This study is divided into 5 arms:

1. Randomized Clinical Trial (RCT): Prospective, randomized, active-controlled, single blind, parallel two-arm multi-center clinical trial in the United States (US) comparing XIENCE V® Everolimus Eluting Coronary Stent System (CSS) (2.5, 3.0, 3.5 mm diameter stents) to the Food and Drug Administration (FDA) approved commercially available active control TAXUS® EXPRESS2™ Paclitaxel Eluting Coronary Stent (TAXUS® EXPRESS2™ PECS) System

2. US 2.25 mm non-randomized arm using 2.25 mm diameter XIENCE V® Everolimus Eluting CSS

3. US 4.0 mm non-randomized arm using 4.0 mm diameter XIENCE V® Everolimus Eluting CSS

4. US 38 mm non-randomized arm using 38 mm in length XIENCE V® Everolimus Eluting CSS

5. Japanese non-randomized arm using XIENCE V® Everolimus Eluting CSS (2.5, 3.0, 3.5, 4.0 mm diameter stents) in Japan

The TAXUS® EXPRESS2™ Paclitaxel Eluting Coronary Stent System is Manufactured by Boston Scientific.


Clinical Trial Description

The purpose of the SPIRIT III clinical trial is to evaluate the safety and efficacy of the XIENCE V® Everolimus Eluting Coronary Stent System (XIENCE V® EECSS). The XIENCE V® EECS (XIENCE V® arm) will be compared to an active control group represented by the FDA approved commercially available Boston Scientific TAXUS® EXPRESS2™ Paclitaxel-Eluting Coronary Stent (TAXUS® EXPRESS2™ PECS) System (TAXUS® arm).

The SPIRIT III clinical trial consists of a randomized clinical trial (RCT) in the US which will enroll approximately 1,002 subjects (2:1 randomization XIENCE V® EECS : TAXUS® EXPRESS2™ PECS) with a maximum of two de novo native coronary artery lesion treatment within vessel sizes >= 2.5 mm and <= 3.75 mm.

The SPIRIT III clinical trial also consists of three concurrent US non-randomized arms (2.25 mm diameter stent, 4.0 mm diameter stent and 38 mm length stent arms) and one Japanese non-randomized arm as follows:

1. 105 subjects with a maximum of two de novo native coronary artery lesion within vessel sizes > 2.25 mm and < 2.5 mm and lesion length <= 22 mm will be enrolled concurrently in the US 2.25 mm non-randomized treatment arm

2. 80 subjects with a maximum of two de novo native coronary artery lesion within vessel sizes > 3.75 mm and >= 4.25 mm and lesion length <= 28 mm will be enrolled concurrently in the US 4.0 mm non-randomized treatment arm

3. 105 subjects with a maximum of two de novo native coronary artery lesion within vessel sizes > 3.0 mm and < 4.25 mm and lesion length > 24 mm and < 32 mm will be enrolled concurrently in the US 38 mm non-randomized treatment arm.

4. 88 Japanese subjects with a maximum of two de novo native coronary artery lesions within vessel sizes >= 2.5 mm and <= 4.25 mm and lesion length <= 28 mm will be enrolled concurrently in the non-randomized Japanese arm.

All subjects in the RCT and the four non-randomized arms will be screened per the protocol required inclusion/exclusion criteria. The data collected will be compared to data from the subjects enrolled into the TAXUS® arm of US RCT.

Subjects enrolled in the US RCT will be sub-grouped based on whether they will have an angiographic and/or an intravascular ultrasound (IVUS) follow-up at 240 days as follows:

Group A: Angiographic and IVUS follow-up at 240 days (N=240) Group B: Angiographic follow-up at 240 days (N=324) Group C: No angiographic or IVUS follow-up (N=438)

All subjects will have clinical follow-up at 30, 180, 240 and 270 days (Data collected through 270 days will be submitted as the primary data set for US and Japanese market approval), and 1, 2, 3, 4, and 5 years (for annual reports).

All subjects enrolled into three US non-randomized arms (N=105 for 2.25 mm arm, N=80 for 4.0 mm arm and N=105 for 38 mm stent arm) will have clinical follow-up at 30, 180, 240, and 270 days, and angiographic follow-up at 240 days. No IVUS follow-up is required for subjects enrolled in these arms.

All subjects enrolled into the Japanese non-randomized arm (N=88) will have clinical follow-up at 30, 180, 240, and 270 days, and angiographic and IVUS follow-up at 240 days.

All subjects who receive a bailout stent will be assigned to Group A follow-up subgroup (angiographic and IVUS follow-up at 240 days after the index procedure), regardless of their primary assignment at randomization. At sites without IVUS capability, subjects receiving bailout stent will be assigned to Group B follow-up subgroup (angiographic follow-up at 240 days after the index procedure). Angiographic follow-up is required for all bailout subjects at 240 days.

