Mimic Facial Muscles Clinical Trial
— SIMOVI-IRMOfficial title:
Quantification, Analysis and Simulation of Facial Mimics Movements
Verified date | February 2023 |
Source | Centre Hospitalier Universitaire, Amiens |
Contact | n/a |
Is FDA regulated | No |
Health authority | |
Study type | Interventional |
The SIMOVI project is a collaboration between our Department of Maxillofacial Surgery (CHU Amiens) and the Biomechanical bioengineer Research Department and Roberval Labs (Technological University of Compiègne). The question raised is the extent to which a facial mimic can be evaluated objectively. In today's clinical practice, the investigators use grading systems based on muscular scale or testing, in order to evaluate a facial muscular disorder. This assessment remains subjective because the investigators are deducing from surfacing cutaneous deformations the movement quality of the solicited muscle. This qualitative approach is therefore an approximate approach and deserves to be better thought to plan a surgical treatment which involves mimic facial muscle (as rehabilitation of facial palsy, cleft palate for example), to monitor the results, and to follow the recovery and progress in physiotherapy care. The aim of this study is to correlate external soft tissue movement (essentially cutaneous) during facial mimic with internal movement (essentially facial mimic muscle) using qualitative and QUANTITATIVE indicators, and to perform a biomechanical model of selected mimic face's movement using the precedent data.
Status | Completed |
Enrollment | 50 |
Est. completion date | February 2022 |
Est. primary completion date | February 2022 |
Accepts healthy volunteers | Accepts Healthy Volunteers |
Gender | All |
Age group | 20 Years to 30 Years |
Eligibility | Inclusion Criteria: - Caucasian subject - Ability to provide informed consent Exclusion Criteria: - Facial pathology - Facial trauma - Pregnant or breastfeeding. - Contraindications to MRI |
Country | Name | City | State |
---|---|---|---|
France | Amiens University Hospital | Amiens | Picardie |
Lead Sponsor | Collaborator |
---|---|
Centre Hospitalier Universitaire, Amiens | Regional Council Picardie, France |
France,
Autuori B, Bruyere-Garnier K, Morestin F, Brunet M, Verriest JP. Finite element modeling of the head skeleton with a new local quantitative assessment approach. IEEE Trans Biomed Eng. 2006 Jul;53(7):1225-32. doi: 10.1109/TBME.2006.872812. — View Citation
Barbarino GG, Jabareen M, Trzewik J, Nkengne A, Stamatas G, Mazza E. Development and validation of a three-dimensional finite element model of the face. J Biomech Eng. 2009 Apr;131(4):041006. doi: 10.1115/1.3049857. — View Citation
Bensamoun S, Stevens L, Fleury MJ, Bellon G, Goubel F, Ho Ba Tho MC. Macroscopic-microscopic characterization of the passive mechanical properties in rat soleus muscle. J Biomech. 2006;39(3):568-78. doi: 10.1016/j.jbiomech.2004.04.036. — View Citation
Bensamoun SF, Ringleb SI, Littrell L, Chen Q, Brennan M, Ehman RL, An KN. Determination of thigh muscle stiffness using magnetic resonance elastography. J Magn Reson Imaging. 2006 Feb;23(2):242-7. doi: 10.1002/jmri.20487. — View Citation
Brix M, Raphael B. [Labial function]. Ann Chir Plast Esthet. 2002 Oct;47(5):357-69. doi: 10.1016/s0294-1260(02)00129-2. French. — View Citation
Burres S, Fisch U. The comparison of facial grading systems. Arch Otolaryngol Head Neck Surg. 1986 Jul;112(7):755-8. doi: 10.1001/archotol.1986.03780070067015. — View Citation
Burres SA. Facial biomechanics: the standards of normal. Laryngoscope. 1985 Jun;95(6):708-14. doi: 10.1288/00005537-198506000-00013. — View Citation
