Amputation Clinical Trial
— EASEOfficial title:
EmPOWERing Active Seniors With Energy
NCT number | NCT02958553 |
Other study ID # | P16-01 |
Secondary ID | |
Status | Completed |
Phase | N/A |
First received | |
Last updated | |
Start date | February 10, 2017 |
Est. completion date | July 31, 2018 |
Verified date | April 2020 |
Source | Otto Bock Healthcare Products GmbH |
Contact | n/a |
Is FDA regulated | No |
Health authority | |
Study type | Interventional |
A pilot study comparing the emPOWER Ankle System to standard carbon fiber prosthetic feet, in active seniors.
Status | Completed |
Enrollment | 8 |
Est. completion date | July 31, 2018 |
Est. primary completion date | July 31, 2018 |
Accepts healthy volunteers | No |
Gender | All |
Age group | 55 Years and older |
Eligibility |
Inclusion Criteria: - Males and females - 55 years or older - Subjects with transtibial amputations of either leg at least 1 year prior - Suction or elevated vacuum suspension and Socket Comfort Score of at least 6 - Sock fluctuation of = 8 ply per day - K-level rating of 3 or 4 based on the Amputee Mobility Predictor Assessment Tool - Ability to walk at a walking speed of > 0.75 meters per second - Unilateral amputees (up to 7 bilateral amputees can be included, 1 per site in addition to the unilateral amputees who will be analyzed as a separate sub group) - Foot size: 25-30 cm - Ability to complete a continuous 6-Minute Walk Test - Ability to provide written, informed consent - Ability to complete study visits and study documents - Ability to manage the complexity of a powered device including charging and changing batteries as needed - Ability to read and understand English Exclusion Criteria: - Subjects who have never used a prosthetic device - Less than 55 years of age - Weight <150 lbs. or > 287 lbs. - Transfemoral amputees - Active sores or ulceration on subject's residual limb - Sore on contralateral foot. - Cuff-link socket suspension - Socket Comfort Score less than 6 - Sock fluctuation of > 8 per day - K level of 1 or 2 - Amputation clearance < 8.625" - History of stroke or TIA that impairs current walking - Recent history of excessive falling defined as more than 2 falls requiring medical assistance in the prior year - Medications potentially affecting balance - Recent hospitalization (within past 3 months) - Cognitive deficiency that would impact ability to charge and change batteries as needed |
Country | Name | City | State |
---|---|---|---|
United States | UTHealth, Department of Orthopedic Surgery | Houston | Texas |
Lead Sponsor | Collaborator |
---|---|
Otto Bock Healthcare Products GmbH | BionX Medical Technologies, Inc. |
United States,
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Other | Activity Diary | Self-Report Diary: Falls and daily activity. This was used to capture daily step counts from the Fitbit, daily activity and adverse events. It was a data collection tool, but was originally named as an Secondary Outcome. | 3 months | |
Primary | Number of Participants With Improvement, No Change, or Worsening in Performance in the Six Minute Walk Test (6MWT) | The proportion of patients with a clinically meaningful change (improvement, no change, worsening) in the walking distance measured by the Six Minute Walk Test (6MWT). 6minWT improvement was defined as a minimum increase of 45 meters. | 3 months with the emPOWER ankle | |
Secondary | Number of Participants With Improvement, No Change, or Worsening in Performance in the Twelve Minute Walk Test (12MWT) | The proportion of patients with a clinically meaningful change (improvement, no change, worsening) in the walking distance measured by the Twelve Minute Walk Test (12MWT). 12minWT improvement was defined as a minimum increase of 90 meters. | 3 months with the emPOWER ankle | |
Secondary | Number of Participants With Improvement, No Change, or Worsening in Performance in the 10 Meter Walk Test (10MWT) | The proportion of patients with a clinically meaningful change (improvement, no change, worsening) in the walking distance measured by the 10 Meter Walk Test (10MWT). 10MWT improvement was defined as a minimum increase of 0.1 m/s. | 3 months with the emPOWER ankle | |
Secondary | Number of Participants With Improvement, No Change, or Worsening in Performance in the L-Test | The proportion of patients with a clinically meaningful change (improvement, no change, worsening) in the walking time measured in the L-Test. L-Test improvement was defined as a minimum decrease of 4.5 seconds. | 3 months with the emPOWER ankle | |
Secondary | Number of Participants With Improvement, No Change, or Worsening in Performance in the Ramp Test | The proportion of patients with a clinically meaningful change (improvement, no change, worsening) in the walking time measured in theRamp Test. Ramp Test improvement was defined as a minimum decrease of 6 seconds to complete the test. | 3 months with the emPOWER ankle | |