Data from the US RCT will be submitted to the FDA as the primary data set for product approval for RVD >= 2.5 mm and <= 3.75 mm (2.5 mm, 3.0 mm and 3.5 mm stents). Combined data of the US trial/Japanese non-randomized arm will be submitted to the Japanese Ministry of Health, Labor and Welfare (MHLW) for Japanese approval for RVD>=2.5 mm and <= 4.25 mm (2.5 mm, 3.0 mm 3.5 mm and 4.0 mm stents). Data from the Japanese non-randomized arm will be submitted to the FDA as additional safety data. Data from the US non-randomized arms of the trial will be the primary data sets for approval for 2.25 mm diameter stent (RVD > 2.25 mm and < 2.5 mm), 4.0 mm diameter stent (RVD > 3.75 mm and <= 4.25 mm) and 38 mm length stent (RVD > 3.0 mm and <= 4.25 mm and lesion length > 24 mm and <= 32 mm), respectively in the US.

A pharmacokinetic substudy will be carried out in a minimum of 5 pre-determined sites in the US and a minimum of 5 pre-determined sites in Japan. In the US, the pharmacokinetics (PK) of everolimus, as delivered by the XIENCE V® EECS will be analyzed in a subset of 15 subjects (minimum) with single vessel/lesion treatment, and up to 20 subjects with dual vessel/lesion treatment, respectively. In Japan, a minimum of 10 subjects with single vessel/lesion treatment and up to 20 subjects with dual vessel/lesion treatment will have a PK measurements performed. These subsets will include subjects receiving overlapping stents. ;


Study Design

Allocation: Randomized, Endpoint Classification: Safety/Efficacy Study, Intervention Model: Parallel Assignment, Masking: Single Blind (Subject), Primary Purpose: Treatment


Related Conditions & MeSH terms


NCT number NCT00180479
Study type Interventional
Source Abbott Vascular
Contact
Status Completed
Phase Phase 3
Start date June 2005
Completion date November 2011

See also
  Status Clinical Trial Phase
Recruiting NCT06030596 - SPECT Myocardial Blood Flow Quantification for Diagnosis of Ischemic Heart Disease Determined by Fraction Flow Reserve
Completed NCT04080700 - Korean Prospective Registry for Evaluating the Safety and Efficacy of Distal Radial Approach (KODRA)
Recruiting NCT03810599 - Patient-reported Outcomes in the Bergen Early Cardiac Rehabilitation Study N/A
Recruiting NCT06002932 - Comparison of PROVISIONal 1-stent Strategy With DEB Versus Planned 2-stent Strategy in Coronary Bifurcation Lesions. N/A
Not yet recruiting NCT06032572 - Evaluation of the Safety and Effectiveness of the VRS100 System in PCI (ESSENCE) N/A
Recruiting NCT05308719 - Nasal Oxygen Therapy After Cardiac Surgery N/A
Recruiting NCT04242134 - Drug-coating Balloon Angioplasties for True Coronary Bifurcation Lesions N/A
Completed NCT04556994 - Phase 1 Cardiac Rehabilitation With and Without Lower Limb Paddling Effects in Post CABG Patients. N/A
Recruiting NCT05846893 - Drug-Coated Balloon vs. Drug-Eluting Stent for Clinical Outcomes in Patients With Large Coronary Artery Disease N/A
Recruiting NCT06027788 - CTSN Embolic Protection Trial N/A
Recruiting NCT05023629 - STunning After Balloon Occlusion N/A
Completed NCT04941560 - Assessing the Association Between Multi-dimension Facial Characteristics and Coronary Artery Diseases
Completed NCT04006288 - Switching From DAPT to Dual Pathway Inhibition With Low-dose Rivaroxaban in Adjunct to Aspirin in Patients With Coronary Artery Disease Phase 4
Completed NCT01860274 - Meshed Vein Graft Patency Trial - VEST N/A
Recruiting NCT06174090 - The Effect of Video Education on Pain, Anxiety and Knowledge Levels of Coronary Bypass Graft Surgery Patients N/A
Terminated NCT03959072 - Cardiac Cath Lab Staff Radiation Exposure
Completed NCT03968809 - Role of Cardioflux in Predicting Coronary Artery Disease (CAD) Outcomes
Recruiting NCT04566497 - Assessment of Adverse Outcome in Asymptomatic Patients With Prior Coronary Revascularization Who Have a Systematic Stress Testing Strategy Or a Non-testing Strategy During Long-term Follow-up. N/A
Recruiting NCT05065073 - Iso-Osmolar vs. Low-Osmolar Contrast Agents for Optical Coherence Tomography Phase 4
Completed NCT05096442 - Compare the Safety and Efficacy of Genoss® DCB and SeQuent® Please NEO in Coronary De Novo Lesions N/A