Clinical Trials Logo

Clinical Trial Summary

This study will test the hypothesis that implantation of a subcutaneous implantable cardioverter defibrillator (S-ICD) without performing a defibrillation test is non-inferior to S-ICD implant with a defibrillation test with regards to the primary endpoint failed first shock in a spontaneous arrhythmia episode when implant position is confirmed with PRAETORIAN score.


Clinical Trial Description

Implantable Cardioverter Defibrillator (ICD) implant improves survival in patients with a higher risk for sudden cardiac death. There are 2 types of ICD available; transvenous ICD (TV-ICD) and subcutaneous ICD (S-ICD). During ICD implant, defibrillation testing (DFT) is performed to test functionality of the device. However, DFT can be associated with complications such as inability to convert, complications arising from general anaesthesia, prolonged resuscitation, stroke and death. Whereas DFT may be associated with complications, the benefit of DFT is debated as literature shows there is only a modest average effect of DFT, if any, on mortality, shock efficacy or safety. Recently it was shown in a randomized controlled trial called 'SIMPLE' that routine defibrillation testing of TV-ICDs at the time of implant does not improve shock efficacy or reduce arrhythmic death. For S-ICD there is only limited data available of the effect of DFT on S-ICD efficacy. Data have however shown that the conversion efficacy of the S-ICD is comparable to TV-ICD. DFT is currently performed in standard S-ICD implants, but is omitted in specific cases. However, an alternative method to evaluate the correct position may be desired when omitting DFT. The PRAETORIAN Score is developed using computer modelling data on factors influencing defibrillation thresholds. The PRAETORIAN score represents the chance of a patient having an elevated defibrillation threshold and consequently failing a DFT or conversion of a spontaneous arrhythmia episode. The score was retrospectively validated in two studies with 180 and 321 patients. It was reported that most S-ICD implants are performed under general anesthesia, however other anesthesia protocols are used as well. One of the most predominant factors to use general anesthesia is the performance of the DFT. If this is omitted, other anesthesia protocols may be a good option for many patients as well. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT03495297
Study type Interventional
Source Academisch Medisch Centrum - Universiteit van Amsterdam (AMC-UvA)
Contact
Status Active, not recruiting
Phase N/A
Start date May 7, 2018
Completion date October 2024

See also
  Status Clinical Trial Phase
Completed NCT05791032 - Sub Chronic Evaluation for ATP With an Extravascular Placed ICD Lead (STEP ICD) Study N/A
Not yet recruiting NCT06063811 - Ventricular Tachycardia Ablation in LVAD Patients
Withdrawn NCT05049720 - ExtraVascular Implantable Cardiac Defibrillator Continued Access Study N/A
Completed NCT04060680 - Extravascular ICD Pivotal Study N/A
Not yet recruiting NCT04990089 - VIVO European Observational Registry
Recruiting NCT05418036 - Safety Assessment for Sotalol Protocol in Outpatient Unit Phase 4
Recruiting NCT04264455 - Evaluation of Long-term Incidence of Ventricular Arrhythmias in Patients With Acute Myocarditis
Recruiting NCT03821051 - China Structural Ventricular Arrhythmias Registry
Recruiting NCT03880708 - China Inherited Ventricular Arrhythmias Registry
Recruiting NCT03041519 - Zero-fluoroscopic Ablation Versus Conventional Fluoroscopic Ablation for the Treatment of Ventricular Arrhythmias N/A
Completed NCT03204981 - Intramural Needle Ablation for the Treatment of Refractory Ventricular Arrhythmias N/A
Recruiting NCT04239144 - Sympathetic Denervation by Video-assisted Thoracoscopy in Control of Cardiac Arrhythmias in Patients With Chagas Disease N/A
Recruiting NCT05829993 - Development of an Artificial Intelligence Algorithm to Detect Pathological Repolarization Disorders on the ECG and the Risk of Ventricular Arrhythmias
Recruiting NCT05707637 - Bipolar Radio-frequency Ablation After Standard Unipolar Approach - Prospective Registry.
Completed NCT05357716 - Preliminary Research Evaluation for Ambulatory Leadless Electrocardiogram Recorder Trial
Recruiting NCT06158698 - CMP-MYTHiC Trial and Registry - CardioMyoPathy With MYocarditis THerapy With Colchicine Phase 3
Suspended NCT03502499 - Half-normal Saline in Idiopathic Left Ventricular Outflow Tract Arrhythmias Ablation N/A
Completed NCT04809701 - Non-vascular ICD Electrode Configuration Feasibility Study N/A
Withdrawn NCT03258112 - Safety and Efficacy of Catheter Ablation of Idiopathic Ventricular Arrhythmias Arising From Cardiac Outflow Tracts N/A
Completed NCT02099721 - Improve Sudden Cardiac Arrest Study N/A