Clinical Trials Logo

Clinical Trial Details — Status: Recruiting

Administrative data

NCT number NCT01543022
Other study ID # 184916
Secondary ID
Status Recruiting
Phase Phase 1/Phase 2
First received February 27, 2012
Last updated May 1, 2013
Start date November 2011
Est. completion date June 2014

Study information

Verified date May 2013
Source Abiomed Inc.
Contact Carol Loring
Phone 781-646-1595
Email cloring@abiomed.com
Is FDA regulated No
Health authority Canada: Health Canada
Study type Interventional

Clinical Trial Summary

The Counter Pulsation Device (CPD) System 'Symphony' is intended to provide counter pulsation therapy for up to thirty (30) days to patients with chronic heart failure who have persistent worsening of their condition despite optimal medical therapy. Patients will be in New York Heart Association (NYHA) Class IIIb or IV heart failure and have exhausted all medical or surgical options.


Recruitment information / eligibility

Status Recruiting
Enrollment 10
Est. completion date June 2014
Est. primary completion date December 2013
Accepts healthy volunteers No
Gender Both
Age group 19 Years and older
Eligibility Inclusion Criteria:

1. New York Heart Association Class IIIB or IV heart failure despite optimal medical therapy, including ACE inhibitors, beta blockers, IV diuretics and pressors

2. Left Ventricular Ejection Fraction < 40%.

3. Patient is not a candidate for conventional catheter-based or surgical intervention such as valve intervention or coronary artery bypass surgery.

4. Patient is not currently a candidate for heart transplantation or placement of a left ventricular assist device (LVAD) as bridge to heart transplantation due to co-morbidities. Patients may become a candidate for these options if they have improvement on the device due to improved cardiac output.

5. Patients have exhausted all approved surgical and medical therapies as determined by a heart failure cardiologist and a surgeon with expertise in heart failure.

6. Patient has been evaluated by a multi-disciplinary research team and felt to be a suitable candidate for a research study. The final decision regarding the patient's candidacy for research will remain with the attending cardiologist and heart surgeon.

7. Improved hemodynamics on device support will allow for potential for physical rehabilitation.

8. Signed Informed Consent, or oral informed consent with written confirmation by uninvolved third party

9. Age of subject at least 19 years

Exclusion Criteria:

1. High likelihood of death during the current hospitalization (as judged by the attending physician) and condition other than heart failure that would limit survival to less than two years.

2. Require mechanical ventilation.

3. Failure to wean from IABP, Impella, ECMO or other mode of circulatory support.

4. Complex arrhythmias that negatively impact the effectiveness of counter pulsation.

5. Dependency on high dose inotropes.

6. Cerebrovascular accident or TIA within the previous 3 months.

7. Contraindication to anticoagulation medication such as Heparin, Coumadin, Aspirin and Plavix.

8. Presence of hypercoaguable state or history of idiopathic venous or arterial thrombosis.

9. Severe calcification in the target vessel that will preclude insertion of the Symphony device.

10. Moderate to severe aortic insufficiency (2+ or more).

11. Ongoing systemic infection defined as two of the following:

- WBC > 12,500

- positive blood culture

- fever

12. Abnormal pre-albumin (< 13mg/dL), or albumin (< 3.0 mg/dl)

13. A cardiac rhythm that cannot be used to trigger the CPD (sinus rhythm, ventricular or atrial pacing, A-V pacing).

14. Abnormal bilateral carotid Doppler or CT exam define as > 50% stenosis.

15. Subclavian artery internal diameter of < 7 mm on Doppler study or CT exam.

16. Ability to ambulate < 200 metres on a 6 minute walk test.

17. Any aortic aneurysmal disease.

18. Active documented HIT.

19. Presence of mechanical heart valve.

20. Moderate to severe RV failure.

21. Severe tricuspid regurgitation.

22. History of major psychiatric illness.

23. End-organ dysfunction including:

- renal failure defined as serum Cr > 2.5 mg/dl,

- liver dysfunction defined as bilirubin 2X normal, or elevated INR with no anticoagulation,

- respiratory failure defined as FEV1 < 50% predicted.

