Clinical Trials Logo

Clinical Trial Summary

Immediate implant placement has proven to be a successful treatment procedure that is preferred by patients because of being less traumatic, more time-efficient. Nowadays, the main goal of a successful immediate implant treatment has ceased to be gaining stability and osseointegration, but achieving long-term dimensional stability has become the optimal challenge. Various soft tissue and hard tissue augmentation techniques have been investigated in order to maintain the ridge dimensions following extraction and immediate implant placement.


Clinical Trial Description

It has been noted that the different augmentation procedures aid in decreasing the dimensional changes occurring after immediate implant placement in the esthetic zone. Even though immediate implant placement is a predictable procedure, however, labial bone resorption following tooth extraction is inevitable. The available surgical techniques present do not entirely prevent dimensional variations of the peri-implant hard and soft tissues over time. Furthermore, substantial evidence showed that immediate implant placement failed to halt the resorption of the thin buccal bony plate with subsequent gingival recession, particularly in patients with thin gingival phenotype ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05381467
Study type Interventional
Source Cairo University
Contact
Status Completed
Phase N/A
Start date March 1, 2022
Completion date December 15, 2022

See also
  Status Clinical Trial Phase
Not yet recruiting NCT05470673 - Autogenous Demineralized Dentin Graft Combined With Injectable PRF + Metronidazole Versus Autogenous Demineralized Dentin Graft Alone for Alveolar Ridge Preservation N/A
Recruiting NCT02580721 - The Influence of Mucosal Tissue Thickness on Soft and Hard Tissue Changes Around Implants N/A
Completed NCT02515058 - Ridge Preservation Following Tooth Extraction Using Two Mineralized Cancellous Bone Allografts N/A
Enrolling by invitation NCT02209311 - Effectiveness and Safety of Method of Maxilla Alveolar Process Reconstruction Using Synthetic Tricalcium Phosphate and Autologous MMSCs Phase 1/Phase 2
Completed NCT02602223 - Comparison of Amnion Chorion Membrane vs. Dense Polytetrafluoroethylene Membrane in Ridge Preservation Procedures Phase 2
Completed NCT02255149 - A Feasibility Study for Growth Bone Vertically With Titanium Mesh and Allograft in Lower Posterior Jaw N/A
Recruiting NCT05674331 - Clinical, Radiographical, Histological Evaluation and Blood Flow Analysis of Alveolar Ridge Preservation N/A
Recruiting NCT06081296 - Dimensional Changes in Alveolar Ridge Preservation N/A
Completed NCT03944811 - Bone Height Gain Following Transcrestal Sinus Floor Elevation Using Piezoelectric Surgery Versus The Conventional Osteotome Technique N/A
Completed NCT03045458 - Associations of Alveolar Bone Loss and Interleukin-1β Levels in One and Two Stage Surgical Procedures N/A
Completed NCT05595746 - Radiological Bone Loss on Different Levels of Dental Implants N/A
Completed NCT03357705 - Effectiveness in Limiting the Need to Elevate the Maxillary Sinus N/A
Recruiting NCT05311735 - Mineralized and Partial Demineralized Dentin Graft Compared to FDBA N/A
Completed NCT05494476 - Stability of the Marginal Bone Around Subcrestal Implants N/A
Not yet recruiting NCT05536479 - Evaluation of Autogenous Stored Versus Autogenous Fresh Mineralized Dentin Graft for Alveolar Ridge Preservation N/A
Active, not recruiting NCT02275767 - Histological Evaluation of Healing Following Ridge Preservation Using a Combined Cortical/Cancellous Mineralized Freeze-Dried Bone Allograft N/A
Active, not recruiting NCT02120053 - Interest of Bone Substitute Material in Immediate Complete Denture Phase 2/Phase 3
Completed NCT01728844 - GUIDOR® Growth Factor Enhanced Bone Graft Substitute for the Treatment of Periodontal Defects 6-months Post-Surgery N/A
Terminated NCT00991965 - Localized Alveolar Ridge Augmentation With Dental Implant N/A
Terminated NCT00991432 - Localized Alveolar Ridge Augmentation With Space Maintenance Devices N/A