Diurnal fluctuations of intraocular pressure in EX-Press Valve Blebs in Glaucoma Patients

Intraocular pressure (IOP) reduction is the mainstay of glaucoma management. (1) Open-angle glaucoma (OAG) is generally managed by decreasing the intraocular pressure (IOP) to a level that the physician believes will prevent further glaucomatous damage. However, in a significant proportion of patients, the visual fields continue to deteriorate in spite of office pressures within the range of normal values (8). It has been suggested that the progressive damage in some cases could be caused by peaks of IOP or diurnal IOP variability not detected by tonometry during office hours. It is possible that certain drugs or surgical interventions are more effective than others in dampening these fluctuations. The purpose of our study is to compare the diurnal IOP fluctuations in glaucoma patients treated with medications or Ex-press filtration surgery.


Clinical Trial Description

Diurnal fluctuations of intraocular pressure in EX-Press Valve Blebs in Glaucoma Patients

Department of Ophthalmology, Hillel-Yaffe Medical Center, affiliated with the Bruce Rappaport School of Medicine, The Technion, Haifa, Israel

Introduction:

Intraocular pressure (IOP) reduction is the mainstay of glaucoma management. (1) Medication alone is sometimes not sufficient to reduce excessively high IOP, and pharmaceutical intolerance may develop or damage can occur to the optic nerve, warranting surgical intervention. (2) The filtering bleb is considered to be the cornerstone of IOP control after glaucoma filtration surgery drainage device implantation. (3) It enables the flow of the aqueous humor from the anterior chamber to the subconjunctiva, episclera, sclera and choroid, thereby lowering the IOP. (4-6) Filtration and drainage devices, such as the EX-Press device (Alcon Laboratories, Fort Worth, Texas, USA), offer a surgical alternative to glaucoma medical therapy. (7) Open-angle glaucoma (OAG) is generally managed by decreasing the intraocular pressure (IOP) to a level that the physician believes will prevent further glaucomatous damage. However, in a significant proportion of patients, the visual fields continue to deteriorate in spite of office pressures within the range of normal values (8). It has been suggested that the progressive damage in some cases could be caused by peaks of IOP or diurnal IOP variability not detected by tonometry during office hours. (9, 10) In another study, Asrani et al. (11) showed that IOP fluctuations are an independent risk factor in patients with glaucoma and as such may need to be treated specifically. It is possible that certain drugs or surgical interventions are more effective than others in dampening these fluctuations. The purpose of our study is to compare the diurnal IOP fluctuations in glaucoma patients treated with medications or Ex-press filtration surgery.

Materials and Methods The study will include 20 open-angle glaucoma (OAG) patients underwent Ex-Press filtration surgery, and 20 OAG patients treated with medications alone. All patients will have 12 IOP measurements with 2 hours interval, starting at 10 AM until 10 AM of the following morning.

ICARE® PRO tonometer (Icare Finland Oy, Espoo, Finland) will be used for the measurement of IOP. The rebound motion of its light weighted probe will be recorded during contact of the probe with the cornea. (12, 13) The rate of deceleration of the probe is a function of IOP. The ICARE® PRO has a built-in inclination sensor that allows downward measurement of the eye in the supine position as well as in the normal upright sitting position. ICARE® PRO allows for measurement of IOP in the seated and supine positions. During IOP recording, patients will be supine or upright, and the tip of the probe will be applied perpendicular to the cornea. Two markers engraved on the piston of the probe indicated its ideal positioning. The reliability of the measurement is displayed on the ICARE® PRO tonometer screen and guided our measurements.

Fluctuations in IOP will be compared between the Ex-press filtration surgery eye and the fellow (intra-group comparison). Inter-group comparison of IOP fluctuation will be performed between the Ex-press filtration surgery eye and medically treated eye of different patients. ;


Study Design

Observational Model: Cohort, Time Perspective: Prospective


Related Conditions & MeSH terms


NCT number NCT02665884
Study type Observational
Source Hillel Yaffe Medical Center
Contact Yuval Cohen, MD., PhD
Phone 0586904951
Email dr.yuvalcohen@gmail.com
Status Not yet recruiting
Phase N/A
Start date February 2016
Completion date February 2017

See also
  Status Clinical Trial Phase
Recruiting NCT06000865 - Glaucoma Rehabilitation With Action viDeo Games and Exercise - GRADE N/A
Recruiting NCT06278597 - Automatic Evaluation of the Anterior Chamber Angle Width by a New Non-contact Optical Device N/A
Active, not recruiting NCT04271709 - Manhattan Vision Screening and Follow-Up Study (NYC-SIGHT) N/A
Recruiting NCT03274024 - The Asia Primary Tube Versus Trab (TVT) Study N/A
Completed NCT04552964 - Assessment of the Impact of an add-on and Its Smartphone Application on the Daily Management of Glaucoma N/A
Recruiting NCT01957267 - Functional and Structural Imaging for Glaucoma
Active, not recruiting NCT04624698 - iStent Inject New Enrollment Post-Approval Study N/A
Completed NCT04020705 - The Efficacy of Citicoline in Eyedrops (OMK1) in Reducing the Progression of Glaucoma N/A
Completed NCT03150160 - Additive Effect of Twice-daily Brinzolamide 1%/Brimonidine 0.2%Combination as an Adjunctive Therapy to Travoprost in Patients With Normal Tension Glaucoma Phase 4
Not yet recruiting NCT05581498 - Glaucoma Exercise as Medicine Study (GEMS). N/A
Recruiting NCT02921568 - Side-by-Side Comparison of P200TE and Spectral OCT/SLO on Diseased Eyes N/A
Active, not recruiting NCT02901730 - Clinical Study of LPI With Different Laser Wavelengths N/A
Completed NCT02955849 - A Trial of China Laser and Surgery Study Glaucoma in Rural China Early Phase 1
Recruiting NCT02554214 - Pilot Clinical Trial on a New Adjustable Glaucoma Drainage Device N/A
Recruiting NCT02471105 - Investigation of IOP and Tolerability of Bimatoprost 0.01% and Tafluprost Unit Dose Preservative Free 15 Microgram/ml Phase 4
Active, not recruiting NCT02390284 - Stop Retinal Ganglion Cell Dysfunction Study Phase 3
Completed NCT02246764 - Study of Netarsudil (AR-13324) Ophthalmic Solution in Patients With Glaucoma or Ocular Hypertension Phase 3
Completed NCT02628223 - 180 Degree vs. 360 Degree Selective Laser Trabeculoplasty as Initial Therapy for Glaucoma N/A
Completed NCT02520674 - Glaucoma Screening With Smartphone Ophthalmology N/A
Completed NCT02390245 - Philadelphia Telemedicine Glaucoma Detection and Follow-Up Study N/A