Clinical Trials Logo

Clinical Trial Summary

The comfort and fit of the residual limb within a prosthetic socket are of primary concern for many amputees. The residual limb is typically covered by non-breathable and non- thermally conductive materials that can create a warm and ultimately moist environment. The investigators have developed a silicone liner approach to remove sweat from the skin and out of the socket and to passively conduct heat from the skin using thermally conductive elastomers. This liner has been developed to work alongside a thermo-electric cooling (TEC)-based module called the Intrasocket Cooling Element (ICE) developed in a parallel project by Vivonics, Inc. and Liberating Technologies, Inc. The ICE device can be embedded into the prosthesis in order to cool the residual limb. A technology that can provide thermal control while retaining adequate suspension, weight, and other prosthetic characteristics would benefit many prosthesis wearers.


Clinical Trial Description

The comfort and fit of the residual limb within a prosthetic socket are of primary concern for many amputees. The residual limb is typically covered by non-breathable and non- thermally conductive materials that can create a warm and ultimately moist environment. These layers consist of a prosthetic liner that rolls onto the limb and traps heat and occasional extra prosthetic socks. Studies found increases in socket temperature after the prosthesis was donned. Temperatures were found to remain elevated long after activity cessation and even a rest period of double the duration of the preceding activity period is insufficient to return the limb to its initial temperature. A small amount of activity can cause the socket temperature to elevate and remain at an uncomfortable level for an extended period of time, which can lead to decreased wear times. In summary, an uncomfortable socket/residual limb interface decreases prosthesis use among amputees who want to remain active in their lives. To address this, the investigators have developed a silicone liner approach to remove sweat from the skin and out of the socket and to passively conduct heat from the skin using thermally conductive elastomers. This liner has been developed to work alongside a thermo-electric cooling (TEC)-based module called the Intrasocket Cooling Element (ICE) developed in a parallel project by Vivonics, Inc. and Liberating Technologies, Inc. The ICE device can be embedded into the prosthesis in order to cool the residual limb. A technology that can provide thermal control while retaining adequate suspension, weight, and other prosthetic characteristics would benefit many prosthesis wearers. This study will focus on investigating the efficacy of this novel moisture and thermal management (experimental) liner. The rationale for this study is to determine how well the new technology can regulate the residual limb temperature, reduce the moisture generation, and remove excess moisture in a controlled laboratory environment. The primary objective of this study is to measure the effects experimental techniques of moisture and thermal management has on moisture and temperature in the socket. Moisture and thermal management of the residual limb inside the prosthetic socket could result in greater comfort while wearing the prosthesis, and ultimately could result in greater function and better quality of life (QoL). A repeated measures study will be conducted to analyze the temperature and moisture generation of the residual limb with and without the experimental liner and active cooling system within a standard prosthetic socket. Both able-bodied research subjects, and lower limb amputee research subjects who use transfemoral or transtibial prostheses will be recruited for testing. Liners for able-bodies subjects will have the distal end removed to allow for donning. All subjects will visit Liberating Technologies, Inc. to be consented and to complete study testing. A maximum of 10 able-bodied and 20 lower-limb amputee subjects will be recruited for this study. This is increased from a target 12 subjects to account for any drop-outs, etc. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04427007
Study type Interventional
Source Liberating Technologies, Inc.
Contact
Status Completed
Phase N/A
Start date July 1, 2020
Completion date January 16, 2022

See also
  Status Clinical Trial Phase
Recruiting NCT03947450 - Autologous Volar Fibroblast Injection Into the Stump Site of Amputees Phase 2
Completed NCT04924036 - Qbrexza Cloths for Hyperhidrosis of Amputation Sites Phase 2
Recruiting NCT04839497 - Multicenter Trial Evaluating the Safety and Efficacy of Autologous Volar Fibroblast Injection Into the Terminal Limb of Amputees. Phase 2
Recruiting NCT04212299 - Transfemoral Socket Design and Muscle Function N/A
Completed NCT03733054 - Understanding Prosthetic Needs and Outcomes in Women Veterans With Amputation
Completed NCT03651830 - A Test-Drive Strategy for the Prescription of Prosthetic Feet for People With Leg Amputations N/A
Recruiting NCT04725006 - Sensory Responses to Dorsal Root Stimulation N/A
Not yet recruiting NCT06007885 - Examining Capacity Building of Youth With Physical Disabilities to Pursue Participation Following the PREP Intervention. N/A
Not yet recruiting NCT04936789 - Clinical Feasibility of the IMES Transradial Prosthesis N/A
Completed NCT01155024 - Clinical Evaluation of Direct Manufactured Prosthetic Sockets Phase 2
Completed NCT00663663 - Telephone Intervention for Pain Study (TIPS) N/A
Terminated NCT00778856 - Hand Transplantation for the Reconstruction of Below the Elbow Amputations N/A
Recruiting NCT00388752 - Acupuncture for the Treatment of Phantom Limb and Residual Limb Pain After Amputation Phase 1
Active, not recruiting NCT03374319 - Somatotopic Configuration of Distal Residual Limb Tissues in Lower Extremity Amputations N/A
Completed NCT05542901 - Comparison of Joint Position Sense in Diabetic and Traumatic Transtibial Amputees N/A
Completed NCT05161364 - Kinetic Analysis Due to Foot Dysfunction
Recruiting NCT06194838 - Clinical Outcomes With Non-Powered vs. Powered Prosthetic Knees by K2-level Amputees N/A
Completed NCT03570788 - HRQoL Among Patients Amputated Due to Peripheral Arterial Disease
Completed NCT05778799 - Physical Activity and Sports for People With Special Needs
Recruiting NCT04804150 - Daily Socket Comfort in Transtibial Amputee With an Active Vacuum Suspension System N/A