Heart Failure (HF) is a cardiovascular disease secondary to a structural and / or functional alteration of the heart that prevents its correct function. The Cardiac resynchronization therapy (CRT) aims to restore atrioventricular, inter and intraventricular synchrony in patients with systolic HF and wide depolarization of the ventricles (QRS). Although CRT has been shown to be effective, the rate of non-responders is high (30-50%). One of the proposed reasons for the lack of response to the CRT is the lack of intrinsic conduction, since most of the time CRT is administered using biventricular stimulation (BiV). One of the limitations to achieve ventricular fusion are the dynamic physiological variations of the auriculo-ventricular (AV) interval. The SyncAVTM algorithm is a new dynamic algorithm that manages to adjust the AV intervals outside the clinic. The design of the present clinical study is post-marketing, prospective, multicenter, randomized and blind for the patient and the central echocardiography laboratory. The objective of this study is to assess whether CRT with ventricular stimulation with fusion using the SyncAVTM algorithm is superior to CRT with conventional BiV stimulation in the population for which its use is foreseen. The data will be collected in at least the Selection / Baseline Visit and in the Visit of Follow-up at 6 Months. The study population are subjects to whom an Abbott Medical CRT has been implanted with SyncAVTM® Stimulation function that go to the participating sites in the study. The main objective of the study is to assess whether CRT with ventricular stimulation with fusion using the SyncAVTM algorithm is superior to CRT with BiV stimulation conventional in terms of the rate of responders. The main endpoint is the determination of significant differences between conventional BiV stimulation and ventricular stimulation with fusion using the SyncAVTM algorithm in terms of the percentage of patients responding to CRT therapy with echocardiogram. The duration of the clinical study is estimated at 24 months with a recruitment period of 18 months and a patient follow-up of 6 months. The number of subjects that is planned to be recruited is 176. The inclusion will be competitive and there is no inclusion number determined per site.


Clinical Trial Description

Study design The study is designed post-marketing, prospective, multicenter, randomized and blind for the patient and for the Core-laboratory of the echocardiogram (ECO) department. Has this design is post- marketing since it is a sanitary product with European Committee (CE) marking that is already commercialized and will be used in the study according to its instructions for use. Is a blind study since neither the participant subject nor the Core-laboratory of the ECO (person in charge to assess the main variable of the study) know the treatment that has been randomized the subject, it is a randomized study because the group assignment of each subject is done randomly 1:1. Study evaluation Evaluation of the risk and benefits of the study: The following will be taking into account 1. Expected clinical benefits: - Stimulation function with the SyncAV algorithm is expected increase the rate of responders to therapy. - These two methods improve function VI (ventricle left) and it is believed that this additional improvement of the VI function could benefit patients who do not respond to BiV conventional stimulation. 2. Expected adverse effects of the product: bleeding/acute hemorrhage, gas aeration, acceleration of arrythmias, cysts formation, erosion,exacerbation of cardiac insufficiency, venous or cardiac perforation, excessive fibrous tissue development, bruising, histotoxic reactions, infection, keloid formation, myocardial irritability, infection, hematoma, excessive bleeding, local tissue reaction, loss of stimulation and/or detection due to migration or mechanical malfunction, myocardial irritability, stimulation of the nerve, etc. All those events are inherent to the implant of the device for cardiac resynchronization therapy 3. Risk associated with participation in this clinical trial: It is expected that the risks associated with the use of the SyncAVTM stimulation algorithm be comparable to the risks associated with other types of ventricular pacing, and therefore, the risks associated with the use of the stimulation algorithm are expected SyncAVTM will not differ from the risks associated with the different modes of Conventional stimulation available. Patients will be included in the study after the successful implantation of a CRT device, whose indication will be made clinically based on the guidelines current clinical practice of the European Society of Cardiology (ESC). 