Burres SA. Objective grading of facial paralysis. Ann Otol Rhinol Laryngol. 1986 May-Jun;95(3 Pt 1):238-41. doi: 10.1177/000348948609500306. — View Citation
Cacou C, Greenfield BE, Hunt NP, McGrouther DA. Patterns of coordinated lower facial muscle function and their importance in facial reanimation. Br J Plast Surg. 1996 Jul;49(5):274-80. doi: 10.1016/s0007-1226(96)90155-1. — View Citation
Chabanas M, Payan Y, Marecaux C, Swider P, Boutault F Comparison of linear and non linear soft tissue models with post-operative CT scan in maxillofacial surgery Lecture notes in computer science 2004, vol 3078, 19-27
Chevallier AM.Rééducation des paralysies faciales centrales et périphériques Encyclopédie Médico-Chirurgicale, Paris Kinésithérapie 26463 B10 5-1990, 16 p
Coulson SE, Croxson GR, Gilleard WL. Three-dimensional quantification of
Croxson G, May M, Mester SJ. Grading facial nerve function: House-Brackmann versus Burres-Fisch methods. Am J Otol. 1990 Jul;11(4):240-6. — View Citation
Deng J, Newton NM, Hall-Craggs MA, Shirley RA, Linney AD, Lees WR, Rodeck CH, McGrouther DA. Novel technique for three-dimensional visualisation and quantification of deformable, moving soft-tissue body parts. Lancet. 2000 Jul 8;356(9224):127-31. doi: 10.1016/S0140-6736(00)02449-1. — View Citation
Duchenne de Boulogne.La mécanique des passions. Paris ,1855
Ekman P, Friesen W.V .Unmasking the face: A guide to recognizing emotions from facial clues Consulting psychologists press (Palo Alto, Californie 1984)
Ermiane.R.Jeux musculaires et expressions du visage.Paris : Le François
Farrugia ME, Bydder GM, Francis JM, Robson MD. Magnetic resonance imaging of facial muscles. Clin Radiol. 2007 Nov;62(11):1078-86. doi: 10.1016/j.crad.2007.05.003. Epub 2007 Aug 9. — View Citation
Farrugia ME, Robson MD, Clover L, Anslow P, Newsom-Davis J, Kennett R, Hilton-Jones D, Matthews PM, Vincent A. MRI and clinical studies of facial and bulbar muscle involvement in MuSK antibody-associated myasthenia gravis. Brain. 2006 Jun;129(Pt 6):1481-92. doi: 10.1093/brain/awl095. Epub 2006 May 3. — View Citation
Gladilin E, Zackav S, Deufhard P, HEGE HC.Towards a realistic simulation of individual facial mimics Stuttgart, Germany, November 21-23, 2001
Hartl DM, Kolb F, Bretagne E, Bidault F, Sigal R. Cine-MRI swallowing evaluation after tongue reconstruction. Eur J Radiol. 2010 Jan;73(1):108-13. doi: 10.1016/j.ejrad.2008.10.005. Epub 2008 Dec 16. — View Citation
Ho Ba Tho MC Bone and joints modelling with individualised geometric and mechanical properties derived from medical images. Computer Mechanics and Engineering Sciences (2003) 4: 3&4. 489-496
Hontanilla B, Auba C. Automatic three-dimensional quantitative analysis for evaluation of facial movement. J Plast Reconstr Aesthet Surg. 2008;61(1):18-30. doi: 10.1016/j.bjps.2007.03.037. Epub 2007 Jun 13. — View Citation
House JW, Brackmann DE. Facial nerve grading system. Otolaryngol Head Neck Surg. 1985 Apr;93(2):146-7. doi: 10.1177/019459988509300202. No abstract available. — View Citation
Isono M, Murata K, Tanaka H, Kawamoto M, Azuma H. An objective evaluation method for facial mimic motion. Otolaryngol Head Neck Surg. 1996 Jan;114(1):27-31. doi: 10.1016/S0194-59989670279-6. — View Citation
Kleinheinz J, Joos U. Imaging of cartilage and mimic muscles with MRI: anatomic study in healthy volunteers and patients with unilateral cleft lip and palate. Cleft Palate Craniofac J. 2001 Jul;38(4):291-8. doi: 10.1597/1545-1569_2001_038_0291_iocamm_2.0.co_2. — View Citation
Lacide.M, Chevallier .AM Evaluation clinique de la fonction musculaire.