Secondary | Number of Participants With Improvement, No Change, or Worsening in Performance in the Activities-specific Balance Confidence (ABC) Scale Score | The proportion of patients with a clinically meaningful change (improvement, no change, worsening) in abulatory activities measured by the Activities-specific Balance Confidence Scale. Improvement in the ABC was defined as a minimum detectable change of 13% increase in score. The ABC Scale is a self-administered questionnaire that asks the patient to rate his or her confidence in performing various ambulatory activities on a scale from 0% (no confidence) to 100% (complete confidence) without losing balance or becoming unsteady. Scores for each of the 16 items will be collected and an average percentage calculated, with scores <67 indicating an increased risk of falling. |
3 months with the emPOWER ankle | |
Secondary | Number of Participants With Improvement, No Change, or Worsening in Performance in the Falls Efficacy Scale Score | The Falls Efficacy Scale is a validated 10-item self-report questionnaire designed to assess confidence in the ability to perform 10 activities of daily living without falling as an indicator of how one's fear of falling impacts physical performance. Each item is rated from 1 ("very confident") to 10 ("not confident at all"), and the per item ratings are added to generate a summary total score (10 to 100). Lower scores indicate more confidence and higher scores indicate lack of confidence and greater fear of falling. It has been validated for use in the elderly and persons with amputations. Scores =70 indicate an increased fear of falling. Improvement in the Falls Efficiacy Scale was defined as a minimum increase of 2 in the score. | 3 months with the emPOWER ankle | |
Secondary | Number of Participants With Improvement, No Change, or Worsening in Performance in the Amputee Mobility Predictor (AMP) Assessment | The AMP is an instrument designed to measure ambulatory potential of lower-limb amputees. Subjects begin the test seated in a hard chair with arms and are tested for a total of 21 items assessing abilities of increasing level of difficulty. Abilities assessed include sitting balance, transfer from chair to chair, standing balance, gait quality, negotiating obstacles, and the use of assistive devices. The total score range for the AMP is 0 to 47 points. A minimal detectable change of 4 points was the definition of improvement. | 3 months with the emPOWER ankle | |
Secondary | Number of Participants With Improvement, No Change, or Worsening in Performance in the Prosthetic Limb Users Survey of Mobility PLUS-M (12 Item Short Form) | The PLUS-M is a valid and reliable self-reported measure for the mobility of adults with lower limb amputations. PLUS-M asks about the patient's ability to perform simple and complex tasks. High PLUS-M scores correspond with greater mobility. Improvement in the Mobility PLUS-M (12 item Short Form) was defined by a minimum detectable change of an increase of 5 points in the total score. | 3 months with the emPOWER ankle | |
Secondary | Number of Participants With Improvement, No Change, or Worsening in Performance in the Patient Specific Functional Scale (PSFS) | The PSFS is a self-report, goal-attainment measure aimed at identifying functional status limitations that are most relevant to individual patients. The PSFS is a reliable, valid, and efficient measure for detecting clinical change in persons with low back pain and knee dysfunction. Subjects were asked to identify three to five activities that they are having difficulty or are unable to perform because of their injury/condition. For the specified activities, patients were asked to rate their ability to perform each activity at that time (0-10 numerical scale) with '0' being unable to perform the activity, and '10' being able to perform the activity at the same level as they could prior to the injury/condition. The total score was calculated as the sum of the activity scores divided by the number of activities. Changes of >2 in the total score compared to baseline were considered "Improved." | 3 months with the emPOWER ankle | |
Secondary | Number of Participants With Improvement, No Change, or Worsening in Performance in the Numeric Pain Rating Scale (NPRS) | The NPRS is a valid and reliable measure of pain that may be used across all musculoskeletal injuries/conditions and complements the PSFS. The patient was asked to rate the pain of their joints, foot, lower back, and if they are using an assistive device any additional affected limbs on average over the last 24 hours on a scale 1-10, with '1' being 'very mild' and '10' being the 'unimaginable unspeakable'. The scores on the NPRS instruments with the emPOWER Ankle were compared to the scores on the subject's passive prosthesis. An improvement was considered a positive change of 1 for at least one area without a corresponding decrease in another. | 3 months with the emPOWER ankle | |
