Cataract Clinical Trial
Official title:
A Comparison of the Diagnostic Confidence and Image Quality Between the Eyoto Theia (RDSL) Remote Digital Slit Lamp and a the Topcon SL-D2 With DC-4 Digital Attachment (Predicate Device).
A clinical study has been identified as a requirement for the RDSL (Theia). This study involves a clinical comparison of the imaging from the RDSL with that of a predicate device. The clinical evaluation showed that there remains some residual risk in the practitioner's ability to use the imaging from the RDSL to detect pathologies at the same level as when using the imaging function on a predicate device. The aim of this comparative study is to determine the degree, if any, of difference in using images captured from the RDSL for clinical inspection of pathologies, when compared to images captured from a predicate device. Due to the involvement of real patients during the study, ethics approval was sought prior to commencement. This study is limited to the clinical benefits of the device. An additional Human factors study has been conducted to assess the useability of the device Images were taken of healthy eyes and eyes with pathology (with images of several pathologies from each major pathology group to give a full range) on both the predicate device, and the RDSL.
Methodology Overview Images were taken of 14 healthy eyes and 35 unhealthy eyes containing a range of pathologies on both the predicate device and the THEIA. The pathologies to be imaged have been carefully selected using data from the clinical evaluation, and further investigation, to ensure that all aspects of the imaging systems and ocular structures are included. The images were taken on compliant patients in a real-world setting. Device Selection Device Type:AC-powered remote enabled slit-lamp Manufacturer:Eyoto Product Number:THEIA (3-008-0001-03) Intended Use: The THEIA is intended for non-invasive examination, illumination, magnification, visualization and recording of digital photographs and video of the anterior and posterior eye segments of the human eye and its surrounding area. Magnification:6 (base Magnification), 10X, 16X, 25X (digital steps) Filters:Blue filter,Red-free filter (digital filter),yellow Filter (fluorescein enhancement filter) Lighting:White LED,12 V, 0.7 - 1.5 A, 8.4 W Image Sensor,CMOS, 1.1", 12 Megapixel The latest pre-production version of the THEIA was used. This is representative of and has all the same functionality as, the production model. Three individual THEIA devices of the same version were used to collect the images. Predicate Device Device Type:AC-powered slit lamp biomicroscope Manufacturer:Topcon Product Number:Topcon SL-2G or equivalent (SL-2D with imaging attachment) Intended Use:The Slit Lamp SL-2G is an AC-powered slit lamp biomicroscope intended for use in eye examination of the anterior eye segment, from the cornea epithelium to the posterior capsule. It is used to aid in the diagnosis of diseases or trauma which affect the structural properties of the anterior eye segment. Magnification:10X, 16X, 25X Filters:Blue filter, Red-free filter, Yellow Filter (fluorescein enhancement filter) available as an accessory Lighting:White LED Image Sensor (DC-4):CMOS, 5 Megapixel The predicate device used for this study was equivalent to the Topcon SL-2G used in the substantial equivalence investigation, used with the recommended Topcon Digital Imaging Adaptor (DC-4) in order to take the images required. Three individual predicate devices will be used to collect the images. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT04685538 -
Chloroprocaine 3% Gel Eye Drop as Topical Anestheticsin Phacoemulsification.
|
Phase 3 | |
Recruiting |
NCT06060041 -
IC-8 Apthera IOL New Enrollment Post Approval Study
|
||
Recruiting |
NCT05518539 -
Evaluation of Quality of Vision and Visual Outcomes With Bilateral Implantation of the Clareon PanOptix Intraocular Lens
|
||
Recruiting |
NCT05271942 -
Tilt and Tumble vs Divide and Conquer - a Unique Comparison of the Two Cataract Surgery Methods
|
N/A | |
Active, not recruiting |
NCT04778501 -
PMCF Study on Monofocal Toric IOL (PODEYE TORIC) in Asia
|
N/A | |
Completed |
NCT05062564 -
Efficacy of LipiFlow in Patients Affected by Meibomian Gland Dysfunction in Reducing Post-cataract Surgery Dry Eye
|
N/A | |
Completed |
NCT03751033 -
Influence of DisCoVisc Ophthalmic Viscosurgical Device (OVD) on Intraoperative Aberrometry Readings
|
N/A | |
Completed |
NCT02529488 -
Investigation of AcrySof® IQ PanOptix™ Presbyopia-Correcting Intraocular Lens (IOL) Model TFNT00
|
N/A | |
Completed |
NCT04539548 -
A Study Assessing the Safety and Efficacy of Dextenza® for the Treatment of Ocular Pain and Inflammation Following Surgery for Pediatric Cataract
|
Phase 3 | |
Completed |
NCT03740659 -
Evaluation Of Aqueous Humor Of Levofloxacin-Dexamethasone Eye Drops And Of Its Components In Patients Undergoing Cataract Surgery
|
Phase 2 | |
Completed |
NCT03494257 -
Effect of Fixed Brinzolamide-brimonidine Combination on Intraocular Pressure After Phacoemulsification
|
N/A | |
Completed |
NCT05119127 -
Rotational Stability of Acrysof IQ Vivity Extended Vision Toric IOL and Refractive Visual Outcome.
|
N/A | |
Active, not recruiting |
NCT04271709 -
Manhattan Vision Screening and Follow-Up Study (NYC-SIGHT)
|
N/A | |
Recruiting |
NCT03713268 -
Intraoperative OCT Guidance of Intraocular Surgery II
|
||
Completed |
NCT03739528 -
Levo-Dexa vs. Tobra+Dexa for Prevention and Treatment of Inflammation and Prevention of Infection in Cataract Surgery
|
Phase 3 | |
Completed |
NCT02888210 -
A Study Assessing Safety and Efficacy of MD-15 Intraocular Lens in Patients With Aphakic Eye After Cataract Surgery
|
Phase 3 | |
Completed |
NCT03356847 -
Evaluation of the Rotational Stability of the Monofocal SISA Implant Following Cataract Surgery
|
N/A | |
Completed |
NCT04332640 -
Clinical Evaluation of the Next Generation Phaco System
|
N/A | |
Recruiting |
NCT03638726 -
Subconjunctival Atropine and Intracameral Epinephrine for Pupil Dilation in Phacoemulsification
|
Phase 4 | |
Completed |
NCT03050697 -
Evaluation of the Safety and Performance of the HARMONI® Toric Lens
|
N/A |