Adverse Anesthesia Outcome Clinical Trial
Official title:
Laryngeal Mask Airway Supreme Versus Laryngeal Tube in Non-paralysed, Anesthetized Children. A Randomized, Crossover Study Assessing Oropharyngeal Leak Pressure and Fiberoptic Position Using the Size 2
The investigators test the hypothesis that oropharyngeal leak pressure and fiberoptic position differ between the size 2 LMA SupremeTM and the Laryngeal Tube LTS IITM in non-paralyzed anaesthetized pediatric patients
The Laryngeal Tube LTS IITM (VBM-Medizintechnik GmbH, Sulz a.N, Germany) is a well established reusable latex free, extraglottic airway device. A proximal (pharyngeal) and a distal (esophageal) cuff are inflated with a single cuff pilot line. In between lies the ventilation orifice. The LMA SupremeTM (Teleflex San Diego, CA, USA) is a single use well studied laryngeal mask airway. Both devices have a drain tube to allow access to the gastrointestinal tract. Actually there are no studies comparing Laryngeal Tube LTS IITM and LMA SupremeTM use in small children. Therefore the aim of this study was to evaluate the clinical performance of the Laryngeal Tube LTS IITM compared to the LMA SupremeTM. The investigators hypothesized that design differences should lead to differences in efficacy of seal and anatomic position. In this randomized, crossover study, the investigators test the hypothesis that in non-paralyzed pediatric patients the oropharyngeal leak pressure and fiberoptic position differs between the size 2 Laryngeal Tube LTS IITM and the LMA SupremeTM. ;
Allocation: Randomized, Endpoint Classification: Efficacy Study, Intervention Model: Parallel Assignment, Masking: Single Blind (Investigator), Primary Purpose: Treatment
Status | Clinical Trial | Phase | |
---|---|---|---|
Not yet recruiting |
NCT01350076 -
Liberal Versus Goal-directed Intraoperative Fluid Therapy in Pediatric Patients
|
Phase 2 | |
Withdrawn |
NCT02121951 -
Quadratus Lumborum Block for Percutaneous Nephrostomy
|
Phase 4 | |
Not yet recruiting |
NCT02977559 -
A Study Between the Laryngeal Tube Suction-Disposable and the Ambu AuraGain in Pediatric Patients
|
N/A | |
Completed |
NCT01575236 -
A Randomized Non Crossover Study of the GuardianTM Versus SupremeTM Laryngeal Mask Airway
|
Phase 3 | |
Recruiting |
NCT01898897 -
Influence of Anesthesia Technique on Postoperative Evolution After Urogenital Surgical Interventions
|
N/A | |
Completed |
NCT03015857 -
Phenylephrine and Noradrenaline for Post Spinal Anesthesia Hypotension
|
Phase 2 | |
Completed |
NCT02884986 -
Analgesia in Inguinal Hernia Repair Using a Cyclooxygenase-2-specific Inhibitor
|
N/A | |
Completed |
NCT02856672 -
Trial Comparing the Laryngeal Tube Suction Disposable and the Supreme Laryngeal Mask Airway
|
N/A | |
Completed |
NCT02859922 -
Comparison Between the Supreme Laryngeal Mask Airway and the Laryngeal Tube Suction During Spontaneous Ventilation
|
N/A | |
Completed |
NCT00468598 -
The Prognostic Value of Troponin T for Long-term Outcome After Cardiac Surgery
|
N/A | |
Recruiting |
NCT02883192 -
The Effect of Preventive Use of Ondansetron in the Cesarean Section Under Spinal Anesthesia
|
N/A | |
Not yet recruiting |
NCT02866890 -
The New Laryngeal Tube Suction-Disposable for Childrens
|
N/A | |
Completed |
NCT02570269 -
Prospective Comparison of Oral Intubation Via - Ambu® Aura Gain™ vs Slotted Guedel Tubus
|
N/A | |
Not yet recruiting |
NCT02884869 -
Comparison of Direct Laryngoscopy With Blind Intubation Via Intubating Laryngeal Mask Airway
|
N/A | |
Not yet recruiting |
NCT02884843 -
The New Intubating Laryngeal Tube Suction-Disposable
|
N/A | |
Not yet recruiting |
NCT02884895 -
A Comparison of Direct Laryngoscopy With Blind Intubation Via Intubating Laryngeal Tube Suction Disposable
|
N/A | |
Completed |
NCT02884921 -
Preemptive Analgesia Using Intravenous Paracetamol
|
N/A |