Clinical Trials Logo

Clinical Trial Summary

The Cross Cancer Institute has recently acquired a tomotherapy radiotherapy treatment machine; the first of its kind in Canada. It has the potential to improve cancer treatment outcomes where radiotherapy is used. Cervix cancer is a disease where radiotherapy is a particularly important treatment modality. The researchers believe that by combining tomotherapy (which has the ability to give higher doses of radiation to areas of cancer while sparing normal tissues) with radiotherapy given from inside the uterus and vagina (brachytherapy) disease outcomes will be improved. For this to be possible the researchers will need to accurately map the doses of radiation given to the cervix, uterus and other pelvic organs from these two types of radiation treatment. As well as being used for treatment, the tomotherapy machine can also be used for taking medical images by using very much lower doses of radiation. This study will allow the researchers to develop the mapping process by using very low doses of radiation on the tomotherapy unit to take medical x-ray images of patients being treated by brachytherapy for cervix cancer. In this special circumstance the researchers expect the images to be of a higher quality than for conventional computed tomography (CT) scanning or magnetic resonance imaging (MRI) scanning.


Clinical Trial Description

Megavoltage CT Imaging for Intracavitary Radiation Treatment in Cervix Cancer

Proposal

To assess the feasibility of performing CT imaging using a megavoltage CT scanner on five patients where remote afterloading intracavitary applicators have been inserted for the purpose of delivering intracavitary radiotherapy in the treatment of cervix cancer.

Rationale

While there has been recent improvements in the treatment of more advanced stages of cervix cancer by combining radical radiation treatment with concurrent cisplatin based chemotherapy, there is room for further improvements in local regional control. One approach to achieving this is to increase the dose of therapeutic radiation to the clinical target volume without exceeding the tolerance of the adjacent normal tissues. Modern radiotherapy techniques allow for better conformation of the high dose radiation volume to the clinical target volume by using external beam techniques (conformal radiation treatment and intensity modulated radiation treatment) and the use of tomotherapy is likely to be particularly advantageous in this regard. The mainstay of cervix cancer radiotherapy has always been and will likely remain the use of brachytherapy. Future improvements in the outcome of cervix cancer treated by radiotherapy are therefore likely to necessitate accurately combining intracavitary radiation treatment with intensity modulated external beam radiation treatment and particularly with the use of tomotherapy techniques.

The ability to accurately reconstruct the three-dimensional dosimetry achieved by the combined use of intracavitary radiation treatment and helical tomotherapy will be pivotal in the success of this strategy. Conventional CT imaging of patients receiving intracavitary radiation treatment is hampered by distortion artifacts from the metallic applicators. The opportunity to gain improved images using megavoltage CT scanning using the same equipment and same patient set-up that will ultimately by used for the delivery of tomotherapy offers some unique potential advantages and solutions to the problem.

By imaging patients with the remote afterloading applications in situ, the researchers should be able to generate accurate isodose distributions in three dimensions for the intracavitary component of the cervix cancer treatment. By contouring the clinical target volume, which includes the primary cancer, local routes of spread and regional pelvic lymph nodes, the researchers can explore the feasibility of generating combined helical tomotherapy and intracavitary radiation treatment plans.

Patients and Methods

Patients who are to receive intracavitary brachytherapy on the low dose rate selectron at the Cross Cancer Institute will be approached to participate in this pilot study. An informed consent will be obtained from five patients for this study. Following the insertion of the remote afterloading applicators in the operating room, patients are normally transferred from the operating room to Simulator C for orthogonal simulator films and then to Station 30 where treatment is started approximately two hours later after dosimetry calculations have been performed and treatment has been prescribed.

For the patients consenting to this study, they will proceed from Simulator C to Station 30 via the tomotherapy unit in CBIAR where megavoltage CT scans will be taken. Patients will be accompanied by a brachytherapy radiation therapist. The megavoltage CT scans will take approximately one hour to perform, but this will not result in any treatment delay for the patient.

