Incisional Hernia Clinical Trial
Official title:
Incisional Hernia Repair by Abdominal Wall Component Release With Contemporary Onlay Mesh Fixation
There is a great expansion in the presentation of complex incisional hernia defects. Primary closure for most cases is impossible with a high rate of recurrence. Component separation provides an autologous repair of the defect but still has considerable recurrence rate. Reinforcement of component separation provides a more strength full repair and may be less recurrence.
the surgical correction was done under general anesthesia. After scrubbing and draping, an elliptical incision was performed . Open the hernia sac then reduce the contents with adhesolysis as required. subcutaneous flaps on both sides were created in a manner that permit to spread an 8 cm mesh after the closure of the abdominal wall. approximate the facia after trimming of its edges with clamps with a manner that allow 1to 2 cm overlap in the midline without tension. In case of tension do selective myofascial advancement (sequential components release). Our steps would be first a unilateral posterior rectus sheath release (1-2 cm longuitodinal incision lateral to linea alba) and reassess, if tension still present, bilateral posterior sheath release should be performed.If tension still present, do a unilateral then bilateral external oblique release as required (1-2 cm lateral to the linea semilunaris along the length of the abdominal wall). close the defect with prolene 1 then cover with onlay wide pore mesh fixation with 2/0 prolene. Close the skin after placement of 2 subcutaneous suction drains. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT06016426 -
Mass Closure vs Layer by Layer Closure
|
N/A | |
Recruiting |
NCT05734222 -
Optimization of Surgical Treatment of Patients With Incisional Ventral Hernias
|
N/A | |
Enrolling by invitation |
NCT03105895 -
Prevention of Incisional Hernia With an Onlay Mesh Visible on MRI
|
N/A | |
Completed |
NCT02089958 -
Standardization of Laparoscopic Hernia Repair
|
N/A | |
Completed |
NCT01961687 -
A Prospective, Multi-Center Study of Phasix™ Mesh for Ventral or Incisional Hernia Repair.
|
N/A | |
Completed |
NCT00998907 -
PDS*Plus and Wound Infections After Laparotomy
|
N/A | |
Terminated |
NCT00498810 -
COMplete Versus PArtial Open inCisional Hernia Repair (COMPAC-TRIAL)
|
N/A | |
Completed |
NCT04961346 -
RCT Comparing Lightweight vs. Heavyweight Meshes in Incisional Hernia Repair
|
N/A | |
Terminated |
NCT03912662 -
ProGripTM Self-Gripping Polyester Mesh in Incisional Hernia Prevention
|
N/A | |
Recruiting |
NCT05620121 -
ACute Treatment of Incisional Ventral Hernia
|
||
Recruiting |
NCT03561727 -
Risk Factors for Development of Incisional Hernia in Transverse Incisions
|
N/A | |
Completed |
NCT03938688 -
Randomized Control Trial Comparing Transfascial Suture for Mesh Fixation to No Mesh Fixation
|
N/A | |
Not yet recruiting |
NCT05568238 -
Vacuum Assisted Wound Closure and Permanent On-lay Mesh-mediated Fascial Traction in Patients With Open Abdomen
|
N/A | |
Not yet recruiting |
NCT02896686 -
Efficacy of an Onlay Mesh for Prevention of Incisional Hernia After Loop Ileostomy Closure
|
Phase 4 | |
Recruiting |
NCT02277262 -
PROPHYlactic Implantation of BIOlogic Mesh in Peritonitis (PROPHYBIOM)
|
Phase 4 | |
Active, not recruiting |
NCT02328352 -
"BP as a New Device for Surgery and Solid Cancer and Hematopoietic System Tumors Treatment. Effects of BP Implantation"
|
Phase 1/Phase 2 | |
Suspended |
NCT01520168 -
Composix Kugel Mesh Recall Leaves Unresolved Problems of Patient Management
|
N/A | |
Completed |
NCT05579652 -
Change in Fascial Tension in Open Abdomens
|
||
Active, not recruiting |
NCT03390764 -
Hernia After Colorectal Cancer Surgery
|
N/A | |
Completed |
NCT02321059 -
Validation of the Goodstrength System for Assessment of Abdominal Wall Strength in Patients With Incisional Hernia
|
N/A |