Clinical Trials Logo

Clinical Trial Summary

To confirm the safety and performance of the DynamX Sirolimus-eluting Coronary Bioadaptor System (SECBS) in de novo native coronary artery lesions using clinical and imaging endpoints. Clinical follow-up will be conducted in all patients at 30 days, 6 and 12 months. Imaging follow-up will be conducted at 6 months.


Clinical Trial Description

The DynamX Sirolimus Study is a prospective, consecutive enrollment, single-arm study designed to enroll up to 30 patients requiring treatment of up to two de novo lesions ≤ 24 mm in length in vessels ≥ 2.5 mm and ≤ 3.5 mm in diameter. One or two designated target lesions, located in separate epicardial vessels (RCA, LCX or LAD), and meeting the inclusion/exclusion criteria may be treated with the DynamX SECBS. Alternatively, one target lesion may be treated with the DynamX SECBS after successful, uncomplicated treatment of a non-target lesion, located in a separate epicardial vessel, with any commercially-available DES. Acceptable example: non-target RCA lesion and LAD target lesion. Not acceptable example: LAD non-target lesion and 1st diagonal target lesion. The primary safety endpoint is Target Lesion Failure at 6 months. TLF is a composite endpoint defined as cardiac death, target vessel MI, and clinically-indicated target lesion revascularization The primary efficacy endpoint is late lumen loss at 6 months, assessed by angiography Additional secondary safety and effectiveness endpoints will be evaluated at 30 days, 6 and 12 months Using visual assessment, the target lesion must measure ≥ 2.5 mm and ≤ 3.5 mm in diameter and ≤ 24 mm in length able to be covered by a single DynamX Sirolimus Bioadaptor including 2 mm of healthy vessel on either side of the planned treatment area. The patient will be eligible for stent (also called bioadaptor) implantation only after satisfactory lesion pre-dilatation defined as: ≥ TIMI 2 flow, and no dissection greater than Grade B (NHLBI) able to be covered with a single DynamX SECBS ;


Study Design


Related Conditions & MeSH terms


NCT number NCT03634020
Study type Interventional
Source Elixir Medical Corporation
Contact
Status Completed
Phase N/A
Start date December 10, 2018
Completion date March 8, 2021

See also
  Status Clinical Trial Phase
Recruiting NCT06030596 - SPECT Myocardial Blood Flow Quantification for Diagnosis of Ischemic Heart Disease Determined by Fraction Flow Reserve
Completed NCT04080700 - Korean Prospective Registry for Evaluating the Safety and Efficacy of Distal Radial Approach (KODRA)
Recruiting NCT03810599 - Patient-reported Outcomes in the Bergen Early Cardiac Rehabilitation Study N/A
Recruiting NCT06002932 - Comparison of PROVISIONal 1-stent Strategy With DEB Versus Planned 2-stent Strategy in Coronary Bifurcation Lesions. N/A
Not yet recruiting NCT06032572 - Evaluation of the Safety and Effectiveness of the VRS100 System in PCI (ESSENCE) N/A
Recruiting NCT05308719 - Nasal Oxygen Therapy After Cardiac Surgery N/A
Recruiting NCT04242134 - Drug-coating Balloon Angioplasties for True Coronary Bifurcation Lesions N/A
Completed NCT04556994 - Phase 1 Cardiac Rehabilitation With and Without Lower Limb Paddling Effects in Post CABG Patients. N/A
Recruiting NCT05846893 - Drug-Coated Balloon vs. Drug-Eluting Stent for Clinical Outcomes in Patients With Large Coronary Artery Disease N/A
Recruiting NCT06027788 - CTSN Embolic Protection Trial N/A
Recruiting NCT05023629 - STunning After Balloon Occlusion N/A
Completed NCT04941560 - Assessing the Association Between Multi-dimension Facial Characteristics and Coronary Artery Diseases
Completed NCT04006288 - Switching From DAPT to Dual Pathway Inhibition With Low-dose Rivaroxaban in Adjunct to Aspirin in Patients With Coronary Artery Disease Phase 4
Completed NCT01860274 - Meshed Vein Graft Patency Trial - VEST N/A
Recruiting NCT06174090 - The Effect of Video Education on Pain, Anxiety and Knowledge Levels of Coronary Bypass Graft Surgery Patients N/A
Completed NCT03968809 - Role of Cardioflux in Predicting Coronary Artery Disease (CAD) Outcomes
Terminated NCT03959072 - Cardiac Cath Lab Staff Radiation Exposure
Recruiting NCT05065073 - Iso-Osmolar vs. Low-Osmolar Contrast Agents for Optical Coherence Tomography Phase 4
Recruiting NCT04566497 - Assessment of Adverse Outcome in Asymptomatic Patients With Prior Coronary Revascularization Who Have a Systematic Stress Testing Strategy Or a Non-testing Strategy During Long-term Follow-up. N/A
Completed NCT05096442 - Compare the Safety and Efficacy of Genoss® DCB and SeQuent® Please NEO in Coronary De Novo Lesions N/A