Official title:
A Validation Study of the 3D-CoPS and 3D-CoRS and Its Relationship With an International Acknowledged Assessment Tool (ETS) in Simulated Colonoscopy
A cross validation study comparing an international acknowledged assessment tool "Endoscopy
Training System" (ETS) and movement analysis of the colonoscope based on raw data from coils
within the scope.
24 physicians are recruited and divided based on experience (novices and experienced). All
participants are to perform twice on the ETS that is based on four tasks; Scope manipulation,
tool targeting, loop management and mucosal inspection. The movement of the colonoscope will
be gathered during the tasks and correlated to the scores of the ETS.
24 physicians are recruited on a voluntarily basis, and will be divided into two groups,
based on experience;
1. 12 Novices (0-50 colonoscopies)
2. 12 Experienced (> 140 colonoscopies). The groups are to perform twice on the Endoscopy
Training System that is based on four tasks; Scope manipulation, tool targeting, loop
management and mucosal inspection. Data for 3D-Colonoscopy Retraction Score (3D-CoRS)
will be gathered during the task of mucosal inspection and data for 3D-Colonoscopy
Progression Score (3D-CoPS) are collected during loop management.
Novice group:
Any physician who has no experience of endoscopies or has done no more than 50 colonoscopies.
Experienced group:
Includes any physician who have succeeded more than 140 colonoscopies. Professional
backgrounds include surgeons and gastroenterologists.
Demographic data will gathered from all three groups as follows:
- Age
- Sex
- Speciality
- Total number of colonoscopies
- Total number of colonoscopies the last year
- Time since graduation
- Experience in simulated endoscopy/colonoscopy The Endoscopy Training System is a
simulation system and an assessment tool and includes five different performance metrics
and a scoring system. The system is used in combination with an Olympus colonoscope
(Olympus Medical Systems Corp. Tokyo, Japan).
Performance metrics:
1. Scope Manipulation (SM) - The use of torque and tip deflection to move a shape in the
colon to the 6 o´clock position and align the same shape within an outline placed upon
the monitor screen. Before continuing to the next shape, alignment must be held for 5
seconds.
2. Tool Targeting (TT) - 10 targets located around the colon must be found. With a biopsy
forceps, each target has to been touched for at least 5 seconds before moving to the
next target.
3. Loop Management (LM) - The management of a standard alfa-loop. If during insertion from
anus until cecum a loop is formed, it must be first recognised and then unlooped
successfully to continue advancing the colonoscope.
The Colonoscopy Training Model begin in the left lateral position, but on request, the
model can be repositioned in the supine, prone, or right lateral decubitus position. On
request, abdominal pressure can be provided when directed by the participant.
4. Mucosal Inspection (MI) - Randomly placed polyps inside the rubber colon have to be
found during withdrawal, requiring inspection and retroflexion in the rectum.
5. Retroflexion (RF) - 5 targets located around the anus must be found. With a biopsy
forcep, each target has to been touched while the colonoscope is retroflexed in the
rectum and touched for at least 5 seconds before moving to the next target.
The 3D-Colonoscopy Progression Score (3D-CoPS) and the 3D-Colonoscopy Retraction Score
(3D-CoRS) are movement analysis. Electromagnetic coils are built in along the length of the
Olympus colonoscopes. They generate a pulsed low-intensity magnetic field that is picked up a
receiver coil. The data-points for each coil are inserted into an algorithm for movement
analyzing. This analysis is done as a change between the tip of the scope, and the next
tracked magnetic coil. The result is a relative movement of the colonoscope in relation to
the previous position, and how much the movement is deflected according to the direction the
tip points in. This movement analysis is used for distinction between the progression- and
retraction phase, and as the basis for the 3D-CoPS and 3D-CoRS analysis, which is essential,
such that the 3D-CoRS measurements is performed during withdrawal of the colonoscope.
;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT04083924 -
Preclinical Medical Student Echocardiography Training American Society of Echocardiography Curriculum
|
N/A | |
Completed |
NCT05013476 -
Tele-Ultrasound: VIrtual Hands-on Education for Novice Users
|
N/A | |
Completed |
NCT03436589 -
The Indiana SNAP-Ed Long-term Study
|
N/A | |
Completed |
NCT03678077 -
Trends in Cohabitation Status, Academic Achievement and Socio-economic Indicators After Mild Traumatic Brain Injury
|
||
Completed |
NCT05007704 -
Competencies Required by Anesthesiologists Managing Critically Ill Patients
|
||
Completed |
NCT04082845 -
Effect of Web-Based Training With Thyroidectomy Patients
|
N/A | |
Completed |
NCT05335759 -
Coaching Programme for Preceptorship of Undergraduate Nurses' Students
|
||
Not yet recruiting |
NCT04959045 -
The Effect of Flipped Classroom Teaching Method on Academic Achievement and Skill Learning Level in Skills Education
|
N/A | |
Enrolling by invitation |
NCT03587233 -
Are Women With Higher Professional Status More Sedentary Compared to Men?
|
N/A | |
Recruiting |
NCT05086783 -
Video-based Coaching (VBC) in Gynecologic Surgery
|
N/A | |
Completed |
NCT06046378 -
The Effect of Digital Stories Prepared With Digital Audio File (Podcast) on Midwifery Learning
|
N/A | |
Completed |
NCT04186390 -
Learning Small Bowel Capsule Endoscopy
|
||
Recruiting |
NCT02377908 -
European Postgraduate Training in Geriatric Medicine
|
N/A | |
Terminated |
NCT01720017 -
Impact of Manikin Training on Airtraq Avant Learning Curve in Predicted Difficult Airways
|
N/A | |
Completed |
NCT01001286 -
Questscope Non-Formal Education Impact Study
|
Phase 2 | |
Withdrawn |
NCT00425295 -
Effectiveness of Human Simulation Training for Medical Crisis Management Skills
|
Phase 1 | |
Completed |
NCT00887185 -
Validation/Dissemination Of A Temporal Bone Dissection Simulator
|
Phase 2 | |
Completed |
NCT04343352 -
Evaluation of the Efficiency of Mobile Application for Parents of Children With Epilepsy
|
N/A | |
Not yet recruiting |
NCT06091462 -
Virtual Reality and Nursing Students and Dementia
|
N/A | |
Completed |
NCT05974943 -
The Effect of Problem Solving and Decision Making Training Given to Nurses Managers
|
N/A |