Clinical Trial Summary

Primary Objective: Conduct a prospective, observational pilot study that assesses the frequency and severity of anesthesia charting fidelity weaknesses in three separate clinical environments (Cardiac surgical operating room, cardiac surgical intensive care unit, and electrophysiology laboratory) as assessed by a customized error scoring system that focuses on the magnitude of errors among multiple continuous, categorical and dichotomous variables. The errors are being assessed in order to identify the most common charting inaccuracies so that target areas appropriate for testing of improvement strategies may be isolated.


Clinical Trial Description

1. Primary Objective: Conduct a prospective, observational pilot study that assesses the frequency and severity of anesthesia charting fidelity weaknesses in three separate clinical environments (Cardiac surgical operating room, cardiac surgical intensive care unit, and electrophysiology laboratory) as assessed by a customized error scoring system that focuses on the magnitude of errors among multiple continuous, categorical and dichotomous variables. The errors are being assessed in order to identify the most common charting inaccuracies so that target areas appropriate for testing of improvement strategies may be isolated. 1. Cardiac surgical operating room: Any cardiac surgical procedure that involves the use of cardiopulmonary bypass and planned postoperative intensive care unit admission in an electronic supplemented anesthesia charting environment 2. Cardiac surgical intensive care unit: The cardiac surgical intensive care unit environment during the first 2-3 hours following procedures referenced in section I,A,1 3. Electrophysiology laboratory: select electrophysiology laboratory based procedures that employ a paper anesthesia chart 2. Secondary and Exploratory Objectives: 1. Identify environmental variables that contribute significantly to medical record errors. 2. Identify clinical role of individual responsible for charting 3. Investigate time of day/patterns that charting errors occur 4. Relationship of clinical acuity and event occurrences 5. Role of equipment malfunction and event frequency 6. Role of social distracters and event frequency 7. Role of monitor infidelity and event frequency 8. Role of delayed charting of event and frequency of errors 9. Identify/quantify the awareness of clinicians to their execution of medical record errors through use of simple, multiple choice 4 question survey that clinicians will be asked to fill out following a case study 10. Examine the relationship between the assessed environments and the frequency of medical charting errors 11. Identify the areas of anesthesia charting most in need of improvement in order to address designing ways to potentially improve these weaknesses. Error scoring system: 1. The degree of charting fidelity error in this study will be converted via a classification system to make data analysis more efficient. All types of errors that involve continuous variables will be assessed with mean, median and standard deviation as well as range. Numerical data points related to time will be classified into four separate categories. 1. Class It: temporally accurate data will less than 2 minutes or 3.3% deviation from actual time of event/observation. 2. Class IIt: temporally inaccurate data with between 2-3 minutes or 3.3-5% deviation from actual time of event/observation. 3. Class IIIt: temporally inaccurate data with between 3-6 minutes or 5-10% deviation from actual time of event/observation. 4. Class IVt: temporally inaccurate data with greater than 10% deviation (6 min) from actual time of event/observation. 2. The degree of charting fidelity error observed with respect to hemodynamic parameters will be classified as follows: 1. Class Ih: accurate hemodynamic data with less than 3% deviation from the representative value recorded by the scribe. 2. Class IIh: inaccurate hemodynamic data with between 3-5% deviation from the representative value recorded by the scribe. 3. Class IIIh: inaccurate hemodynamic data with between 5-10% deviation from the representative value recorded by the scribe. 4. Class IVh: inaccurate hemodynamic data with greater than 10% deviation from the representative value recorded by the scribe. 3. The degree of charting fidelity error observed with respect to whether a procedure which was performed by anesthesia provider was charted will be assessed as a dichotomous variable, Yes or No. 4. The degree of charting fidelity error observed with respect to whether a significant intraoperative event, or intra-procedural event for the electrophysiology laboratory, was charted will be assessed as a dichotomous variable, Yes or No. 5. The degree of charting fidelity error observed with respect to drug dosing will be assessed as a dichotomous variable, Yes or No. 6. The degree of charting fidelity error as related to procedural details will be assessed as a dichotomous variable, Yes or No. 7. Full statistical analysis making all possible comparisons of collected data will be performed with the assistance of a trained statistician. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT01179932
Study type Observational
Source University Hospitals Cleveland Medical Center
Contact
Status Withdrawn
Phase
Start date August 2010
Completion date August 2011

See also
  Status Clinical Trial Phase
Active, not recruiting NCT04580030 - Tricuapid Annular Plane Sistolic Excursion Before General Anesthesia Can Predict Hypotension After Induction
Active, not recruiting NCT04279054 - Decreased Neuraxial Morphine After Cesarean Delivery Early Phase 1
Completed NCT03640442 - Modified Ramped Position for Intubation of Obese Females. N/A
Recruiting NCT04099693 - A Prospective Randomized Study of General Anesthesia Versus Anesthetist Administered Sedation for ERCP
Terminated NCT02481999 - Pre- and Postoperative EEG-Monitoring for Children Aged From 0,5 to 8 Years
Completed NCT04235894 - An Observer Rating Scale of Facial Expression Can Predict Dreaming in Propofol Anesthesia
Recruiting NCT05525104 - The Effect of DSA on Recovery of Anaesthesia in Children (Het Effect Van DSA op Het Herstel na Anesthesie Bij Kinderen). N/A
Recruiting NCT05024084 - Desflurane and Sevoflurane Minimal Flow Anesthesia on Recovery and Anesthetic Depth Phase 4
Completed NCT04204785 - Noise in the OR at Induction: Patient and Anesthesiologists Perceptions N/A
Completed NCT03277872 - NoL, HR and MABP Responses to Tracheal Intubation Performed With MAC Blade Versus Glidescope N/A
Terminated NCT03940651 - Cardiac and Renal Biomarkers in Arthroplasty Surgery Phase 4
Terminated NCT02529696 - Measuring Sedation in the Intensive Care Unit Using Wireless Accelerometers
Completed NCT05346588 - THRIVE Feasibility Trial Phase 3
Terminated NCT03704285 - Development of pk/pd Model of Propofol in Patients With Severe Burns
Recruiting NCT05259787 - EP Intravenous Anesthesia in Hysteroscopy Phase 4
Completed NCT02894996 - Does the Response to a Mini-fluid Challenge of 3ml/kg in 2 Minutes Predict Fluid Responsiveness for Pediatric Patient? N/A
Completed NCT05386082 - Anesthesia Core Quality Metrics Consensus Delphi Study
Terminated NCT03567928 - Laryngeal Mask in Upper Gastrointestinal Procedures N/A
Recruiting NCT06074471 - Motor Sparing Supraclavicular Block N/A
Completed NCT04163848 - CARbon Impact of aNesthesic Gas