Clinical Trial Summary

High values of cardiac troponin (Ct) in acute heart failure (ADHF) identify patients (pts) at higher risk and worsened prognosis. A Ct increase during therapy indicates the need for more appropriate intervention, aimed at compensating cardiac disease and effectively minimizing myocardial wall stress and subsequent cytolysis. This study evaluated the effects of an intravenous high-dose of furosemide with or without small-volume hypertonic saline solution (HSS)on myocardial cytolysis in ADHF pts.


Description:

After randomization, all patients included in the study underwent a complete physical examination, including a careful check of HF signs and symptoms, including BW measurement (in the morning before breakfast), supine and standing blood pressure (BP [the mean of 3 measurements]), and heart rate (HR). Fasting blood samples were drawn to determine the serum levels of Na, K, Cl, bicarbonate, albumin, uric acid, creatinine, urea, and glycemia on a daily basis during hospitalization, and this was continued until a clinically compensated state was obtained. The total daily output of urine was collected for measuring levels of creatinine clearance, urinary Na and K. A chest radiograph, electrocardiogram, and echocardiogram (prior to commencing therapy and again when discharged. In addition, BNP and TNI plasma levels will be evaluated for all patients on entry and at discharge. Each patient provided written informed consent prior to participating in the study.

In order to determine GFR, the MDRD formula (Modification of Diet in Renal Disease), involving 4 parameters, was deployed. It provides an estimate of GFR comparable or superior to other formulae, with the advantage of not requiring any anthropometric measurements. According to the MDRD, GFR can be estimated using the following formula: GFR (ml/min/1.73m2) = 175 x {[serum creatinine (mg / dL or μmol/L/88.4)] -1.154 x {age (years) }-0.203 x 0.742 if female and 1.21 if Afro-American. The estimating of GFR by means of the MDRD formula is a useful and valid tool with which to obtain an index of kidney function.

The echocardiography M / B mode color Doppler will be performed with a Vivid 7 echocardiograph, with patients in a supine position and slightly left lateral decubitus. The mitral flow and the time taken for the wave to return to baseline (DTE) were evaluated from the apical 4 room positions, placing the sample volume of pulsed Doppler at the peak of the valve leaflets during the opening. Subsequently, the speed of early diastolic movement (Ea) of mitral annulus, obtained from the 4 room projection placing the sample volume of pulsed tissue Doppler onto lateral corner of the annulus, was assessed as an index of left ventricular relaxation. By measuring the Ea wave and the E / Ea ratio, the PCWP was evaluated in a quantitative way according to the following formulae:

PCWP = 1.24 E / Ea + 1.91 for those in sinus rhythm PCWP = 0.821 E / Ea + 6.489 for those in atrial fibrillation. Calculating dp/dt. The calculating of dp/dt was performed by a spectral analysis of mitral regurgitation at CW Doppler. Two points were chosen on the mitral regurgitation curve for the correct calculation of echocardiographic dp / dt: A: speed 1 m / sec = 4 mm Hg; and B: speed 3 m / sec = 36 mm Hg. The pressure gradient between these two point was reported to be 32 mmHg (A - B = 36 - 4 = 32). dP/dT was calculated by dividing the pressure gradient between the two points for the temporal distance between them: dP / dT = 32mmHg / T msec.

Bioelectrical impedance variables will be detected with an impedance plethysmograph using a previously-described methodology (18). This emitted an alternating sinusoidal electric current of 800 mA and an operating single frequency of 50 kHz; it which was calibrated each morning using a standard resistor supplied by the manufacturer. BIA is a method for detecting whole-body fluid overload and pulmonary congestion, based on the theory that the accumulation of whole-body or intrathoracic fluid will conduct an electrical current passing across the body or trunk more easily, leading to a decrease in whole-body or pulmonary bioimpedance. Bioimpedance is a combination of resistance (Rz) (ie, the opposition of an alternating current flowing through intra- and extra-cellular ionic solutions) and reactance (Xc) (ie, the capacitative component of tissue interfaces, cell membranes, and organelles). As previous described, in standard whole-body tetrapolar BIA, sensing electrodes were placed on: the dorsum of the wrist, a line between the radial and ulnar styloid processes, the dorsum of the ipsilateral foot, and on a line between the medial and lateral malleoli. Source electrodes were placed to overlie the head of the third metacarpal on the dorsum of the hand and the third metatarsal on the dorsum of the foot, on the same side as the sensing electrodes. The measurements will be performed on the right side of the body with the patients in a semi-orthopneic or supine position. According to the RzXc graph method of the BIA vector, the impedance measurement will be standardized according to the height (H) of the subject, expressing both Rz/H and Xc/H in ohm/meters, to establish the hydration state. Bioelectrical impedance measurements will be assessed twice by the same experienced operator and paired measurements for each patient were used in the analysis.


