Optimization the cuff pressure of the laryngeal tube (LT) in relation of the mechanical ventilation, and the reduction of potential leakage mucosal trauma. Comparison of the tightness of LT between the filling volume specified by the manufacturer (connectors are color coded syringe and blocker), 60cmH₂O, 50cmH₂O, 40cmH₂Ound 30cmH₂O. The measurement of the leakage occurs in ml / kg body weight.


Clinical Trial Description

The ventilation of both cuffs of the laryngeal tube by using the color coding of syringe and connector is a simple, fast and easy way to stabilize the tube and secure seal against the surrounding tissue.

The user of this method has only knowledge of the volume (ml), with which the cuff is vented, but not over the cuff pressure (cmH₂O) itself.

Permanently high pressures can cause to a lesions to necrosis in the adjacent tissue, on the other hand, the material of the bulging cuff fits less well the anatomy of the patient, leading to leaks in the breathing circuit.

Studies of pediatric anesthesia show that on 40cmH₂O reduces the volume of the leak in the laryngeal mask airway by reducing the cuff pressure and the ventilation is improved in sequence.

In the proposed study, the volume of leakage at the fill volume specified by the manufacturer (color coding), 60cmH₂O, 50cmH₂O, 40cmH₂O and 30cmH₂O to be captured. ;


Study Design

Endpoint Classification: Safety/Efficacy Study, Intervention Model: Single Group Assignment, Masking: Open Label, Primary Purpose: Treatment


Related Conditions & MeSH terms


NCT number NCT02300337
Study type Interventional
Source Johannes Gutenberg University Mainz
Contact
Status Completed
Phase N/A
Start date November 2014
Completion date January 2015

See also
  Status Clinical Trial Phase
Completed NCT04109898 - Comparison of Ease of I-gel Insertion With Two Different Techniques in Adults N/A
Recruiting NCT05030337 - Optimising Ventilation in Preterms With Closed-loop Oxygen Control N/A
Completed NCT02820792 - Non-Crossover Study of the LMA Protector Versus Ambu AuraGain N/A
Not yet recruiting NCT02458794 - Crossover Study of the LMA SupremeTM vs Ambu-Aura GainTM N/A
Completed NCT02572232 - Supraglottic Airway Devices in Pediatric Difficult Airway Situations N/A
Completed NCT04158323 - What is the Gold Standard of Airway Management in the Anticipated Difficult Airway
Completed NCT04158271 - Evaluation of Techniques for Tracheal Tube Exchange in Standard and Critical Care Patients N/A
Active, not recruiting NCT02627755 - GlideScope® vs GlideScope® + aScope® for Managing Difficult Airways. N/A
Completed NCT02923427 - I-gel vs LMA Supreme in Laparoscopic Gynecological Surgery N/A
Completed NCT01749033 - A New Insertion Technique for Laryngeal Mask Airway N/A
Completed NCT02611986 - Evaluation of Video Laryngoscopy (Video Macintosh-blade) and Direct Laryngoscopy (EMMA-Study) N/A
Enrolling by invitation NCT03760692 - I-gel vs Ambu AuraGain in Laparoscopic Gynecological Surgery N/A
Completed NCT01367678 - Mucosal Pressure of the Laryngeal Mask Airway Supreme Versus the i-Gel in Paralyzed Anesthetized Female Patients N/A
Recruiting NCT03251053 - Adverse Airway Effects From Tobacco and E-Cigarettes N/A
Recruiting NCT02777840 - High Flow Oxygen With THRIVE Gives Better Oxygenation in Rapid Sequence Induction Patients N/A
Completed NCT02048657 - The Effectiveness of Foley Airway Stylet Tool on Proseal LMA Insertion N/A
Completed NCT01371773 - Repositioning Method for Left-sided Double Lumen Tubes N/A
Terminated NCT02495259 - Comparison of Double Lumen Tube Placement Techniques N/A
Recruiting NCT02104453 - Comparative Evaluation of Three Airway Maneuvers in the Unconscious Apneic Person N/A
Completed NCT02943980 - Influenced the Type of Laryngoscopy the Intraoperative Nerve Monitoring During Thyroid Surgery N/A