With Severe Burns
Recruiting NCT05259787 - EP Intravenous Anesthesia in Hysteroscopy Phase 4
Completed NCT02894996 - Does the Response to a Mini-fluid Challenge of 3ml/kg in 2 Minutes Predict Fluid Responsiveness for Pediatric Patient? N/A
Completed NCT05386082 - Anesthesia Core Quality Metrics Consensus Delphi Study
Terminated NCT03567928 - Laryngeal Mask in Upper Gastrointestinal Procedures N/A
Recruiting NCT06074471 - Motor Sparing Supraclavicular Block N/A
Completed NCT04163848 - CARbon Impact of aNesthesic Gas