Clinical Trial Details
— Status: Not yet recruiting
Administrative data
NCT number |
NCT06292728 |
Other study ID # |
ENDOPLY1 |
Secondary ID |
|
Status |
Not yet recruiting |
Phase |
N/A
|
First received |
|
Last updated |
|
Start date |
May 2024 |
Est. completion date |
July 2025 |
Study information
Verified date |
March 2024 |
Source |
ENDOPLY |
Contact |
Jerome Dargent, MD |
Phone |
0033681472286 |
Email |
jerome.dargent[@]polyclinique-rillieux.fr |
Is FDA regulated |
No |
Health authority |
|
Study type |
Interventional
|
Clinical Trial Summary
Prospective, non-randomized study aimed at defining the initial pattern of gastric plication
with the ENDOPLY System, and assess feasibility, ergonomics and safety of the device
Prospective, single-centre, open label, consecutive enrolment
Description:
This is a clinical trial of the ENDOPLY System medical device. Clinical data of 10 obese
patients (obesity grade I and II) will be analysed. The ENDOPLY System medical device will be
used to perform endoscopic internal plication of the stomach. This clinical trial may lead to
an extension of the portfolio of medical devices used to perform endoscopic internal gastric
plication.
Participation in this clinical trial may help individual trial subjects follow a strict diet
that may lead to weight loss. Weight reduction may improve the overall health, quality of
life and life expectancy of the trial subjects, but this cannot be guaranteed.
In this clinical trial, the gastric volume reduction procedure using the ENDOPLY System is
performed under general anaesthesia. Under general anaesthesia, the ENDOPLY Platform is
inserted through the mouth into the oesophagus and upper stomach, after a preliminary
endoscopy for standard evaluation. The 5 mm endoscope allows to choose the initial site of
the plications, most likely and according to similar techniques at the incisura (junction
between the fundus and the antrum). 10 to 15 ligatures will be placed in the upward
directions, thereby narrowing the gastric lumen. The investigator will determine during the
procedure if the experimented device suits the regular pattern of plication that have been
tested over the years in the literature concerning gastric plication.
Gastric volume reduction procedures using the ENDOPLY System may be associated with risks.
There is a possibility of rare or unknown side effects. Risks associated with the
investigational device (ENDOPLY System) - expected gastric fold fibrosis without adverse
local inflammatory reaction. Patients will be administered standard medications as part of
the "Standard of Care" endoscopic gastric examination under general anaesthesia.
Subjects participating in this clinical trial will attend regular follow-up appointments at
1, 3, 6, and 12 months after endoscopic internal plication of the stomach as specified in the
study protocol.
ENDOPLY System technical information:
The ENDOPLY medical device does not contain as an integral part a medicinal substance or a
derivative of human blood or plasma. The ENDOPLY medical device is not manufactured using
tissues of animal origin, in order to minimise the risk of transmission of Transmissible
Spongiform Encephalopathy to human. The ENDOPLY medical device complies with the essential
the requirements laid down for medical devices in conformity assessment under other
legislation governing technical requirements for products, with the exception of those
aspects which are the subject of clinical trial. Precautions have been taken to protect
health and safety with regard to those aspects of the user and the patients. The ENDOPLY
medical device does not have a European Union Certificate for now.
Preliminary tests have included preliminary design-freeze and proof of concept, in-vivo
studies at the Veterinary school of Lyon in 3 pigs, with an autopsy at three months and
pathology samples analysis that have shown the expected fibrosis of gastric folds without
adverse local inflammatory reaction.
ENDOPLY System is made by the company ENDOPLY (Lyon, France). The ENDOPLY System has the same
goal as the other devices achieving an internal gastric plication, means APOLLO System (means
Apollo Endoscopic surgery), ENDOMINA (means comprised of a triangulation platform and an
instrument for tissue piercing and approximation) and Medical's Incisionless Operating
Platform-primary obesity surgery endoluminal procedure). The ENDOPLY System aims at narrowing
the gastric lumen by the mean of separated folds of the internal gastric wall.
The ENDOPLY Platform - Like its competitors, it is an endoscopic tissue approximation device,
with the following parts:
- Handle: it is comprised of two parts that are when the jaws need to be closed.
- The system is made of several channels are put together and assembled within a shaft:
- A 5.6 mm channel for the endoscope (paediatric naso-fibroscope), for the time being.
- A 3 mm channel for the endoscopic grasper.
- A 5 mm channel for the ligature holder.
- The ligature: it consists in a 7 cm plastic barbed special tie made in
Polyetheretherketone (PEEK), with a self-adjusting mechanism (locker) and fits into a
ligature-holder.
- As a secondary step, a box containing reloads will be installed, thus avoiding frequent
in-and-out manipulations. The reload will be also automatized, but those upgrades will
not be available for the trial.
- The extremity of the platform, including delivery catheters outside of the inner
perimeter (that is out of the patient's mouth), has been designed to be ergonomic.