Coronary Artery Disease Clinical Trial
Official title:
Evaluation of a Thin Strut Metallic Coronary Device: the Elixir DynamXTM Sirolimus Eluting Coronary Bioadaptor System
To confirm the safety and performance of the DynamX Sirolimus-eluting Coronary Bioadaptor System (SECBS) in de novo native coronary artery lesions using clinical and imaging endpoints. Clinical follow-up will be conducted in all patients at 30 days, 6 and 12 months. Imaging follow-up will be conducted at 6 months.
The DynamX Sirolimus Study is a prospective, consecutive enrollment, single-arm study designed to enroll up to 30 patients requiring treatment of up to two de novo lesions ≤ 24 mm in length in vessels ≥ 2.5 mm and ≤ 3.5 mm in diameter. One or two designated target lesions, located in separate epicardial vessels (RCA, LCX or LAD), and meeting the inclusion/exclusion criteria may be treated with the DynamX SECBS. Alternatively, one target lesion may be treated with the DynamX SECBS after successful, uncomplicated treatment of a non-target lesion, located in a separate epicardial vessel, with any commercially-available DES. Acceptable example: non-target RCA lesion and LAD target lesion. Not acceptable example: LAD non-target lesion and 1st diagonal target lesion. The primary safety endpoint is Target Lesion Failure at 6 months. TLF is a composite endpoint defined as cardiac death, target vessel MI, and clinically-indicated target lesion revascularization The primary efficacy endpoint is late lumen loss at 6 months, assessed by angiography Additional secondary safety and effectiveness endpoints will be evaluated at 30 days, 6 and 12 months Using visual assessment, the target lesion must measure ≥ 2.5 mm and ≤ 3.5 mm in diameter and ≤ 24 mm in length able to be covered by a single DynamX Sirolimus Bioadaptor including 2 mm of healthy vessel on either side of the planned treatment area. The patient will be eligible for stent (also called bioadaptor) implantation only after satisfactory lesion pre-dilatation defined as: ≥ TIMI 2 flow, and no dissection greater than Grade B (NHLBI) able to be covered with a single DynamX SECBS ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT06030596 -
SPECT Myocardial Blood Flow Quantification for Diagnosis of Ischemic Heart Disease Determined by Fraction Flow Reserve
|
||
Completed |
NCT04080700 -
Korean Prospective Registry for Evaluating the Safety and Efficacy of Distal Radial Approach (KODRA)
|
||
Recruiting |
NCT03810599 -
Patient-reported Outcomes in the Bergen Early Cardiac Rehabilitation Study
|
N/A | |
Recruiting |
NCT06002932 -
Comparison of PROVISIONal 1-stent Strategy With DEB Versus Planned 2-stent Strategy in Coronary Bifurcation Lesions.
|
N/A | |
Not yet recruiting |
NCT06032572 -
Evaluation of the Safety and Effectiveness of the VRS100 System in PCI (ESSENCE)
|
N/A | |
Recruiting |
NCT05308719 -
Nasal Oxygen Therapy After Cardiac Surgery
|
N/A | |
Recruiting |
NCT04242134 -
Drug-coating Balloon Angioplasties for True Coronary Bifurcation Lesions
|
N/A | |
Completed |
NCT04556994 -
Phase 1 Cardiac Rehabilitation With and Without Lower Limb Paddling Effects in Post CABG Patients.
|
N/A | |
Recruiting |
NCT05846893 -
Drug-Coated Balloon vs. Drug-Eluting Stent for Clinical Outcomes in Patients With Large Coronary Artery Disease
|
N/A | |
Recruiting |
NCT06027788 -
CTSN Embolic Protection Trial
|
N/A | |
Recruiting |
NCT05023629 -
STunning After Balloon Occlusion
|
N/A | |
Completed |
NCT04941560 -
Assessing the Association Between Multi-dimension Facial Characteristics and Coronary Artery Diseases
|
||
Completed |
NCT04006288 -
Switching From DAPT to Dual Pathway Inhibition With Low-dose Rivaroxaban in Adjunct to Aspirin in Patients With Coronary Artery Disease
|
Phase 4 | |
Completed |
NCT01860274 -
Meshed Vein Graft Patency Trial - VEST
|
N/A | |
Recruiting |
NCT06174090 -
The Effect of Video Education on Pain, Anxiety and Knowledge Levels of Coronary Bypass Graft Surgery Patients
|
N/A | |
Completed |
NCT03968809 -
Role of Cardioflux in Predicting Coronary Artery Disease (CAD) Outcomes
|
||
Terminated |
NCT03959072 -
Cardiac Cath Lab Staff Radiation Exposure
|
||
Recruiting |
NCT05065073 -
Iso-Osmolar vs. Low-Osmolar Contrast Agents for Optical Coherence Tomography
|
Phase 4 | |
Recruiting |
NCT04566497 -
Assessment of Adverse Outcome in Asymptomatic Patients With Prior Coronary Revascularization Who Have a Systematic Stress Testing Strategy Or a Non-testing Strategy During Long-term Follow-up.
|
N/A | |
Completed |
NCT05096442 -
Compare the Safety and Efficacy of Genoss® DCB and SeQuent® Please NEO in Coronary De Novo Lesions
|
N/A |