Secondary | Number of Participants With Improvement, No Change, or Worsening in Performance in Activity (Monitoring Using a Fitbit Over 2-week Periods) | A Fitbit activity monitor was worn to record the number of steps the Subject took with the prosthesis. The patient returned to the site with the activity monitor and the steps counted were downloaded from the device. In addition, the Subjects were sent home with a prepaid envelope and instructed to mail back the activity monitor if the next visit was more than 3 weeks later, to ensure that the data was not lost. The step counts were downloaded from the device the day the activity monitor was returned to the Investigator. The Investigator recorded the date the patient was affixed with the activity monitor, the date they received the returned activity monitor, and the date they synced the monitor. An improvement was defined as an increase in the average daily step count of 750 steps. | 3 months with the emPOWER ankle | |
Secondary | Number of Participants With Improvement, No Change, or Worsening in Performance in PROMIS Physical Function | PROMIS item banks and their short forms are a reliable and precise measurements of patient reported outcome measures. The scores on the PROMIS instruments with the emPOWER Ankle 3 months after fitting will be compared to the scores on the subject's passive prosthesis. PROMIS Physical Function improvement was defined as a minimally clinically important difference (MCID) of an increase of 6.8 in a total score. | 3 months with the emPOWER ankle | |
Secondary | Number of Participants With Improvement, No Change, or Worsening in Performance in PROMIS Global Health Short Form | PROMIS item banks and their short forms are a reliable and precise measurements of patient reported outcome measures. The scores on the PROMIS instruments with the emPOWER Ankle 3 months after fitting will be compared to the scores on the subject's passive prosthesis. PROMIS Global Health Short Form improvement was defined as an increase in a total score of 3.5. | 3 months with the emPOWER ankle | |
Secondary | Number of Participants With Improvement, No Change, or Worsening in Performance in PROMIS Fatigue Short Form (7a) | PROMIS item banks and their short forms are a reliable and precise measurements of patient reported outcome measures. The scores on the PROMIS instruments with the emPOWER Ankle 3 months after fitting will be compared to the scores on the subject's passive prosthesis. PROMIS Fatigue Short Form (7a) improvement was defined as a minimally clinically important difference (MCID) of an increase of 5 in a total score. | 3 months with the emPOWER ankle | |
Secondary | Number of Participants With Improvement, No Change, or Worsening in Performance in PROMIS Pain Intensity Short Form (3a) | PROMIS item banks and their short forms are a reliable and precise measurements of patient reported outcome measures. The scores on the PROMIS instruments with the emPOWER Ankle 3 months after fitting will be compared to the scores on the subject's passive prosthesis. PROMIS Pain Intensity Short Form (3a) improvement was defined as a minimally clinically important difference (MCID) of an increase of 6.9 in a total score. | 3 months with the emPOWER ankle |
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT03947450 -
Autologous Volar Fibroblast Injection Into the Stump Site of Amputees
|
Phase 2 | |
Completed |
NCT04924036 -
Qbrexza Cloths for Hyperhidrosis of Amputation Sites
|
Phase 2 | |
Recruiting |
NCT04839497 -
Multicenter Trial Evaluating the Safety and Efficacy of Autologous Volar Fibroblast Injection Into the Terminal Limb of Amputees.
|
Phase 2 | |
Recruiting |
NCT04212299 -
Transfemoral Socket Design and Muscle Function
|
N/A | |
Completed |
NCT03733054 -
Understanding Prosthetic Needs and Outcomes in Women Veterans With Amputation
|
||
Completed |
NCT03651830 -
A Test-Drive Strategy for the Prescription of Prosthetic Feet for People With Leg Amputations
|
N/A | |
Recruiting |
NCT04725006 -
Sensory Responses to Dorsal Root Stimulation
|
N/A | |
Not yet recruiting |
NCT06007885 -
Examining Capacity Building of Youth With Physical Disabilities to Pursue Participation Following the PREP Intervention.
|
N/A | |
Not yet recruiting |
NCT04936789 -
Clinical Feasibility of the IMES Transradial Prosthesis
|
N/A | |
Completed |
NCT01155024 -
Clinical Evaluation of Direct Manufactured Prosthetic Sockets
|
Phase 2 | |
Completed |
NCT00663663 -
Telephone Intervention for Pain Study (TIPS)
|
N/A | |
Terminated |
NCT00778856 -
Hand Transplantation for the Reconstruction of Below the Elbow Amputations
|
N/A | |
Recruiting |
NCT00388752 -
Acupuncture for the Treatment of Phantom Limb and Residual Limb Pain After Amputation
|
Phase 1 | |
Active, not recruiting |
NCT03374319 -
Somatotopic Configuration of Distal Residual Limb Tissues in Lower Extremity Amputations
|
N/A | |
Completed |
NCT05542901 -
Comparison of Joint Position Sense in Diabetic and Traumatic Transtibial Amputees
|
N/A | |
Completed |
NCT05161364 -
Kinetic Analysis Due to Foot Dysfunction
|
||
Recruiting |
NCT06194838 -
Clinical Outcomes With Non-Powered vs. Powered Prosthetic Knees by K2-level Amputees
|
N/A | |
Completed |
NCT03570788 -
HRQoL Among Patients Amputated Due to Peripheral Arterial Disease
|
||
Completed |
NCT05778799 -
Physical Activity and Sports for People With Special Needs
|
||
Recruiting |
NCT04804150 -
Daily Socket Comfort in Transtibial Amputee With an Active Vacuum Suspension System
|
N/A |