Clinical Trials Logo

Clinical Trial Summary

With this project the investigators wish to:

1. Test the reproducibility of Amlang's ultrasound classification by examining the intra- and inter-rater reliability.

2. Investigate whether Amlang's ultrasound classification is able to predict which patients are likely to develop complications when treated non-operatively.

3. Investigate whether Barfod's length measurement is able to predict which patients are likely to develop complications when treated non-operatively.


Clinical Trial Description

Study objectives

To validate Amlang's ultrasound classification and investigate whether the treatment of acute Achilles tendon ruptures (ATR) can be guided by:

1. Amlang's ultrasound classification of ATR

2. Barfod's ultrasound measurement to determine the elongation of the Achilles tendon following a rupture Backgrund A larger group of patients end up with a poor outcome after treatment for ATR. ATR is a frequent and potentially debilitating injury that typically affects young active adults (11 to 37 per 100,000)1 2 3. Consequently, there are great socioeconomic benefits in optimizing treatment and shortening time of recovery.

There is currently no consensus regarding the best treatment of ATR. Traditionally the operative treatment has been considered superior, however recent studies show that non-operative treatment is a safe treatment which leads to good results 4 5 6. For this reason a transition towards greater use of non-operative treatment is seen in many orthopedic departments 7.

Patients who end up with a poor result after treatment for ATR typically suffer from rerupture of the tendon or an elongation of the tendon. There is a 5-10 percent risk of rerupture 4 5 6. It is unknown how many patients heal with an elongation of the Achilles tendon. Correct length of the Achilles tendon is essential for the subsequent function of the tendon.

In order to shorten time of recovery and optimize the treatment-outcome, it is desirable to identify patients at risk of re-rupture or elongation as early as possible as early surgery might help these patients.

Amlang et al. have developed an ultrasonographic classification system to be used in the acute phase of rupture 8. The aim is to predict whether the patient will benefit from operative or non-operative treatment. The classification system appears well considered; however, the classification needs validation and to be correlated to outcome.

Barfod et al. have developed a method for measuring the prolongation of the Achilles tendon in the acute phase following a rupture. The length measurement has been validated using healthy subjects. Data are analyzed and publication is expected autumn 2013. It has not been tested whether the measurement works on torn Achilles tendons and whether there is a correlation between the measurement and outcome.

With this project the investigators wish to:

1. Teste the reproducibility of Amlang's ultrasound classification by examining the intra- and inter-rater reliability.

2. Investigate whether Amlang's ultrasound classification is able to predict which patients are likely to develop complications when treated non-operatively.

3. Investigate whether Barfod's length measurement is able to predict which patients are likely to develop complications when treated non-operatively.

Study Design Type of study The study is carried out as a prospective cohort study. Time schedule The recruitment of patients will begin 1 of November 2013. It is expected that the study will be completed after 4-5 years; the recruitment itself is expected to span 2 years, provided that an average of 6 patients is included per month.

Discontinuation Each patient can choose to withdraw from the trial at any time. A patient may also be withdrawn from the trial at any time based on the investigators' discretion.

Method Amlang's ultrasound classification and Barfod's length measurement are determined as described below. For the initial 30 patients Amlang's ultrasound classification will be determined using two independent ultrasound-operators in order to test the inter-observer consistency.

Ultrasound - Set up The patient is in the prone position with the knees slightly flexed (10 -20 degrees). A triangular foam pad is placed below (anterior to) the ankle joints, so that the feet are resting limply. By moving the pad up (cranial) and down (caudal) the angle of the relaxed ankle joints is adjusted to 20 degrees plantar flexion. The angle is measured using a goniometer (the longitudinal axis of the fibula is at 110 degrees with the posterior part of the lateral border of the foot). The calf muscles are relaxed.

Amlang's ultrasound classification Amlang's ultrasound classification is conducted by determining the cross-sectional area of the widest point of the tendon below (distal to) the rupture (area-widest) and of the narrowest point at the rupture site (area-smallest). The ratio between "area-smallest" and "area-widest" is interpreted as a measure for the magnitude of overlap between the tendon ends. A ratio above 70 percent is considered as a total adaption of the tendon ends. A ratio of 30 to 70 percent is considered as a partial adaption of the tendon ends. And a ratio of less than 30 percent is considered as a lack of adaption of the tendon ends.

Barfod's length measurement Barfod's length measurement is conducted using a simple method that does not require expensive equipment or advanced instruments. A needle is placed between the skin and the ultrasonographic probe. The shadow of the needle then projects the internal structures to the skin surface and the distance between calcaneus and the medial head of the gastrocnemius muscle can then be measured.

Study Design Type of study The study is carried out as a prospective cohort study. Time schedule The recruitment of patients will begin 1 of November 2013. It is expected that the study will be completed after 4-5 years; the recruitment itself is expected to span 2 years, provided that an average of 6 patients is included per month.