Isodose volumes from the prescribed intracavitary brachytherapy will be reconstructed on the megavoltage images. The feasibility of defining the clinical target volume on the megavoltage scans will be explored. This may require fusion with conventional CT images that will already have been taken for diagnostic and external beam treatment planning purposes. Megavoltage and/or fused images will be used to pilot the integration of tomotherapy intensity modulated radiation therapy treatment plans with intracavitary brachytherapy dosimetry.

The current study will have no influence on individual patient treatments but is a prelude to a potential dose escalation study using tomotherapy for patients with cervix cancer. ;


Study Design

Observational Model: Case-Only, Time Perspective: Prospective


Related Conditions & MeSH terms


NCT number NCT00124423
Study type Observational
Source AHS Cancer Control Alberta
Contact
Status Completed
Phase N/A
Start date June 2004
Completion date June 2007

See also
  Status Clinical Trial Phase
Recruiting NCT04067882 - Validation of the Genetic Signature 354849 as a Prognostic Method
Completed NCT00329589 - A Trial Using Velcade Plus Chemoradiation for Central Nervous System, Head and Neck, and Cervical Cancer Patients Phase 1
Recruiting NCT05743517 - Physical Activity Intervention Among Older Women With Gynecologic Cancers (Fit4Treatment) N/A
Completed NCT05234112 - Prevention and Screening Towards Elimination of Cervical Cancer N/A
Completed NCT04258553 - Thiol Disulfide Balance in Cervix Cancer
Completed NCT03956498 - Impact of a Sexological Follow-up on the Sexual Function in Patients With Cervix or Vaginal Cancer Treated by Radiotherapy and Brachytherapy N/A
Active, not recruiting NCT04357873 - Efficacy of Immunotherapy Plus a Drug in Patients With Progressive Advanced Mucosal Cancer of Different Locations Phase 2
Completed NCT00379743 - Partnership for Healthy Seniors N/A
Completed NCT00509444 - Cancer Prevention and Treatment Among African American Older Adults: Treatment Trial Phase 3
Recruiting NCT06022029 - A Dose Escalation and Dose Expansion Study of Intratumoral ONM-501 Alone and in Combination With Cemiplimab in Patients With Advanced Solid Tumors and Lymphomas. Phase 1
Recruiting NCT06116019 - Online Adaptive Radiotherapy Using a Novel Linear Accelerator (ETHOS)
Completed NCT04072913 - Matrix Metalloproteinases and Human Papillomavirus in Dysplasias and Cancers of the Cervix N/A
Active, not recruiting NCT06452004 - Validation of Artificial Intelligence as Decision Support System in VIA (PRESCRIP-TEC) N/A
Recruiting NCT04651127 - Anti-PD-1 Antibody Combined With Histone Deacetylase Inhibitor in Patients With Advanced Cervical Cancer Phase 1/Phase 2
Recruiting NCT06010875 - A Clinical Research About CD70-targeted CAR-T in the Treatment of CD70-positive Advanced/Metastatic Solid Tumors Phase 1
Completed NCT02552121 - Tisotumab Vedotin (HuMax®-TF-ADC) Safety Study in Patients With Solid Tumors Phase 1/Phase 2
Completed NCT02001623 - Tisotumab Vedotin (HuMax®-TF-ADC) Safety Study in Patients With Solid Tumors Phase 1/Phase 2
Completed NCT02997553 - Fluorescence for Sentinel Lymph Node Identification in Cancer Surgery Phase 3
Terminated NCT02233387 - PET CT With HX4 in Cervix Cancer Phase 2
Completed NCT01766284 - Study of the Diagnostic Efficacy of "Real Time" Niris 1300e Optical Coherence Tomography (OCT) Imaging System in the Management of Pre-invasive and Invasive Neoplasia of the Uterine Cervix N/A