4. Possible interactions with concomitant medical treatments and / or Simultaneous medical interventions: No interaction with concomitant pharmacological treatments and / or medical interventions simultaneous, apart from those that occur in the usual treatment with any CRT device. All participants will be candidates for the implantation of a CRT device and will be included in the clinical study once the device has been implanted successfully. Main Valuation criterion: The main endpoint of the study is to determine if there are differences significant differences between conventional BiV stimulation and ventricular pacing with fusion using the SyncAVTM algorithm in terms of the percentage of patients responders to CRT therapy The positive response to CRT is defined as an improvement> 15% in the Systolic Volume End in the Left Ventricle (VSFVI) 6 months after implantation, evaluated by echocardiography. ▪ Secondary rating criterion The secondary endpoints of this study are differences between: - Inverse remodeling of the VI, measured as the changes in the interval (VTSVI), Volume Telediastolic Left Ventricle (VTDVI), Telesystolic Diameter Left Ventricle (DTSVI), Telediastolic Diaphragm of the Left Ventricle (DTDVI) and Left Ventricular Ejection Fraction (LVEF) at 6 months, in comparison with the Basal situation without stimulation. - Comparison of the aforementioned echocardiographic parameters with the cohort of patients stratified according to the etiology (ischemic patients versus to non-ischemic patients): or The percentage of super-responder patients * at 6 months. or dyssynchrony measured by the rate of deformation (echocardiography with the speckle tracking technique ) between the anteroseptal segment and the posterior wall (if available). or Electrode position VI: o Short axis (posterolateral, lateral, anterolateral). o Long axis (apical, midventricular, Basal). - New York Heart Association (NYHA) Class Change at 6 months. - Mortality from any cause after 6 months. - Hospitalization rate for any cause, due to cardiovascular causes and / or heart failure, at 6 months. - Combined mortality and hospitalization variable for heart failure a 6 months - Quality of life variable according to Kansas City Cardiomyopathy Questionnaire (KCCQ)-12 survey - % auricular fibrilation (FA) (no patients / FA load) SAFETY ASSESSMENT The safety of the stimulation algorithms will be evaluated by collecting and registering of any dysfunction, alteration of the features or performance of the product that could or could have led to the death or serious deterioration of the state of health of a patient or a user. Therefore, safety has as an evaluation criterion the Record and analyze the frequency and intensity of adverse incidents that occur throughout the study. For the evaluation of safety, the Population of Security (PS). Evaluation of effectiveness The superior efficacy of CRT with ventricular stimulation with fusion through SyncAVTM algorithm versus CRT with conventional BiV stimulation will be studied comparing the results of the stimulation logarithms between the two branches of the study (stimulation by SyncAVTM algorithm and conventional BiV stimulation).The ultimate goal of the study is to determine the percentage of responding patients and not respondents The response of patients to CRT will be evaluated taking into account the reduction of VSFVI. Patients will be classified as responders. have documented a reduction in VSFVI of at least 15% compared to the data collected in the Basal situation without stimulation. The evaluation of the effectiveness will be analyzed with the Population of Intent to Treat (ITT) and Population by Protocol (PP). Sample size The calculation of the sample size is based on the main variable: the proportion of responders to CRT at 6 months with the SyncAV function activated at the start of the study. The main variable of the study is the response to re-synchronization, understood as a dichotomous variable that takes the values: Yes / No. In the study there will be two randomization groups, and the response rate of the control group is set at 65% of the patients, while that of the study group will be 77%, that is, 12% higher. As statistical criteria for the estimation of the sample size, it was used a confidence level of 95%, a margin of non-inferiority δ = 0 and a power a priori of 80%. The statistical technique used for the analysis of the main variable is a test χ 2 The formula used to calculate the sample size is as follows (Chow, Shao and