Clinical Trials Logo

Clinical Trial Summary

The aim of this Pilot Study is to demonstrate the safety and efficacy of the use of Tetranite Implant Stabilization Material (TN-ISM) in delivering enhanced stability to immediately restored dental implants inserted into fresh extraction sockets, with both clinical and patient-related successful outcomes.


Clinical Trial Description

The purpose of the present study is to evaluate the safety and efficacy of a single stage approach using Tetranite Implant Stabilization Material (TN-ISM). The purpose of the efficacy component of this study is a composite comprising: (1) First - To demonstrate and evaluate the ability of TN-ISM to achieve immediate implant stabilization in sites otherwise unable to provide primary stability without requiring the delay in treatment imposed by the current multi-staged standard-of-care method; (2) Second - To demonstrate and evaluate the ability of TN-ISM to achieve increasing short-term stabilization of implants as the device undergoes initial resorption and replacement with new bone; (3) Third - To demonstrate the ability of TN-ISM to aid in the maintenance of alveolar ridge contours without buccal plate collapse and loss of crestal bone height; and Fourth (4) - To demonstrate and evaluate the ability of a TN-ISM stabilized implant to achieve implant success (after criteria of Buser, et. al 1) after 12 months in situ while the device undergoes significant resorption, facilitates osteoconduction, and replacement with new bone. In addition to the Primary Endpoints of establishing the Safety and Efficacy of Implant Stabilization and Implant Success throughout the initial 12 months of post-implant and device placement, the study also assesses several secondary endpoints over the course of the study and one-year follow-up, as outlined in the sections below. These include assessment of incidence, duration, and severity of adverse effects and events; assessment of increasing implant stiffness; assessment of bone levels, bone volumetric changes; patient satisfaction surveys, and assessment of periodontal and peri-implant health integral to implant success. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05535426
Study type Interventional
Source RevBio
Contact Michael R Norton
Phone 020 7486 9229
Email drnorton@nortonimplants.com
Status Recruiting
Phase N/A
Start date September 22, 2022
Completion date March 1, 2024

See also
  Status Clinical Trial Phase
Completed NCT04121364 - Immediate Placement and Stabilization of Dental Implants With Tetranite Stabilization Material in Mandibular and Maxillary Tooth Extraction Sites That Fail to Provide Adequate Primary Stability