View clinical trials related to Hemodynamics.
Filter by:Microcirculatory dysfunction appears to play a key role in the development of organ failure leading to the death of patients with coronavirus disease 2019 (Covid-19). It is still uncertain today whether this damage is secondary to direct viral infection of endothelial cells or the consequence of the inappropriate inflammatory response induced by the infection. The analysis of endothelial and microcirculatory dysfunctions and glycocalyx degradation therefore appears to be necessary in the understanding of the pathophysiological mechanisms of Covid sepsis and could play a role in the evaluation of the efficacy of certain therapeutics which would aim at improving regional perfusion by decreasing microcirculatory dysfunction.However, the analysis of microcirculatory failure, endothelial dysfunction and glycocalyx degradation has so far only been evaluated in small cohorts, without quantitative analysis of microcirculatory perfusion
To perform CT-QFR, invasive coronary angiography, FFR, and QFR tests on patients with moderate coronary stenosis after coronary CTA examination. Use FFR as a reference to verify the diagnostic performance of CT-QFR, and compare it with QFR.
Propofol is one of the most widely used anesthetics for its fast onset and quick elimination. The conventional speed of its induction dose often causes severe hemodynamics fluctuations with hypotension and arrhythmia. The recommended dosage on the drug insert comes from group pharmacokinetic studies which does not apply to the specific situation of every patient, so the investigators emphasize individualized medication. The investigators have observed the titration of propofol in general anesthesia induction, and found that the dosage was less and the hemodynamics was becoming more stable. At the same time, the investigators found that the hemodynamics still has obvious fluctuations in the titration of the administration rate recommended in the instructions. The investigators intend to further compare the effects of propofol titration administration at different rates for hemodynamics and stress during the induction period of general anesthesia, and find a safer and more appropriate rate of administration.
Ballistocardiographic (BCG) biosensors reflecting the patients' current state is established. There are few studies documenting BCG biosensors efficacy, effectiveness, and efficiency. In addition, technologies using invasive blood pressure curves and Near Infrared Regional Spectrometry (NIRS) to measure hemodynamics have been used. Using these technologies to guide clinical decisions may be an major advance for patients with acute and chronic diseases. The investigators will explore how these technologies compares to well established technologies measuring vital signs of healthy subjects. The investigators will use live continuous and non-continuous biosensor data to monitor the development of vital parameters during different scenarios. The study will document how CPD measured by biosensors, cerebral oximetry measured by NIRS, and invasive blood pressure curves measured by FloTracâ„¢ are compared to established technologies of vital organ functionality. Data will be measured continuously and documented simultanuously with technologies such as Doppler Echocardiography, transthoracic impedance (TTI), Electrocardiogram (ECG), invasive blood pressure [cardiac output/index (CO/CI), stroke volume/stroke volume index (SV/SVI), stroke volume variation/pulse pressure variation (SVV/PPV), systemic vascular resistance/ systemic vascular resistance index (SVR/SVRI), mean arterial pressure (MAP)], pulse oximetry (SpO2) and cerebral oximetry (rSO2). Of special interest is to document how relative heart stroke volume reflects blood flow documented by the parallel technology measures. All these measures are the key part in the study to document user friendliness, accuracy, sensitivity, specificity and correlations. The main research question is whether adding BCG biosensor measures, cerebral oximetry and invasive blood pressure to monitor vital signs will add meaningful information to the care of patients in a situation where we are able to control all the factors that may impact these measures. The aim of the study is to document (correlation, sensitivity and specificity) how BCG biosensors perform compared to each other and to well established technologies used for monitoring blood flow, blood pressure, heart rate and respiration rate in steady state and during ambulance transport. In addition, the investigators will in a controlled manner measure how established maneuvers like Trendelenburg, hypo-/hyperventilation, and bolus of fluid influences our measures.
To investigate the influence of PEEP (Positive end-expiratory pressure), changes in preload (patient position) and changes in afterload (phenylephrine) on ultrasound measures of renal perfusion in patients after uncomplicated cardiac surgery. To investigate the effects of phenylephrine on both invasive measures of the systemic- and pulmonary circulation and, secondarily, to assess the induced changes in echocardiographic indices of left- and right ventricular systolic- and diastolic function.
Lack of patient knowledge about ECT (electroconvulsive therapy) is a leading cause of treatment fear with 60% of ECT patients reporting high levels of anxiety. The purpose of this study is to determine if using Virtual Reality (VR) to allow patients' to experience a virtual ECT education session before treatment is useful in lowering treatment anxiety and increasing knowledge about ECT if compared to standard treatment. In addition, measuring heart rate and blood pressure levels before ECT treatment will allow us to assess changes in anxiety levels. Individuals who choose to participate will be placed (participant will have a 50% chance to be placed in either group) to view either a virtual reality video to experience a virtual ECT session, or to receive standard preparation, i.e. a discussion with a psychiatrist. Before and after this session participants will be asked to complete a measurement of their anxiety level and knowledge about ECT (ECT Attitude & Knowledge Questionnaire). Just before ECT treatment, blood pressure, heart rate and anxiety level will be measured. Participants will also complete cognitive and depression assessments. This study will help to develop a relationship between healthcare providers and patients and their families to help with education before ECT treatment.
Advances in endoscopic equipment and technique have led to the use of minimally invasive thoracic surgery in an increasing number of pediatric surgical procedures. Logically, thoracoscopic surgery and anesthesia can induce significant physiologic changes,, derangements of normal respiratory physiology induced by the surgical approach and the installation of carbon dioxide into the thoracic cavity can lead to alterations of normal acid-base status. Finally, surgical procedures in the chest, surgical traction or insufflation pressures impairs venous return and/or cardiac function, especially in neonates and infants. In this study Electrical Cardiometry TM (ICON, Cardiotronic/Osypka Medical, Inc., La Jolla CA, USA) is used assess the effect of different intra-thoracic pressure (insufflation pressures 4,5 & 6 mmHg) during thoracoscopic surgeries in neonates and infants on hemodynamics using electrical velocimetry (ICON) as non-invasive monitoring technique.
Multicenter randomised study which aims to compare sutureless Vs. standard bio- prostheses (1:1) among patients undergoing surgical aortic valve replacement in terms of: - 6 -month hemodynamic performance. - 6 month clinical outcomes including all cause mortality, stroke, myocardial infarction, valve reoperation and major/life threatening bleeding - Cost effectiveness
Background: Impedance cardiography (ICG) is a noninvasive method for continuous left cardiac output monitoring based on measurement of thoracic electrical bioimpedance. The objective of this study is to validate an ICG device by investigating the agreement in cardiac output (CO; left ventricular output x heart rate) measurements performed by ICG and echocardiography. The ICG device (PhysioFlow) has a new filter technology reducing signal noise and enabling measurements in patients who are moving freely. Material and Methods - Design: Prospective observational study. - Inclusion: 30 healthy term infants between 24 and 48 hours of age, after parental consent - Methods: Continuous measurement with ICG over a 30 min period and point of care echocardiography - Primary outcome: Agreement (bis and precision) between measurement of CO with ICG and echocardiography. - Secondary outcomes: Agreement between other echocardiographic indices of myocardial function and ICG parameters (early diastolic filling ratio, cardiac index, ventricular ejection time and left cardiac work index). - Statistics: Agreement between ICG and echocardiography data will be evaluated using Bland-Altman statistics, including the calculation of mean bias (average difference between measurements) with corresponding standard deviation and lower and upper limits of agreements (95% confidence interval).
To compare the efficacy of Levosimendan versus Milrinone in supporting hemodynamics during off-pump coronary artery bypass grafting surgery in patients with low ejection fraction.