Clinical Trials Logo

Clinical Trial Summary

This study will evaluate the utilization of an ultra-conservative programming strategy to reduce shocks for ventricular arrhythmias (VA) among patients with heart failure, an implantable cardioverter-defibrillator (ICD) and continuous flow (CF) left ventricular assist device (LVAD). Patients on LVAD support demonstrate unique hemodynamic tolerability of VA, and the role for ICDs among patients with newer generation CF LVADs remains less clear than the older generation devices. Prior studies have explored extended detection ICD programming to reduce unecessary or potentially avoidable shocks to patients. However, no prospective randomized study to-date has evaluated such programming strategies in the CF LVAD patient population. The study hypothesis is that ultra-conservative (UC) ICD programming will result in a reduction of shocks and an improvement in quality of life without increasing hospitalizations, syncope or death among patients on CF LVAD support, and the primary design is a 1:1 randomization between UC programming over standard, physician discretion programming.


Clinical Trial Description

The current International Society for Heart and Lung Transplantation (ISHLT) guidelines provide a class I recommendation for tachy-therapy re-activation in patients with ICDs undergoing LVAD implantation. However, these guidelines reflect a survival benefit observed in cohorts comprised primarily of older-generation pulsatile flow LVADs. While the overall VA prevalence in the LVAD population exceeds 50% with VA usually occurring >200 beats per minute, VA are generally well-tolerated both hemodynamically and symptomatically. Observed LVAD flows do decrease during sustained VA but there are multiple case reports of LVAD patients remaining awake and asymptomatic despite hours of ventricular fibrillation and a large case series reported no deaths and rare syncope due to VA in CF LVAD patients. Contrary to guidelines, contemporary evaluations restricted to CF LVADs show no clear ICD survival benefit in single center studies nor a large, pooled meta-analysis. In fact, propensity-matched analyses of CF LVAD patients in the INTERMACS and UNOS registries have demonstrated increased mortality and more hospitalizations among patients with an active ICD and treated VA. It is unclear in the CF LVAD population whether ICD shocks themselves are harmful or rather identify a higher-acuity patient subgroup. In the general HF population, however, shocks have consistently been associated with worse outcomes. Shock reduction programming resulted in reduced mortality in the MADIT-RIT trial, suggesting shocks may be directly harmful and not only a marker of substrate. Therefore, the present study will evaluate whether ultra-conservative (UC) programming for ICDs can reduce shocks over standard (physician-discretion) programming among patients with heart failure on CF LVAD support. The model is 1:1 randomization between the two programming strategies for patients with newly implanted CF LVAD devices and a pre-existing ICD. They will be eligible for enrollment during their index hospitalization, and after discharge up to their first outpatient follow-up visit no later than 3 months post discharge. The primary endpoints will be any ICD shock, all-cause mortality, and syncope. The secondary endpoints will be time to first ICD shock, time to first ICD shock for VT/VF, quality of life questionnaire and hospitalizations, including for heart failure and ventricular arrhythmias. The principal exclusion criteria will be pediatric patients, or those without a functional ICD system. Standard of care follow-up will continue thru 24 months. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04264182
Study type Interventional
Source The Cleveland Clinic
Contact
Status Terminated
Phase N/A
Start date February 3, 2020
Completion date April 4, 2022

See also
  Status Clinical Trial Phase
Withdrawn NCT03227393 - The Effect of Yoga on Cardiac Sympathetic Innervation Evaluated by I-123 mIBG N/A
Recruiting NCT04528004 - Mechanistic Studies of Nicotinamide Riboside in Human Heart Failure Early Phase 1
Recruiting NCT04703842 - Modulation of SERCA2a of Intra-myocytic Calcium Trafficking in Heart Failure With Reduced Ejection Fraction Phase 1/Phase 2
Recruiting NCT04522609 - Electrostimulation of Skeletal Muscles in Patients Listed for a Heart Transplant N/A
Completed NCT05475028 - Network Medicine Approaches to Classify Heart Failure With PReserved Ejection Fraction by Signatures of DNA Methylation and Point-of-carE Risk calculaTors (PRESMET)
Not yet recruiting NCT05988749 - Digital Remote Home Monitoring for Heart Failure N/A
Not yet recruiting NCT06240403 - Digoxin and Senolysis in Heart Failure and Diabetes Mellitus Phase 2
Recruiting NCT04950218 - The Psoriasis Echo Study
Suspended NCT04701112 - Acute Hemodynamic Effects of Pacing the His Bundle in Heart Failure N/A
Completed NCT03305692 - ECG Belt vs. Echocardiographic Optimization of CRT N/A
Recruiting NCT05933083 - MCNAIR Study: coMparative effeCtiveness of iN-person and teleheAlth cardIac Rehabilitation N/A
Enrolling by invitation NCT03903107 - The Fluoroless-CSP Trial Using Electroanatomic Mapping N/A
Withdrawn NCT04872959 - TRANSFORM Heart Failure With Reduced Ejection Fraction N/A
Completed NCT02920918 - Treatment of Diabetes in Patients With Systolic Heart Failure Phase 4
Completed NCT02334891 - Kyoto Congestive Heart Failure Study
Recruiting NCT03553303 - Pharmacodynamic Effects of Sacubitril/Valsartan on Natriuretic Peptides, Angiotensin and Neprilysin Phase 4
Recruiting NCT04083690 - Multi-lead ECG to Effectively Optimize Resynchronization Devices: New CRT Recipients N/A
Recruiting NCT03830957 - Efficacy and Safety of Ivabradine to Reduce Heart Rate Prior to Coronary CT-angiography in Advanced Heart Failure: Comparison With β-Blocker N/A
Recruiting NCT06121323 - Physiological Effects of Lactate in Individuals With Chronic Heart Failure N/A
Completed NCT03351283 - Effect of Sodium Intake on Brain Natriuretic Peptide Levels in Patients With Heart Failure N/A