Le Double AF.Traité des variations du système musculaire de l'homme1897, Paris : Schleicher frères
Linstrom CJ, Silverman CA, Susman WM. Facial-motion analysis with a video and computer system: a preliminary report. Am J Otol. 2000 Jan;21(1):123-9. doi: 10.1016/s0196-0709(00)80086-1. — View Citation
Luboz V, Chabanas M, Swider P, Payan Y. Orbital and maxillofacial computer aided surgery: patient-specific finite element models to predict surgical outcomes. Comput Methods Biomech Biomed Engin. 2005 Aug;8(4):259-65. doi: 10.1080/10255840500289921. — View Citation
Meier-Gallati V, Scriba H, Fisch U. Objective scaling of facial nerve function based on area analysis (OSCAR). Otolaryngol Head Neck Surg. 1998 Apr;118(4):545-50. doi: 10.1177/019459989811800419. — View Citation
Paletz JL, Manktelow RT, Chaban R. The shape of a normal smile: implications for facial paralysis reconstruction. Plast Reconstr Surg. 1994 Apr;93(4):784-9; discussion 790-1. — View Citation
Payan Y, Chabanas M, Pelorson X, Vilain C, Levy P, Luboz V, Perrier P. Biomechanical models to simulate consequences of maxillofacial surgery. C R Biol. 2002 Apr;325(4):407-17. doi: 10.1016/s1631-0691(02)01443-9. English, French. — View Citation
Pessa JE, Zadoo VP, Adrian EK Jr, Yuan CH, Aydelotte J, Garza JR. Variability of the midfacial muscles: analysis of 50 hemifacial cadaver dissections. Plast Reconstr Surg. 1998 Nov;102(6):1888-93. doi: 10.1097/00006534-199811000-00013. — View Citation
Poirrier P, Charpy A.Traité d'anatomie humaine..Myologie, vol. 2, 1901, Paris, Masson
Rouvière H .Anatomie humaine descriptive, topographique et fonctionnelle.Tome 1, Tête et cou, 15e édition
Rubin LR. The anatomy of a smile: its importance in the treatment of facial paralysis. Plast Reconstr Surg. 1974 Apr;53(4):384-7. doi: 10.1097/00006534-197404000-00002. No abstract available. — View Citation
Sangeux M, Marin F, Charleux F, Durselen L, Ho Ba Tho MC. Quantification of the 3D relative movement of external marker sets vs. bones based on magnetic resonance imaging. Clin Biomech (Bristol, Avon). 2006 Nov;21(9):984-91. doi: 10.1016/j.clinbiomech.2006.05.006. Epub 2006 Jul 17. — View Citation
Sobotta.Atlas d'anatomie humaine - Tome 13 - Edition française.Edition Médicale Internationale, 1994
Testud L.Traité d'anatomie humaine.1899, Paris
Tomat LR, Manktelow RT. Evaluation of a new measurement tool for facial paralysis reconstruction. Plast Reconstr Surg. 2005 Mar;115(3):696-704. doi: 10.1097/01.prs.0000152431.55774.7e. — View Citation
Tran H V (2007) Determination of the mechanical properties of the skin in vivo. PhD Dissertation, Université de Technologie de Compiègne
Tran HV, Charleux F, Rachik M, Ehrlacher A, Ho Ba Tho MC. In vivo characterization of the mechanical properties of human skin derived from MRI and indentation techniques. Comput Methods Biomech Biomed Engin. 2007 Dec;10(6):401-7. doi: 10.1080/10255840701550287. Epub 2007 Sep 24. — View Citation
Wang S, Yang J, Gee JC. Advances in collision detection and non-linear finite mixed element modelling for improved soft tissue simulation in craniomaxillofacial surgical planning. Int J Med Robot. 2010 Mar;6(1):28-41. doi: 10.1002/rcs.286. — View Citation
Wang S, Yang J. Simulating cranio-maxillofacial surgery based on mixed-element biomechanical modelling. Comput Methods Biomech Biomed Engin. 2010 Jun;13(3):419-29. doi: 10.1080/10255840903317386. — View Citation
Wood DA, Hughes GB, Secic M, Good TL. Objective measurement of normal facial movement with video microscaling. Am J Otol. 1994 Jan;15(1):61-5. — View Citation
* Note: There are 46 references in all — Click here to view all references
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | Morphometric assessment of mimic facial muscle from 3T MRI data | The aim is to valid a method to identify, describe and measure the mimic facial muscles in 3 Tesla MRI. Through particular MRI acquisition developed especially for mimic facial muscle from routine acquisition, Morphometrics properties are calculated as length, volume, thickness and cross physiological section area. | 30 min | |
Secondary | Three dimensional quantitative analysis of mimics through motion capture | A VICON motion capture system with the Nexus 1.7.1 software will be used to capture expressive facial movements at a 120 Hz sample rate with 7 T160 cameras and 2 MX30 cameras. Markers of a diameter of 1.5 mm will be placed on the face. The localization of the markers is related to the muscles involved in the movements we want to study.
After data capture, we build and reconstruct our model. We chose a neutral pose as reference. The best parameters for the reconstruction will be determined. Kinematic parameters will be the markers displacement. |
01 hour | |
Secondary | Three dimensional quantitative mimic facial analysis with surface scan. | Three-dimensional image captured with a MH WHALE 3D Scanner. | 01 hour | |
Secondary | Three dimensional analysis with Digital Image Correlation | Recording three-dimensional images of the deformations of the face by two pairs of Pike CCD cameras from Allied Vision Technologies, with Schneider Xenoplan 2.0/28mm Lens, positioned on both sides of the face.
The calibration and the image processing will be made with the software suite VIC-SNAP, VIC-3D and 3D Fusion (Correlated Solutions) |
01 hour |