Cataract Clinical Trial
Official title:
The Effect of Hydrodynamic Parameters on Corneal Endothelial Cell Loss After Phacoemulsification
The purpose of this study is to compare two surgical techniques (high vacuum and low vacuum) on corneal endothelium after phacoemulsification.
Patients aged 50 to 70 years old with moderate lens opacities (nuclear sclerosis of 3+) were
included. The exclusion criteria were: 1-previous corneal pathology (dystrophic or
degenerative such as Fuchs' endothelial dystrophy or advanced trachoma), 2-
pseudoexfoliation syndrome (PEX), 3- history of intra ocular surgery, 4- glaucoma or ocular
hypertension, 5- eyes with a history of anterior uveitis, 6- diabetes mellitus, 7- anterior
chamber depth (ACD) less than 2.5 mm or more than 4 mm, 8- axial length less than 21 mm or
more than 25 mm, 9- density of endothelial cells less than 1500 cells per mm2, 10-
polymegatism (CV > 0.4), 11- keratometric astigmatism more than 1.5 Diopters (D), 12-
history of contact lens usage, 13- Intra-operative complications (posterior capsule rupture
with or without vitreous loss), 14- postoperative uveitis, 15- postoperative surgical wound
leakage, 16- deep-set eye, and 17- size of dilated pupil less than 6 mm. Nucleus density was
evaluated using the LOCS III classification system Patients were divided in 2 groups
randomly: Group 1 included those candidates for phacoemulsification using high hydrodynamic
parameter: 400 mmHg vacuum and 40 ml/min flow rate (high vacuum technique) whereas group 2
consisted of patients who underwent phacoemulsification using low hydrodynamic parameters:
200 mmHg vacuum and 20 ml/min flow rate (low vacuum technique). All surgeries were performed
by one surgeon using stop and chop technique with sovereign (white star technology) (AMO,
USA). During sculpting stage, vacuum was 40mmHg and flow rate is 20ml/min, in both groups.
Irrigation aspiration of cortical material and viscoelastic were bimanually and semi
automatically performed with flow rate of 30ml/min.
Total ultrasound power and total volume of BSS in both groups were measured. Pachymetry,
endothelial cell density, polymegathism, before and 1, 6 and 12 weeks after intervention
were also evaluated. Statistically analysis of data included univariate (student t-test and
x2) and multivariate (regression model) analysis of postoperative results.
;
Allocation: Randomized, Endpoint Classification: Safety/Efficacy Study, Intervention Model: Parallel Assignment, Masking: Single Blind (Subject), Primary Purpose: Treatment
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT04685538 -
Chloroprocaine 3% Gel Eye Drop as Topical Anestheticsin Phacoemulsification.
|
Phase 3 | |
Recruiting |
NCT06060041 -
IC-8 Apthera IOL New Enrollment Post Approval Study
|
||
Recruiting |
NCT05518539 -
Evaluation of Quality of Vision and Visual Outcomes With Bilateral Implantation of the Clareon PanOptix Intraocular Lens
|
||
Recruiting |
NCT05271942 -
Tilt and Tumble vs Divide and Conquer - a Unique Comparison of the Two Cataract Surgery Methods
|
N/A | |
Active, not recruiting |
NCT04778501 -
PMCF Study on Monofocal Toric IOL (PODEYE TORIC) in Asia
|
N/A | |
Completed |
NCT05062564 -
Efficacy of LipiFlow in Patients Affected by Meibomian Gland Dysfunction in Reducing Post-cataract Surgery Dry Eye
|
N/A | |
Completed |
NCT03751033 -
Influence of DisCoVisc Ophthalmic Viscosurgical Device (OVD) on Intraoperative Aberrometry Readings
|
N/A | |
Completed |
NCT02529488 -
Investigation of AcrySof® IQ PanOptix™ Presbyopia-Correcting Intraocular Lens (IOL) Model TFNT00
|
N/A | |
Completed |
NCT04539548 -
A Study Assessing the Safety and Efficacy of Dextenza® for the Treatment of Ocular Pain and Inflammation Following Surgery for Pediatric Cataract
|
Phase 3 | |
Completed |
NCT03740659 -
Evaluation Of Aqueous Humor Of Levofloxacin-Dexamethasone Eye Drops And Of Its Components In Patients Undergoing Cataract Surgery
|
Phase 2 | |
Completed |
NCT03494257 -
Effect of Fixed Brinzolamide-brimonidine Combination on Intraocular Pressure After Phacoemulsification
|
N/A | |
Completed |
NCT05119127 -
Rotational Stability of Acrysof IQ Vivity Extended Vision Toric IOL and Refractive Visual Outcome.
|
N/A | |
Active, not recruiting |
NCT04271709 -
Manhattan Vision Screening and Follow-Up Study (NYC-SIGHT)
|
N/A | |
Recruiting |
NCT03713268 -
Intraoperative OCT Guidance of Intraocular Surgery II
|
||
Completed |
NCT03739528 -
Levo-Dexa vs. Tobra+Dexa for Prevention and Treatment of Inflammation and Prevention of Infection in Cataract Surgery
|
Phase 3 | |
Completed |
NCT02888210 -
A Study Assessing Safety and Efficacy of MD-15 Intraocular Lens in Patients With Aphakic Eye After Cataract Surgery
|
Phase 3 | |
Completed |
NCT03356847 -
Evaluation of the Rotational Stability of the Monofocal SISA Implant Following Cataract Surgery
|
N/A | |
Completed |
NCT04332640 -
Clinical Evaluation of the Next Generation Phaco System
|
N/A | |
Recruiting |
NCT03638726 -
Subconjunctival Atropine and Intracameral Epinephrine for Pupil Dilation in Phacoemulsification
|
Phase 4 | |
Completed |
NCT03050697 -
Evaluation of the Safety and Performance of the HARMONI® Toric Lens
|
N/A |