Clinical Trials Logo

Clinical Trial Summary

Total joint replacement is an efficacious treatment for osteoarthritis of hips and knees. Both total knee replacement (TKR) and total hip replacements (THR) have excellent implant survivorship. However, patient satisfaction is lower in TKR than THR. A possible cause of the discrepancy is the unnatural knee kinematics after TKR. Various implant designs have been developed to solve the problem. However, most of the designs are based on experimental data and not on in vivo kinematics. In this study, we will analyze the in vivo kinematics of the Global Medacta Knee Sphere (GMK Sphere) implant and compare it with a well documented design and implant (NexGen Cruciate Retaining (CR), Zimmer Biomet). We assume our study will contribute to the development of more satisfying knee implants.


Clinical Trial Description

Worldwide the number of patients requiring treatment for osteoarthritis is increasing due to increasing obesity, an ageing population and a high demanding younger population. Learmonth describes hip arthroplasty as the "operation of the century" because patients are highly satisfied with pain relief and function after the procedure. Knee arthroplasties have in recent years also shown promising results and have surpassed hip arthroplasty in frequency in western countries. However, patient satisfaction is not as high. Reported problems are insufficient function and persistent pain. On the other hand, knee arthroplasties are increasingly implanted in younger and more active patients who require high function and quality of life. Improvement of results after knee arthroplasty is therefore an urgent issue in the field of orthopaedic research. Knee kinematics and implant designs: A possible cause of lower function of replaced knees is the unnatural postoperative knee kinematics. The kinematics of replaced knees are closely related to their function. Studies show that replaced knees with excellent flexion angles have kinematic similarities to normal knees and malalignments of implants can cause postoperative pain. Compared to the hip joint which is a simple ball-and-socket joint, the kinematics of knee is more complex. Native knee kinematics are a combination of a rolling and gliding motion of the femoral condyles and rotation of the tibia, where roll back of the lateral femoral condyle is larger than medially. Roll back is important for high degrees of flexion. Native knee kinematics are not fully understood, but the anterior cruciate ligament (ACL) seems to be an integral part, as knees without a functioning ACL show decreased roll back. Based on the kinematics of the normal knee joint, various attempts have been made on the design of knee implants to reconstruct normal kinematics after replacement surgery, but in knee osteoarthritis the ACL and posterior cruciate ligament (PCL) is often deficient as they are damaged by inflammation. Therefore, there are three concepts regarding the retaining of these ligaments in knee replacement surgery. 1: Sacrifice both the ACL and PCL, 2: Retain the PCL (cruciate retaining (CR) design), 3: Retain both the ACL and PCL (bicruciate-reataining design). The function of the cruciate ligaments can be mimicked by different designs of the tibial insert. The CR design has been widely used in the northern countries, especially the Zimmer Biometri NexGen CR implant in Norway. There are migration data for the NexGen implant with high precision measurements available in the literature. However, the NexGen CR implant does not retain the ACL and does not mimic natural knee kinematics. The tibial insert of the medially stabilized implant design (Medacta International, GMK Sphere) has a constrained medial "ball in socket" joint and at the same time allows lateral anterioposterior movement (roll back). This new design was developed by a group of dedicated researchers. The design intention is to resemble the native kinematics of the knee by mimicing the function of the cruciate ligaments and at the same time allow for lateral anterioposterior movement (rollback). Theoretically, knee implant designs, which retain the function of cruciate ligaments are predicted to have the closest kinematics to normal knees compared to other designs and to have the potential to achieve the highest patient satisfaction. Analytical Method: Radiostereometric Analysis (RSA) has been used in orthopedic research fields since 1970s. The original application of this method was for the evaluation of implant migration (i.e. fixation) and polyethylene wear of artificial joints using static X-ray pictures. When combining RSA with fluoroscopy, we get Fluoroscopic Roentgen Stereophotogrammetric Analysis (FRSA), a method with high accuracy and precision. Few implants have been analysed kinematically in vivo. We plan to investigate the knees during in vivo motion and weight-bearing using FRSA. Purpose of the study: The aim of this study is to analyse the in vivo kinematics of a medially stabilized knee arthroplasty implant (GMK Sphere) and to compare it with a well known design (Nexgen CR, Zimmer Biomet) by using FRSA. By using flat panel fluoroscopy, we will document and compare the kinematics of the two implants in all 6 degrees of freedom (DOF). 26 patients will be randomized into two groups, one will receive the NexGen CR prosthesis, the other group the GMK Sphere. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT02965690
Study type Interventional
Source Oslo University Hospital
Contact
Status Active, not recruiting
Phase N/A
Start date November 2016
Completion date December 2025

See also
  Status Clinical Trial Phase
Recruiting NCT04651673 - Prescribed Knee Brace Treatments for Osteoarthritis of the Knee (Knee OA)
Completed NCT05677399 - Knee Osteoarthritis Treatment With Peloidotherapy and Aquatic Exercise. N/A
Active, not recruiting NCT04043819 - Evaluation of Safety and Exploratory Efficacy of an Autologous Adipose-derived Cell Therapy Product for Treatment of Single Knee Osteoarthritis Phase 1
Recruiting NCT06000410 - A Study to Evaluate the Efficacy of Amniotic Suspension Allograft in Patients With Osteoarthritis of the Knee Phase 3
Completed NCT05014542 - Needling Techniques for Knee Osteoarthritis N/A
Recruiting NCT05892133 - Prehabilitation Effect on Function and Patient Satisfaction Following Total Knee Arthroplasty N/A
Recruiting NCT05528965 - Parallel Versus Perpendicular Technique for Genicular Radiofrequency N/A
Active, not recruiting NCT03472300 - Prevalence of Self-disclosed Knee Trouble and Use of Treatments Among Elderly Individuals
Active, not recruiting NCT02003976 - A Randomized Trial Comparing High Tibial Osteotomy Plus Non-Surgical Treatment and Non-Surgical Treatment Alone N/A
Active, not recruiting NCT04017533 - Stability of Uncemented Medially Stabilized TKA N/A
Completed NCT04779164 - The Relation Between Abdominal Obesity, Type 2 Diabetes Mellitus and Knee Osteoarthritis N/A
Recruiting NCT04006314 - Platelet Rich Plasma and Neural Prolotherapy Injections in Treating Knee Osteoarthritis N/A
Recruiting NCT05423587 - Genicular Artery Embolisation for Knee Osteoarthritis II N/A
Enrolling by invitation NCT04145401 - Post Market Clinical Follow-Up Study- EVOLUTION® Revision CCK
Active, not recruiting NCT03781843 - Effects of Genicular Nerve Block in Knee Osteoarthritis N/A
Recruiting NCT05974501 - Pre vs Post Block in Total Knee Arthroplasty (TKA) Phase 4
Completed NCT05324163 - Evaluate Efficacy and Safety of X0002 in Treatment of Knee Osteoarthritis Phase 3
Completed NCT05529914 - Effects of Myofascial Release and Neuromuscular Training for Pes Anserine Syndrome Associated With Knee Osteoarthritis N/A
Recruiting NCT05693493 - Can Proprioceptive Knee Brace Improve Functional Outcome Following TKA? N/A
Not yet recruiting NCT05510648 - Evaluation of the Effect of High-intensity Laser Therapy in Knee Osteoarthritis N/A