Clinical Trials Logo

Clinical Trial Summary

A randomized clinical trial (RCT) was designed. The participants were randomly allocated into either of the two groups intervention or control group each of 14 participants. Participants in control group (Group-A) received conventional manufactured implant overdenture while participants in intervention group (Group-B) received CAD-CAM manufactured implant overdenture.


Clinical Trial Description

Introduction: Mandibular single implant overdenture is a well-established treatment modality that address limited financial resources of patients and simultaneously enabled the management of conventional complete denture problems. CAD/CAM technology helped to mitigate the problems encountered with conventional fabrication techniques, which results in improved dentures fit and retention. Therefore, the aim of the current trial study was to evaluate whether overdentures fabricated using CAD/CAM printed technology exhibited improved patient satisfaction, denture retention, implant survival rate and decreased post-insertion maintenance or not compared to overdentures manufactured using conventional techniques. Methods: A randomized clinical trial (RCT) was designed. The participants were randomly allocated into either of the two groups intervention or control group each of seven participants. Participants in control group (Group-A) received conventional manufactured implant overdenture while participants in intervention group (Group-B) received CAD-CAM manufactured implant overdenture. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04366895
Study type Interventional
Source October University for Modern Sciences and Arts
Contact
Status Completed
Phase N/A
Start date January 20, 2021
Completion date August 21, 2022

See also
  Status Clinical Trial Phase
Active, not recruiting NCT04984499 - In Vivo Clinical Investigation of the Safety and Performance of Dental Implants TBR® Tissue Level Z1
Completed NCT01411683 - Mandibular Overdentures Retained by Conventional or Mini Implants N/A
Completed NCT04853459 - A Technique for Border Molding in Complete Dentures Using Light-Cured N/A
Not yet recruiting NCT06458738 - Clinical Evaluation of a New Printable Denture Base Material N/A
Completed NCT01230320 - Simplified vs. Conventional Methods for Complete Denture Fabrication N/A
Completed NCT05614635 - Safety and Technical Performance of Plastalgin and Plastalgin Fast in Patients Requiring a Dental Impression
Active, not recruiting NCT05599269 - Retrospective Clinical Evaluation of Nano-hybrid-composite Denture Teeth N/A
Not yet recruiting NCT03674554 - Prosthetic Complications of Screw Retained Restoration N/A
Not yet recruiting NCT06155630 - 3D Printing for the Fabrication of Mandibular Implant Overdentures N/A
Active, not recruiting NCT02117856 - Complete Lower Dentures on 1 or 2 Implants N/A
Not yet recruiting NCT06393582 - Accuracy Evaluation of Implant Impressions: A Prospective Study N/A
Recruiting NCT05375045 - Real-life Evaluation of the Safety and Performance of EUROTEKNIKA Dental Implants
Recruiting NCT06255522 - Clinical and Anatomical Factors Influencing Accuracy in Fully Guided Implant Placement. N/A
Completed NCT04760457 - Mandibular Overdentures Retained by Mini Implants: a Clinical Trial Comparing Different Surgical and Loading Protocols N/A
Completed NCT03126942 - Single-implant Overdentures Retained by the Novaloc Attachment System N/A
Enrolling by invitation NCT05441527 - Use of Two Dissolvable Therapeutics Under Removable Partial Dentures N/A
Completed NCT03056976 - Cost-effectiveness of Implant Treatment for the Edentulous Mandible N/A
Completed NCT04475913 - Digital vs Analog Impression in Cases of All-on-4 - Prosthesis N/A
Recruiting NCT03536468 - Psychological Impact of Tooth Loss
Completed NCT03048812 - Attachment Types for Single-implant Mandibular Overdentures: a Crossover Clinical Trial N/A