Clinical Trials Logo

Clinical Trial Summary

The aim of this study is to introduce the borescope visually assisted through Fekry oral Intubating airway as a new means of intubation.


Clinical Trial Description

Endotracheal intubation is one of the fundamental skills that should be mastered by the anesthesiologist. One of the important causes of anesthesia related mortality and morbidity is difficult airway related events. A key step in endotracheal intubation is the alignment of the oral, pharyngeal and laryngeal axes. More recently a 2-curve concept has been proposed, involving a primary (oro-pharyngeal curve) and a secondary (pharyngo-glotto-tracheal) curve. The need to align the visual axis to these axes is a common reason for poor visualization of the glottis and the difficulty encountered during endotracheal intubation. Video laryngoscopes (VLS) overcome this problem by allowing the viewer to see the glottis through a camera attached to a curved blade. Several video laryngoscopes (VLS) are available in the market to facilitate endotracheal intubation. These devices are precluded by their cost and availability especially in developing countries. Borescope is an instrument that is used to see through a small hole. The endoscope camera diameter is 5.5 mm and the cable is 1 m long with flexible fiber which could be bended as needed. It is illuminated by circumferentially arranged 6 LED lamps on the head of camera. The other end of cable is connected to Android smart phone (Samsung galaxy S5) which supports OTG (on-the-go) function. Universal Serial Bus (USB) borescopes are commonly used in dental procedures as a dental imaging system. Borescopes are rugged, waterproof and work on trickle power from USB ports of a laptop, computer or a Smartphone. The Smartphone provides the power supply and processes the image. The resultant image can be viewed and recorded in any Smartphone by using a variety of free video capture available applications. The auto detect feature of Smartphones allows the image to appear as soon as the USB device is connected, thus requiring minimal time to set up. As the device is waterproof it can be easily sterilized by soap water and glutaraldehyde. A low-cost VLS ("v-scope") using a straight Miller blade has been tried. The investigators attached an USB borescope to a Miller's blade by waterproof tapes and connected it to a smart phone via an USB-OTG (On the go) cable. Interestingly, it was compared with a conventional Miller blade for intubation and concluded that an ordinary borescope can be used as an effective VLS which is cost effective, easy to assemble and use and can provide acceptable glottis views even in the hands of non-experts. A similar scope was described, but using a Macintosh blade, in February 2016. The device used the video processing capabilities of a personal computer to display real processing present in the ubiquitous smart phone, keeping the initial and recurring costs of the technique low. Since economic consideration is very crucial in developing countries, this study is going to test a safe, low cost technique of visually assisted intubation using the Borescope and Fekry airway instead of the high cost offered by different video laryngoscopes (VLS) available in the market. Fekry airway (Oral Intubating Airway; Egyptian Patent 28118): Several modifications and versions of oro-pharyngeal airways were introduced into the market to facilitate fiberoptic intubation and easy removal of the airway after placement of ETT. Fekry airway is a modification of the Williams airway. The modification made to the Williams airway is that the roof of the proximal cylindrical tunnel is removed thus the airway became open anteriorly. This modification offers the following advantages: it allows easy one step insertion of the tube. Also it facilitates the airway removal after ETT insertion without need to remove the international connection of the ETT. Thus Fekry airway can be easily removed from around the tube while it is connected to anesthesia machine (this reduces the risk of inadvertent ETT dislodgement during airway removal). This study is introducing a novel way to replace the high cost videolaryngoscopy to be used for safe educational purposes and management of difficult airway scenarios. Our hypothesis is that the borescope in association with Fekry oral airway will introduce a new means for low cost, efficient video assisted endotracheal intubation. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05094453
Study type Observational
Source Cairo University
Contact
Status Completed
Phase
Start date June 1, 2020
Completion date July 10, 2021

See also
  Status Clinical Trial Phase
Not yet recruiting NCT05535127 - Sequential Strategy vs Palpation vs Routine Ultrasound for Detection of Cricothyroid Membrane N/A
Not yet recruiting NCT05036460 - Real-time Sonography in Detecting Inadvertent Esophageal Intubation Among Difficult Intubation Patients N/A
Completed NCT05303948 - Evaluation of Two Positions for Free Floating Tracheal Intubation in Weightlessness N/A
Completed NCT06107751 - Ramped and Sniffing Position for Cesarean Section Intubation. N/A
Completed NCT04089540 - New Intubation Method to Achieve Circulatory Stability and to Reduce Number of Intubation Attempts in Neonates N/A
Completed NCT05522049 - Videolaryngoscopic Intubation Using Macintosh vs.Hyperangulated Blades in Patients With Expected Difficult Intubation N/A
Completed NCT03046966 - Manikin To Patient Intubation: Does It Translate? N/A
Not yet recruiting NCT05130645 - Evaluation of Mandibular Mental Angle and Mandibular Profile Angle
Completed NCT06042829 - Impact of Covid-19 Aerosol Box On Intubation Success Rate N/A
Completed NCT06138119 - The Impact of Gender Stereotypes on Fiberoptic Intubation Performance N/A
Not yet recruiting NCT06115694 - Comparison of Video Laryngoscopy With Rigid Stylet vs Video Laryngoscopy With the TCI Articulating Introducer for Endotracheal Intubation in Simulated Difficult Airways N/A
Completed NCT05243758 - Who is Rapid And Success? The Comparison Of Video Fiberscope And Video Laryngoscope N/A
Completed NCT04833166 - Comparing Full vs. Partial Glottis View Using CMAC D-Blade Video Laryngoscope in Simulated Cervical Injury Patient N/A
Completed NCT03118596 - Fibre-optic Guided Tracheal Intubation Through SADs N/A
Recruiting NCT05680909 - Evaluation of SaCo Videolaryngeal Mask Airway in Morbidly Obese
Recruiting NCT05429112 - Flexible Tip Bougie vs Tube With Stylet for Intubation With a Videolaryngoscopy in ICU (VIDEOL-FLEXTIP) N/A
Completed NCT05833347 - Evaluation of Difficult Laryngoscopy With Ultrasonography in Pediatric Patients
Completed NCT05366582 - Neural Integrity Monitor Electromyogram (NIM-EMG) Endotracheal Tube Intubation With Video Laryngoscope N/A
Recruiting NCT06322719 - Hyperangulated vs Macintosh Blades for Intubation With Videolaryngoscopy in ICU N/A
Recruiting NCT06213389 - Comparison of EzVision® Videolaryngoscope and Gum Elastic Bougie-Assisted Machintosh Laryngoscopy N/A