Clinical Trial Summary

This cross-over study will compare the asynchrony index between standard manual ventilator settings, optimized manual ventilator settings, and automated ventilator setting in intensive care patients ventilated in non-invasive ventilation with a high asynchrony index. The hypothesis is that both manual optimized ventilator settings and automated ventilator settings are associated with a lower patient-ventilator asynchrony index as compared to manual standard ventilator settings. A randomized cross-over design method will be used. Patient requiring NIV with an asynchrony index over 35% will be included. An esophageal catheter with a balloon will be inserted to monitor esophageal pressure. Patients will be ventilated during 3 periods of 30 min, with 10 minutes of washout in between. Recordings of airway pressure, airway flow, and esophageal pressure will be analyzed by two investigators blinded of the trigger settings. The primary outcome will be the asynchrony index. The secondary outcome will be the ineffective inspiratory effort index, autotrigering index, double triggering index, inspiratory trigger delay, cycling delay, total time spent in asynchrony, patient comfort, and blood gas results.


Clinical Trial Description

Non-invasive ventilation (NIV) is used in 35% of patient admitted in intensive care unit (ICU) with a failure rate of 10 to 70% depending on the indication and clinician experience. Patient-ventilator asynchrony is a frequent cause of NIV failure. Therefore, optimizing patient-ventilator synchronization is important for its comfort, tolerance, and efficacy. An optimal patient-ventilation is achieved when the mechanical breath provided by the ventilator match the patient inspiratory effort. The ratio between the number of asynchronies divided by the number of patient inspiratory effort define the asynchrony index (AI). AI over 10% is considered as severe and occurs in 30 to 43% of patients ventilated in NIV. Patient ventilator asynchronies occurs because ventilator settings of inspiratory and expiratory triggers remain constant in patient with variable respiratory drive, and unintentionnals leaks that are difficult to control in NIV. Thus using an automatic adjustment of inspiratory and expiratory triggers setting according to patient effort and unintentional leaks may decrease the number of patient-ventilator asynchronies. This cross-over study will compare the asynchrony index between standard manual ventilator settings, optimized manual ventilator settings, and automated ventilator setting in intensive care patients ventilated in non-invasive ventilation with a high asynchrony index. The hypothesis is that both manual optimized ventilator settings and automated ventilator settings are associated with a lower patient-ventilator asynchrony index as compared to manual standard ventilator settings. A randomized cross-over design method will be used. Patient requiring NIV with an asynchrony index over 30% will be included. An esophageal catheter with a balloon will be inserted to monitor esophageal pressure. Patients will be ventilated during 3 periods of 30 min, with 10 minutes of washout in between. Recordings of airway pressure, airway flow, and esophageal pressure will be analyzed by two investigators blinded of the trigger settings. The primary outcome will be the asynchrony index. The secondary outcome will be the ineffective inspiratory effort index, autotrigering index, double triggering index, inspiratory trigger delay, cycling delay, total time spent in asynchrony, patient comfort, and blood gas results. The sample size was calculated from the total asynchrony index (primary outcome). Patients with an asynchrony index over 30% in using manual standard ventilator settings will be included. Considering an asynchrony index of 30 ± 15 % in manual standard ventilator settings with a clinically significant objective to reduce the asynchrony index to 15% in manual optimized ventilator settings and automated ventilator settings, a sample size of 30 patients is required with a risk at 0.05 and a power at 80%. Therefore, 35 patients are planned. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT03787173
Study type Interventional
Source Centre Hospitalier Intercommunal de Toulon La Seyne sur Mer
Contact
Status Completed
Phase N/A
Start date April 17, 2019
Completion date April 16, 2024

See also
  Status Clinical Trial Phase
Recruiting NCT05144633 - Blue Protocol and Eko Artificial Intelligence Are Best (BEA-BEST)
Completed NCT04534569 - Expert Panel Statement for the Respiratory Management of COVID-19 Related Acute Respiratory Failure (C-ARF)
Recruiting NCT03021902 - Nutrition and Exercise in Critical Illness Phase 2
Completed NCT02902146 - Bougie Use in Emergency Airway Management N/A
Completed NCT02901158 - Esophageal Manometry in Mechanically Ventilated Patients
Completed NCT02236559 - High Flow Therapy for the Treatment of Respiratory Failure in the ED N/A
Recruiting NCT02056093 - Comparison of Proportional Assist Ventilation And Neurally Adjusted Ventilator Assist N/A
Not yet recruiting NCT01668368 - Goal Directed Mechanical Ventilation Aimed at Optimal Lung Compliance N/A
Terminated NCT01083277 - Variable Ventilation During Acute Respiratory Failure N/A
Completed NCT01462279 - Effect of Thiamine on Oxygen Utilization (VO2) in Critical Illness N/A
Completed NCT01114022 - Prevention Inhalation of Bacterial by Using Endotracheal Tube Balloon Polyvinyl Chloride or Polyurethane N/A
Active, not recruiting NCT01058421 - Treatment of Critical Illness Polyneuromyopathy Phase 2
Completed NCT00252616 - Timing of Target Enteral Feeding in the Mechanically Ventilated Patient Phase 2/Phase 3
Recruiting NCT04098094 - Outcomes of RV Dysfunction in Acute Exacerbation of Chronic Respiratory Diseases
Recruiting NCT06051292 - Decremental Esophageal Catheter Filling Volume Titration For Transpulmonary Pressure Measurement N/A
Completed NCT04601090 - Survival Rates and Longterm Outcomes After COVID-19
Recruiting NCT05423301 - Global Physiotherapy in ICU Patients With High Risk Extubation Failure N/A
Completed NCT02447692 - Proportional Assist Ventilation for Minimizing the Duration of Mechanical Ventilation: The PROMIZING Study N/A
Completed NCT04016480 - HFNC During Bronchoscopy for Bronchoalveolar Lavage N/A
Completed NCT04507425 - High Flow Nasal Cannula With Noninvasive Ventilation N/A