Clinical Trials Logo

Clinical Trial Summary

The investigators believe that ultrasound guided CSE technique will accurately place the epidural needle in the midline position compared to epidural needle placement via palpation of anatomical landmarks. This will result in positive CSF in the spinal needle, correct placement of the catheter, and adequate symmetrical labor analgesia/anesthesia.


Clinical Trial Description

Epidurals provide superior labor analgesia and anesthesia. Unfortunately, failure of epidural anesthesia and analgesia is a frequent clinical problem. In a heterogeneous cohort of 2,140 surgical patients, a failure rate of 27% for lumbar epidural was described. However, the definition of a failed epidural is broad. Different definitions include insufficient analgesia to catheter dislodgement to conversion to general anesthesia. Epidural analgesia failures may result from technical difficulties, insufficiencies or overdosing of local anesthetics, epidural septum or midline adhesions, and placement of the epidural catheter through an intervertebral foramen or into the anterior epidural space. In an imaging study of failed epidurals, incorrect catheter placement accounted for half of the failures, while the remaining patients experienced suboptimal analgesia through a correctly positioned catheter.

The incidence of overall failure was lower in patients receiving combined spinal-epidural (CSE) catheters versus epidural analgesia. In one study, the CSE technique provided decreased failure rates for labor analgesia and comparable or decreased failure rates for surgical anesthesia, when compared with reported failure rates for epidural anesthesia. It is believed that positive CSF flow in the spinal needle confirms correct epidural needle placement in the epidural space and also confirms the epidural needle to be in the midline position. Placement of the epidural needle in the midline position will minimize the incorrect placement of the catheter to one side, providing a symmetrical analgesia versus unilateral analgesia.

However, the practice of CSE and epidural catheter placement relies on the palpation of anatomical landmarks that are not always easy to feel. Therefore, the epidural needle maybe placed "off midline" despite positive loss of resistance (LOR) that causes negative CSF flow in the spinal needle and an incorrectly placed catheter. As a result, the incorrect catheter placement will result in a "failed" or suboptimal epidural analgesia.

Ultrasound has recently been utilized to facilitate lumbar epidurals and spinals. The US imaging of the lumbar spine in different scanning planes facilitates the identification of the landmarks necessary for appropriate epidural space location in pregnant patients. There are two acoustic windows that are effective for lumbar spine sonographic assessment: one seen on the transverse approach, and the other seen on the longitudinal paramedian approach. The ultrasound single-screen method using the transverse approach of the lumbar spine provides reliable information regarding the landmarks required for labor epidurals. The correct interspace and midline position are identified for correct placement of the CSE analgesia. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT02207972
Study type Interventional
Source St. Luke's-Roosevelt Hospital Center
Contact
Status Completed
Phase N/A
Start date May 2013
Completion date February 2015

See also
  Status Clinical Trial Phase
Completed NCT03442582 - Afluria Pregnancy Registry
Terminated NCT02161861 - Improvement of IVF Fertilization Rates, by the Cyclic Tripeptide FEE - Prospective Randomized Study N/A
Not yet recruiting NCT05934318 - L-ArGinine to pRevent advErse prEgnancy Outcomes (AGREE) N/A
Enrolling by invitation NCT05415371 - Persistent Poverty Counties Pregnant Women With Medicaid N/A
Completed NCT04548102 - Effects of Fetal Movement Counting on Maternal and Fetal Outcome Among High Risk Pregnant Woman N/A
Completed NCT03218956 - Protein Requirement During Lactation N/A
Completed NCT02191605 - Computer-delivered Screening & Brief Intervention for Marijuana Use in Pregnancy N/A
Completed NCT02223637 - Meningococcal Quadrivalent CRM-197 Conjugate Vaccine Pregnancy Registry
Recruiting NCT06049953 - Maternal And Infant Antipsychotic Study
Active, not recruiting NCT02577536 - PregSource: Crowdsourcing to Understand Pregnancy
Not yet recruiting NCT06336434 - CREATE - Cabotegravir & Rilpivirine Antiretroviral Therapy in Pregnancy Phase 1/Phase 2
Not yet recruiting NCT04786587 - Alcohol Self-reporting During Pregnancy. AUTOQUEST Study.
Not yet recruiting NCT05412238 - Formulation and Evaluation of the Efficacy of Macro- and Micronutrient Sachets on Pregnant Mothers and Children Aged 6-60 Months N/A
Not yet recruiting NCT05028387 - Telemedicine Medical Abortion Service Using the "No-test" Protocol in Ukraine and Uzbekistan.
Completed NCT02783170 - Safety and Immunogenicity of Simultaneous Tdap and IIV in Pregnant Women Phase 4
Completed NCT02683005 - Study of Hepatitis C Treatment During Pregnancy Phase 1
Recruiting NCT02619188 - Nutritional Markers in Normal and Hyperemesis Pregnancies N/A
Recruiting NCT02507180 - Safely Ruling Out Deep Vein Thrombosis in Pregnancy With the LEFt Clinical Decision Rule and D-Dimer
Recruiting NCT02564250 - Maternal Metabolism and Pregnancy Outcomes in Obese Pregnant Women N/A
Completed NCT02379728 - Ghana PrenaBelt Trial: A Positional Therapy Device to Reduce Still-Birth N/A