Wang, 2008): In addition, it is assumed that 5% of patients may be lost due to loss of follow-up and 8% due to exitus. For the calculation of the sample size, the R-studio software (version 1.0.153). Applying the formula, the sample size is 77 patients per group, that is, a total of 154 patients. However, 22 more must be added (11 more patients in each group) due to possible loss of follow-up and due to death. Considering all the above information, the expected sample size is of 176 patients, 88 patients would be randomized to the control group and 88 to the group of study. Using an exact binomial test of a unilateral sample, with a level of significance of 95%, a total of 176 patients would be necessary to reach a 80% power. To detect a difference of 12% between the two responder rates, it is It is necessary that a total of 176 patients have analysable data at 6 months. Based on clinical experience, it is assumed that some patients will abandon the study (5% during the first 6 months of implantation, 8% due to exitus) STATISTICAL ANALYSIS Statistical design, hypothesis, method and analytical procedures: The analysis of the main variable will be based on the intention to treat principle (ITT), including all deviations from the Protocol. There will also be a secondary analysis per Protocol (PP), excluding all deviations of the Protocol. If the results obtained in these analyzes were different, an exploration of the data will be done in search of the reasons. In the analysis of the main variable will be evaluated the following hypothesis of inequality: - H0: Proportion of responders at 6 months with ventricular stimulation with fusion using SyncAVTM algorithm <Proportion ofResponders at 6 months with conventional BiV stimulation. - H1: Proportion of responders at 6 months with ventricular stimulation with fusion using the SyncAVTM algorithm > Proportion ofResponders at 6 months with conventional BiV stimulation. All results will be expressed according to the corresponding intervals confidence of 97.5% and the values p. P values less than 2.5% are will consider significant. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT03961399
Study type Interventional
Source Hospital Universitari Vall d'Hebron Research Institute
Contact
Status Completed
Phase N/A
Start date December 18, 2018
Completion date October 27, 2021

See also
  Status Clinical Trial Phase
Recruiting NCT05196659 - Collaborative Quality Improvement (C-QIP) Study N/A
Recruiting NCT05654272 - Development of CIRC Technologies
Recruiting NCT05650307 - CV Imaging of Metabolic Interventions
Active, not recruiting NCT05896904 - Clinical Comparison of Patients With Transthyretin Cardiac Amyloidosis and Patients With Heart Failure With Reduced Ejection Fraction N/A
Completed NCT05077293 - Building Electronic Tools To Enhance and Reinforce Cardiovascular Recommendations - Heart Failure
Recruiting NCT05631275 - The Role of Bioimpedance Analysis in Patients With Chronic Heart Failure and Systolic Ventricular Dysfunction
Enrolling by invitation NCT05564572 - Randomized Implementation of Routine Patient-Reported Health Status Assessment Among Heart Failure Patients in Stanford Cardiology N/A
Enrolling by invitation NCT05009706 - Self-care in Older Frail Persons With Heart Failure Intervention N/A
Recruiting NCT04177199 - What is the Workload Burden Associated With Using the Triage HF+ Care Pathway?
Terminated NCT03615469 - Building Strength Through Rehabilitation for Heart Failure Patients (BISTRO-STUDY) N/A
Recruiting NCT05679713 - Next-generation, Integrative, and Personalized Risk Assessment to Prevent Recurrent Heart Failure Events: the ORACLE Study
Completed NCT04254328 - The Effectiveness of Nintendo Wii Fit and Inspiratory Muscle Training in Older Patients With Heart Failure N/A
Completed NCT03549169 - Decision Making for the Management the Symptoms in Adults of Heart Failure N/A
Recruiting NCT05572814 - Transform: Teaching, Technology, and Teams N/A
Enrolling by invitation NCT05538611 - Effect Evaluation of Chain Quality Control Management on Patients With Heart Failure
Recruiting NCT04262830 - Cancer Therapy Effects on the Heart
Active, not recruiting NCT06026683 - Conduction System Stimulation to Avoid Left Ventricle Dysfunction N/A
Withdrawn NCT03091998 - Subcu Administration of CD-NP in Heart Failure Patients With Left Ventricular Assist Device Support Phase 1
Recruiting NCT05564689 - Absolute Coronary Flow in Patients With Heart Failure With Reduced Ejection Fraction and Left Bundle Branch Block With Cardiac Resynchronization Therapy
Completed NCT04549181 - Problem-Solving for Rural Heart Failure Dyads N/A