Clinical Trials Logo

Clinical Trial Summary

The study is intended to evaluate the safety and feasibility of using the Intact Vascular (Innovasc) Tack-It Endovascular Dissection Repair System (Tack Intravascular Staple System) in patients with vascular flaps in the infrainguinal due post-angioplasty dissection.


Clinical Trial Description

The primary objective of the study is to evaluate the safety of delivery and placement of the Innovasc Tack Intravascular Staple System on vascular flaps in the SFA, created by percutaneous transluminal balloon angioplasty Safety will be evaluated as the 30-day (or hospital discharge date, whichever is longer) rate of major adverse events defined as the composite endpoint of death, device embolization, the occurrence of surgery related to the device, device related occlusion of the artery, or major unplanned amputation of the ipsilateral lower extremity. The secondary objective is to evaluate the feasibility of using the Innovasc Tack Intravascular Staple System to permanently secure vascular flaps. Secondary Evaluation of Feasibility (technical success) of the Innovasc Tack Intravascular Staple System (procedure and device) will be evaluated acutely by the following: - Feasibility is defined as the ability to accurately place the Plaque Tacks and resolve post-PTA dissection flaps prior to the conclusion of the procedure, as demonstrated by angiography - Acute technical success: Acute luminal patency during the revascularization procedure using standard angiography which demonstrates that the lumen of the artery at the location of tack implant remains patent at the conclusion of the procedure. The additional objectives of the study are to assess additional parameters as follows: - Long term success will be assessed at one (1) month and three (3) months by evaluation of post-implant stability of the Plaque Tack relative to vascular or external landmarks at 30 days and 3 months via standard x-ray. - Patency at 30 days and 3 months via duplex scanning or angiography, whichever deemed most appropriate for follow up of each individual patient by the principal investigator. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT02044003
Study type Interventional
Source Philips Clinical & Medical Affairs Global
Contact
Status Completed
Phase N/A
Start date December 2009
Completion date December 2011

See also
  Status Clinical Trial Phase
Active, not recruiting NCT04534257 - Prospective Registry to Investigate the Safety and Efficacy of the Treatment With the Selution Sirolimus Drug Coated Balloon in TASC C and D Atheroma-occlusive Infra-Inguinal Disease in Patients With Chronic Limb Threatening Ischemia From Singapore N/A
Recruiting NCT04511234 - Sirolimus Coated Balloon Versus Standard Balloon for SFA and Popliteal Artery Disease N/A
Recruiting NCT03506633 - Impacts of Mitochondrial-targeted Antioxidant on Peripheral Artery Disease Patients N/A
Active, not recruiting NCT03506646 - Dietary Nitrate Supplementation and Thermoregulation N/A
Completed NCT02554266 - Registry Investigating the Clinical Use and Safety of the Lutonix Drug Coated Balloon for Treatment of BTK Arteries
Completed NCT03921905 - Peripheral Artery Disease in Patients With Stable Coronary Artery Disease in General Practice: Prevalence, Management and Clinical Outcomes.
Not yet recruiting NCT06369350 - Vitamin B6 on Exercise Pressor Reflex on Leg Ischemia-reperfusion Early Phase 1
Not yet recruiting NCT05063474 - Microvascular Reactivity in Peripheral Artery Disease
Recruiting NCT04545268 - Prehabilitation for Cardiac Surgery in Patients With Reduced Exercise Tolerance N/A
Recruiting NCT02389023 - Comparison of Prevena Negative Pressure Incision Management System vs. Standard Dressing After Vascular Surgery N/A
Completed NCT02563535 - Evaluation of the Use of ACOTEC Drug-Eluting Balloon Litos ® in Below-The-Knee Arteries to Treat Critical Limb Ischemia Phase 4
Completed NCT02539940 - Elutax-SV Drug-eluting Balloons for Below-the-knee Treatment
Completed NCT02522884 - Tack Optimized Balloon Angioplasty Study of the Tack Endovascular Systemâ„¢ in Femoropoliteal Arteries N/A
Completed NCT02542267 - In-Stent Restenosis Post-Approval Study N/A
Completed NCT02228564 - BARD® Study of LIFESTREAMâ„¢ Balloon Expandable Covered Stent Treating Iliac Arterial Occlusive Disease N/A
Completed NCT02145065 - First-in-man Evaluation of a Novel, Microcrystalline Paclitaxel Coated Balloon for Treatment of Femoropopliteal Artery Disease (PAX-r) N/A
Completed NCT02262949 - A Prospective Study of the Bard® LifeStent® Solo Vascular Stent System N/A
Completed NCT01743872 - Optical Imaging Measurement of Intravascular Solution Efficacy Trial N/A
Recruiting NCT01424020 - Walking Estimated Limitation Calculated by History - Study 2 Phase 4
Active, not recruiting NCT01597453 - NOR-SYS: The Norwegian Stroke in the Young Study N/A