Anesthesia Clinical Trial
Official title:
The Influence of Two Different CO2 Absorbers on Sevoflurane Consumption During Anaesthesia
Traditional sodalime CO2 absorbers are known to not only react with CO2 but also with sevoflurane. Therewith, a potentially harmful compound (compound A) is formed that can be nephrotoxic. In the United States, the sevoflurane manufacturer therefore recommends keeping the FGF (FGF) at >2.0 L min-1 if a sodalime CO2 absorbent is used. Amsorb Plus® (Datex-Ohmeda Inc., Madison, WI, USA), is a novel type of CO2 absorbent that does not react with sevoflurane. This allows the FGF to be reduced to 0.5 L min-1. This has two important advantages: (i) less fresh sevoflurane is added to the circle system, and (ii) the sevoflurane that is in the system does not react with the CO2 absorber. Sevoflurane is a potent greenhouse gas with a 100 year CO2-equivalents of 120. Measures that can reduce the consumption of volatile anaesthetics could make a significant contribution to reducing the carbon footprint of the operative process. Additionally, Amsorb Plus® canisters seem to have a longer life span than sodalime canisters and do not need to be disposed of via toxic waste stream, but via domestic waste. In this study, we were interested if (i) the use of Amsorb Plus leads to a reduction in sevoflurane usage and therefore contribute to a reduction in the CO2 footprint of general anaesthesia with sevoflurane, (ii) Does the use of Amsorb Plus® lead to a reduction in the amount of (toxic) waste produced by operating theatres? Comparator: a traditional sodalime CO2 absorber (Medisorbâ„¢ Multi-Absorber Original, CareFusion, Helsinki, Finland).
n/a
Status | Clinical Trial | Phase | |
---|---|---|---|
Active, not recruiting |
NCT04279054 -
Decreased Neuraxial Morphine After Cesarean Delivery
|
Early Phase 1 | |
Active, not recruiting |
NCT04580030 -
Tricuapid Annular Plane Sistolic Excursion Before General Anesthesia Can Predict Hypotension After Induction
|
||
Completed |
NCT03640442 -
Modified Ramped Position for Intubation of Obese Females.
|
N/A | |
Recruiting |
NCT04099693 -
A Prospective Randomized Study of General Anesthesia Versus Anesthetist Administered Sedation for ERCP
|
||
Terminated |
NCT02481999 -
Pre- and Postoperative EEG-Monitoring for Children Aged From 0,5 to 8 Years
|
||
Completed |
NCT04235894 -
An Observer Rating Scale of Facial Expression Can Predict Dreaming in Propofol Anesthesia
|
||
Recruiting |
NCT05525104 -
The Effect of DSA on Recovery of Anaesthesia in Children (Het Effect Van DSA op Het Herstel na Anesthesie Bij Kinderen).
|
N/A | |
Recruiting |
NCT05024084 -
Desflurane and Sevoflurane Minimal Flow Anesthesia on Recovery and Anesthetic Depth
|
Phase 4 | |
Completed |
NCT04204785 -
Noise in the OR at Induction: Patient and Anesthesiologists Perceptions
|
N/A | |
Completed |
NCT03277872 -
NoL, HR and MABP Responses to Tracheal Intubation Performed With MAC Blade Versus Glidescope
|
N/A | |
Terminated |
NCT03940651 -
Cardiac and Renal Biomarkers in Arthroplasty Surgery
|
Phase 4 | |
Terminated |
NCT02529696 -
Measuring Sedation in the Intensive Care Unit Using Wireless Accelerometers
|
||
Completed |
NCT05346588 -
THRIVE Feasibility Trial
|
Phase 3 | |
Terminated |
NCT03704285 -
Development of pk/pd Model of Propofol in Patients With Severe Burns
|
||
Recruiting |
NCT05259787 -
EP Intravenous Anesthesia in Hysteroscopy
|
Phase 4 | |
Completed |
NCT02894996 -
Does the Response to a Mini-fluid Challenge of 3ml/kg in 2 Minutes Predict Fluid Responsiveness for Pediatric Patient?
|
N/A | |
Completed |
NCT05386082 -
Anesthesia Core Quality Metrics Consensus Delphi Study
|
||
Terminated |
NCT03567928 -
Laryngeal Mask in Upper Gastrointestinal Procedures
|
N/A | |
Recruiting |
NCT06074471 -
Motor Sparing Supraclavicular Block
|
N/A | |
Completed |
NCT04163848 -
CARbon Impact of aNesthesic Gas
|