24. Chest X-ray to rule out pulmonary pathology that increases the risk of need for treatment prior to device implant.

25. BMI > 40 kg/ m2.

26. Active participation in another clinical trial that may interfere with this trial.

Study Design

Endpoint Classification: Safety/Efficacy Study, Intervention Model: Single Group Assignment, Masking: Open Label, Primary Purpose: Treatment


Related Conditions & MeSH terms


Intervention

Device:
Symphony
The Symphony system has been developed for superficial implantation without the need to enter the chest. It allows for complete patient mobility and provides counter pulsation therapy for up to 30 days in hospitalized patients.
Procedure:
The operative approach is limited to an infraclavicular incision similar to that used for placement of a pacemaker
The vascular graft is surgically attached (anastomosed) to the subclavian artery. The symphony device is implanted into a pocket below the pectoralis muscle on the anterior chest and attached to the graft. The driveline is tunneled out through the skin and attached to the drive console.

Locations

Country Name City State
Canada London Health Sciences Center, University Hospital London Ontario
Canada Royal Victoria Hospital Montreal Quebec
Canada St. Paul's Hospital Vancouver British Columbia

Sponsors (1)

Lead Sponsor Collaborator
Abiomed Inc.

Country where clinical trial is conducted

Canada, 

Outcome

Type Measure Description Time frame Safety issue
Primary Death, Stroke or Transient Ischemic Attack (TIA), Limb Ischemia requiring surgical intervention The trial will primarily look at patient safety defined as proportion of composite Major Adverse Events (MAE) up to hospital discharge or 30 days of CPD support, whichever is longer. hospital discharge or 30 days of support, whichever is longer Yes
See also
  Status Clinical Trial Phase
Completed NCT03597646 - The Effect of Kinesio Taping on Pulmonary Function and Functional Capacity in Patients With Chronic Heart Failure N/A
Terminated NCT04065997 - Apogee International
Withdrawn NCT03675113 - Effect of Upper Extremity Aerobic Exercise Training on Exercise Capacity Patients With Chronic Heart Failure N/A
Completed NCT02916160 - Sacubitril-valsartan and Heart Failure Patients : the ENTRESTO-SAS Study Phase 4
Completed NCT03126656 - Effects of Testosterone on Myocardial Repolarization Phase 4
Completed NCT02247245 - The Influence of Heart Rate Limitation on Exercise Tolerance in Pacemaker Patients. N/A
Completed NCT02268500 - VAccination to Improve Clinical outComes in Heart Failure Trial: a Feasibility Study (VACC-HeFT) Phase 4
Completed NCT01919918 - Muscle Afferent Feedback Effects in Patients With Heart Failure Phase 1
Terminated NCT01906957 - Cognition and Exercise Training N/A
Not yet recruiting NCT01669395 - Severe Heart Failure and Homebased Rehabilitation - An Intersectoral Randomized Controlled Trial N/A
Completed NCT00984529 - Evaluation of Clinical Signs and Symptoms of Chronic Heart Failure in Patients Treated With Candesartan Cilexetil in Croatia N/A
Recruiting NCT00863421 - Sleep Disordered Breathing in Patients With Chronic Heart Failure N/A
Completed NCT02840565 - Tolerability, Pharmacokinetics and Pharmacodynamics of Six Multiple Rising Dose Regimens of BIA 5-453 Phase 1
Completed NCT02441218 - Effects of Ivabradine on Cardiovascular Events in Patients With Moderate to Severe Chronic Heart Failure and Left Ventricular Systolic Dysfunction. A Three-year International Multicentre Study Phase 3
Completed NCT00149409 - Omega-3-Polyunsaturated Fatty-Acids (N3-Pufa) In Patients With Severe Chronic Heart Failure Phase 2/Phase 3
Terminated NCT05532046 - A Study to Learn How Safe Study Drug BAY2413555 is, How it Affects the Body, and How it Moves Into, Through, and Out of the Body Over 4 Weeks of Use in Participants With Heart Failure and Implanted Cardiac Defibrillator or Cardiac Resynchronization Devices (ICD/CRT) Phase 1
Recruiting NCT04984928 - Readmission Risk of Patients With Heart Failure.
Completed NCT02814097 - A Study to Evaluate the Effects of 4 Weeks Treatment With Subcutaneous Elamipretide on Left Ventricular Function in Subjects With Stable Heart Failure With Preserved Ejection Fraction Phase 2
Active, not recruiting NCT05560737 - ODYSSEE-vCHAT Mental Health Program for Heart Failure and Kidney Disease Patients
Recruiting NCT03286127 - Palliative Outcome Evaluation Muenster I