Recruitment information / eligibility

Status Completed
Enrollment 60
Est. completion date September 2011
Est. primary completion date September 2011
Accepts healthy volunteers No
Gender Both
Age group 18 Years to 95 Years
Eligibility Inclusion Criteria:

- signs/symptoms of heart failure;

- New York Heart Association (NYHA) functional Class III or IV on admission due to an exacerbation of symptoms with at least 1 class deterioration;

- evidence of systolic dysfunction on echocardiographic examination on admission (EF<45%);

- BNP levels on admission > 100pg/mL

Exclusion Criteria:

- NYHA class < III on admission or without a NYHA class improvement on discharge;

- acute coronary syndrome,

- pulmonary thromboembolism,

- cardiac tamponade,

- pericarditis,

- renal insufficiency (serum creatinine <2,5 mg/dL, BUN <60 mg/dL) or those on dialysis;

- chronic liver disease,

- pleuro-pneumonia,

- blood and autoimmune diseases,

- concomitant other important co-morbidity,

- cerebral vascular disease,

- dementia,

- cancer,

- uncompensated diabetes,

- took non-steroid anti-inflammatory drugs (NSAID)

- declining to provide informed consent,

- patients requiring pacemaker implantation and those with issues of excessive alcohol consumption

Study Design

Allocation: Randomized, Endpoint Classification: Efficacy Study, Intervention Model: Parallel Assignment, Masking: Double Blind (Subject, Investigator), Primary Purpose: Treatment


Related Conditions & MeSH terms


Intervention

Drug:
Furosemide
125-250 mg furosemide bid
Furosemide
125-250 mf furosemide bid

Locations

Country Name City State
Italy Department of Internal and Specialty Medicine Palermo
Italy Gaspare PArrinello Palermo
Italy GF Ingrasasia Hospital Palermo

Sponsors (1)

Lead Sponsor Collaborator
University of Palermo

Country where clinical trial is conducted

Italy, 

References & Publications (2)

Kociol RD, Pang PS, Gheorghiade M, Fonarow GC, O'Connor CM, Felker GM. Troponin elevation in heart failure prevalence, mechanisms, and clinical implications. J Am Coll Cardiol. 2010 Sep 28;56(14):1071-8. doi: 10.1016/j.jacc.2010.06.016. Review. — View Citation

Parrinello G, Paterna S, Di Pasquale P, Torres D, Mezzero M, Cardillo M, Fasullo S, La Rocca G, Licata G. Changes in estimating echocardiography pulmonary capillary wedge pressure after hypersaline plus furosemide versus furosemide alone in decompensated — View Citation

Outcome

Type Measure Description Time frame Safety issue
Primary troponin I plasma levels (pg/ml) troponin I will be evaluated at entry and at dicharge participants will be followed for the duration of hospital stay, an expected average of 1 weeks No
See also
  Status Clinical Trial Phase
Enrolling by invitation NCT02003040 - Role of the Mespere Venus 1000 in Predicting Heart Failure Hospital Readmissions N/A
Unknown status NCT01700023 - 3-dimensional Sensor Technology to Quantify Leg-edema N/A
Terminated NCT03998410 - Evaluation of the Diagnostic Value of the TPD System in Determining ADHF Causing Acute Dyspnea N/A
Completed NCT01316432 - PK/PD Study of Subcutaneous Cenderitide Infusion in CHF Patients Phase 1
Recruiting NCT04905160 - Care Coordination to Assess Improvement in Outcomes in Hospital Readmissions N/A
Recruiting NCT05677100 - Diuretics Alone vs. Aortix Endovascular Device for Acute Heart Failure N/A
Recruiting NCT06169540 - Salivary Extracellular Vesicle Associated lncRNAs in Heart Failure (SEAL-HF)