Cataract Clinical Trial
Official title:
Comparison of Operating Room Toric Placement Tools, CALLISTO Eye vs. Wavetec AnalyzOR (CORTCO)
The goal of this clinical trial is to evaluate two separate operating room cataract measuring tools in predicting the residual astigmatism (prediction error) in patients with corneal astigmatism. The main question it aims to answer is: Show the refractive predictability comparing the use of Operating Room cataract toric lens placement tools against the standard manual technique. Participants will be implanted with the TECNIS Toric II IOL Lens Model ZCU; the second eye, if applicable, is to be implanted within 45 days of the first-eye surgery. Researchers will compare two Operating Room cataract lens placement tools: the Zeiss CALLISTO vs. the Wavetec AnalyzOR to determine refractive predictability.
To evaluate two separate operating room cataract measuring tools in predicting the residual astigmatism (prediction error) in patients with corneal astigmatism (maximum allowable up to 3.0D) comparing the ZEISS CALLISTO eye and the Wavetec AnalyzOR at the one-month post-operative visit. Both surgery rooms will be using Veracity, IOL Master and Zeiss Opmi Lumera i Operating Room Microscopes. Operating Room #1 will be utilizing the ZEISS CALLISTO eye for axis alignment, along with Veracity and IOL Master for lens selection, and Operating Room #2 will be utilizing the Wavetec AnalyzOR for lens selection and axis alignment. Procedure times for the ZEISS CALLISTO eye and the Wavetec AnalyzOR will be obtained by using a start/stop watch, including phakic power calculation and toric positioning. In addition, the suction on (start of LenSx), treatment time of LenSx in seconds, suction off (end of LenSx), start time of primary incision, the beginning of Phaco, end of phaco, CDE (Combined Diffused Energy) total and the end time of procedure will all be documented. All times will be analyzed and compared between Operating Room #1 and Operating Room #2. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT04685538 -
Chloroprocaine 3% Gel Eye Drop as Topical Anestheticsin Phacoemulsification.
|
Phase 3 | |
Recruiting |
NCT06060041 -
IC-8 Apthera IOL New Enrollment Post Approval Study
|
||
Recruiting |
NCT05518539 -
Evaluation of Quality of Vision and Visual Outcomes With Bilateral Implantation of the Clareon PanOptix Intraocular Lens
|
||
Recruiting |
NCT05271942 -
Tilt and Tumble vs Divide and Conquer - a Unique Comparison of the Two Cataract Surgery Methods
|
N/A | |
Active, not recruiting |
NCT04778501 -
PMCF Study on Monofocal Toric IOL (PODEYE TORIC) in Asia
|
N/A | |
Completed |
NCT05062564 -
Efficacy of LipiFlow in Patients Affected by Meibomian Gland Dysfunction in Reducing Post-cataract Surgery Dry Eye
|
N/A | |
Completed |
NCT03751033 -
Influence of DisCoVisc Ophthalmic Viscosurgical Device (OVD) on Intraoperative Aberrometry Readings
|
N/A | |
Completed |
NCT02529488 -
Investigation of AcrySof® IQ PanOptix™ Presbyopia-Correcting Intraocular Lens (IOL) Model TFNT00
|
N/A | |
Completed |
NCT04539548 -
A Study Assessing the Safety and Efficacy of Dextenza® for the Treatment of Ocular Pain and Inflammation Following Surgery for Pediatric Cataract
|
Phase 3 | |
Completed |
NCT03740659 -
Evaluation Of Aqueous Humor Of Levofloxacin-Dexamethasone Eye Drops And Of Its Components In Patients Undergoing Cataract Surgery
|
Phase 2 | |
Completed |
NCT03494257 -
Effect of Fixed Brinzolamide-brimonidine Combination on Intraocular Pressure After Phacoemulsification
|
N/A | |
Completed |
NCT05119127 -
Rotational Stability of Acrysof IQ Vivity Extended Vision Toric IOL and Refractive Visual Outcome.
|
N/A | |
Active, not recruiting |
NCT04271709 -
Manhattan Vision Screening and Follow-Up Study (NYC-SIGHT)
|
N/A | |
Recruiting |
NCT03713268 -
Intraoperative OCT Guidance of Intraocular Surgery II
|
||
Completed |
NCT03739528 -
Levo-Dexa vs. Tobra+Dexa for Prevention and Treatment of Inflammation and Prevention of Infection in Cataract Surgery
|
Phase 3 | |
Completed |
NCT02888210 -
A Study Assessing Safety and Efficacy of MD-15 Intraocular Lens in Patients With Aphakic Eye After Cataract Surgery
|
Phase 3 | |
Completed |
NCT03356847 -
Evaluation of the Rotational Stability of the Monofocal SISA Implant Following Cataract Surgery
|
N/A | |
Completed |
NCT04332640 -
Clinical Evaluation of the Next Generation Phaco System
|
N/A | |
Recruiting |
NCT03638726 -
Subconjunctival Atropine and Intracameral Epinephrine for Pupil Dilation in Phacoemulsification
|
Phase 4 | |
Completed |
NCT03050697 -
Evaluation of the Safety and Performance of the HARMONI® Toric Lens
|
N/A |