Discontinuation Each patient can choose to withdraw from the trial at any time. A patient may also be withdrawn from the trial at any time based on the investigators' discretion.

Method Amlang's ultrasound classification and Barfod's length measurement are determined as described below. For the initial 30 patients Amlang's ultrasound classification will be determined using two independent ultrasound-operators in order to test the inter-observer consistency.

Ultrasound - Set up The patient is in the prone position with the knees slightly flexed (10 -20 degrees). A triangular foam pad is placed below (anterior to) the ankle joints, so that the feet are resting limply. By moving the pad up (cranial) and down (caudal) the angle of the relaxed ankle joints is adjusted to 20 degrees plantar flexion. The angle is measured using a goniometer (the longitudinal axis of the fibula is at 110 degrees with the posterior part of the lateral border of the foot). The calf muscles are relaxed.

Amlang's ultrasound classification Amlang's ultrasound classification is conducted by determining the cross-sectional area of the widest point of the tendon below (distal to) the rupture (area-widest) and of the narrowest point at the rupture site (area-smallest). The ratio between "area-smallest" and "area-widest" is interpreted as a measure for the magnitude of overlap between the tendon ends. A ratio above 70 percent is considered as a total adaption of the tendon ends. A ratio of 30 to 70 percent is considered as a partial adaption of the tendon ends. And a ratio of less than 30 percent is considered as a lack of adaption of the tendon ends.

Barfod's length measurement Barfod's length measurement is conducted using a simple method that does not require expensive equipment or advanced instruments. A needle is placed between the skin and the ultrasonographic probe. The shadow of the needle then projects the internal structures to the skin surface and the distance between calcaneus and the medial head of the gastrocnemius muscle can then be measured.

Statistics The groups will be described descriptively regarding demographic parameters as well as primary and secondary endpoints. The correlation between Amlang's ultrasound classification and the primary and secondary endpoints will be examined using a regression analysis. The correlation between Barfod's length measurement and the primary and secondary endpoints will be examined in the same way.

The research group The study is carried out as collaboration between the research unit, Clinical Orthopaedic Research Hvidovre (www.corh.dk) and the Department of Physical- and Occupational Therapy, both at Copenhagen University Hospital Hvidovre. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT02062567
Study type Observational
Source Hvidovre University Hospital
Contact
Status Completed
Phase N/A
Start date February 2014
Completion date January 2018

See also
  Status Clinical Trial Phase
Completed NCT04546867 - Establishing a Sonographic Based Algorithm to Verify Pancreatic Stent Position Placed to Prevent Post-ERCP Pancreatitis Before Endoscopic Removal N/A
Not yet recruiting NCT06053892 - AR US Versus sUS or Fluoroscopic Injections for Shoulder Punction N/A
Completed NCT05013476 - Tele-Ultrasound: VIrtual Hands-on Education for Novice Users N/A
Completed NCT04554472 - Usefulness of Intraoperative Ultrasound in a Volar Plate Distal Radius Fixation
Not yet recruiting NCT04550793 - Using Shear Wave Ultrasound Elastography for Follow up After Anti-spastic Intervention Among Stroke Patients
Completed NCT03563196 - Diagnosis Of Pulmonary Complications After Cardiac Surgery In Children
Completed NCT01666626 - Ultrasound Stiffness Imaging in Crohn's Disease N/A
Active, not recruiting NCT04928560 - Diagnosis of Superficial Lymphadenopathy
Recruiting NCT05938790 - Point of Care Ultrasound in Obstetric Triage N/A
Recruiting NCT06098105 - Laparoscopic vs Ultrasound-Guided Transversus Abdominis Plane Block vs Laparoscopic Intraperitoneal Instillation of Local Anesthetic in Pediatrics N/A
Recruiting NCT02834585 - Magnetic Resonance Imaging or Ultrasound in Soft Tissue Tumors (MUSTT) N/A
Completed NCT02661607 - Point of Care Echocardiography Versus Chest Radiography for the Assessment of Central Venous Catheter Placement N/A
Completed NCT01519167 - Open-Label, Safety Study Evaluating the Use of Dexmedetomidine in Pediatric Subjects Undergoing Procedure-Type Sedation Phase 4
Completed NCT04612816 - Live Stream of Ultrasound in Prehospital Medical Care
Active, not recruiting NCT06195488 - Gastric Ultrasound in Diabetic Patients
Recruiting NCT06199856 - Assessment System for Sarcopenia Based on Ultrasonographic Data
Not yet recruiting NCT04563897 - Prospective Multicenter Study on Clinical Application of Sonazoid in Liver Tumor
Completed NCT04574258 - Prospective Multicenter Study on Clinical Application of Sonozoid in Thyroid Tumor
Completed NCT04124770 - Neck Position and Ultrasound Landmark of Cricothyroid Membrane
Completed NCT04229654 - Awareness, Expectations, and Perception of Anomaly Scan Among Mexican Pregnant Women