Cervix Cancer Clinical Trial
Official title:
Validation Study of Modeled Intra-pelvic Organ Motion During External Beam Radiotherapy for Cervix Cancer Using Frequent Magnetic Resonance Imaging
Patients with cervix cancer having radiotherapy experience side-effects because the radiotherapy fields have to be quite large to account for tumour movement in the pelvis during treatment, this irradiates a lot of normal tissues. This study aims to characterize and model the tumour motion, as well as the motion of surrounding normal tissues, during treatment. By doing this, the investigators can look at ways to minimise tumour motion and spare more normal tissues. By tailoring the radiotherapy dose more accurately, the investigators will reduce the side-effects of treatment and improve local control of the tumour. By doing multiple magnetic resonance imaging (MRI) scans of the patients during treatment, the investigators can identify where the tumour and surrounding normal tissues are at that point in time. Collecting all the information from these scans, will allow the investigators to model the motion of the tumour and these pelvic organs, and investigate the best way to target the tumour while still sparing normal tissues.
At simulation: patients will have two MRI scans in addition to the standard planning CT scan. One MRI scan will be with bladder full, the other will be with bladder empty. During treatment: patients will have two or three MRI scans per week at their convenience. MRI scans will be scheduled close to radiotherapy treatment times to minimise inconvenience for the patient. On the same day they have an MRI scan, they will also have a CBCT at the time of treatment. None of the images will be used to alter or influence the treatment the patient is receiving. If the patient feels that the imaging schedule is too inconvenient, they will be given the option to reduce the frequency of the scanning or to withdraw from the study.All the images will be loaded onto a password secure server. The MRI scans will be fused to the planning CT scan using bone-to-bone matching. Tumour and intra-pelvic organs will be contoured on the MRI scans. The contours will be used to create surface meshes of each organ and with research software, we will be able to model the motion and deformation of these organs over the course of radiotherapy. Using this data, we will be able to simulate the dose impact of the organ motion on different intensity-modulated radiotherapy plans. We will also explore the impact of bladder & rectal filling on tumour motion. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT04067882 -
Validation of the Genetic Signature 354849 as a Prognostic Method
|
||
Completed |
NCT00329589 -
A Trial Using Velcade Plus Chemoradiation for Central Nervous System, Head and Neck, and Cervical Cancer Patients
|
Phase 1 | |
Recruiting |
NCT05743517 -
Physical Activity Intervention Among Older Women With Gynecologic Cancers (Fit4Treatment)
|
N/A | |
Completed |
NCT05234112 -
Prevention and Screening Towards Elimination of Cervical Cancer
|
N/A | |
Completed |
NCT04258553 -
Thiol Disulfide Balance in Cervix Cancer
|
||
Completed |
NCT03956498 -
Impact of a Sexological Follow-up on the Sexual Function in Patients With Cervix or Vaginal Cancer Treated by Radiotherapy and Brachytherapy
|
N/A | |
Active, not recruiting |
NCT04357873 -
Efficacy of Immunotherapy Plus a Drug in Patients With Progressive Advanced Mucosal Cancer of Different Locations
|
Phase 2 | |
Completed |
NCT00509444 -
Cancer Prevention and Treatment Among African American Older Adults: Treatment Trial
|
Phase 3 | |
Completed |
NCT00379743 -
Partnership for Healthy Seniors
|
N/A | |
Recruiting |
NCT06022029 -
A Dose Escalation and Dose Expansion Study of Intratumoral ONM-501 Alone and in Combination With Cemiplimab in Patients With Advanced Solid Tumors and Lymphomas.
|
Phase 1 | |
Recruiting |
NCT06116019 -
Online Adaptive Radiotherapy Using a Novel Linear Accelerator (ETHOS)
|
||
Completed |
NCT04072913 -
Matrix Metalloproteinases and Human Papillomavirus in Dysplasias and Cancers of the Cervix
|
N/A | |
Active, not recruiting |
NCT06452004 -
Validation of Artificial Intelligence as Decision Support System in VIA (PRESCRIP-TEC)
|
N/A | |
Recruiting |
NCT04651127 -
Anti-PD-1 Antibody Combined With Histone Deacetylase Inhibitor in Patients With Advanced Cervical Cancer
|
Phase 1/Phase 2 | |
Recruiting |
NCT06010875 -
A Clinical Research About CD70-targeted CAR-T in the Treatment of CD70-positive Advanced/Metastatic Solid Tumors
|
Phase 1 | |
Completed |
NCT02552121 -
Tisotumab Vedotin (HuMax®-TF-ADC) Safety Study in Patients With Solid Tumors
|
Phase 1/Phase 2 | |
Completed |
NCT02001623 -
Tisotumab Vedotin (HuMax®-TF-ADC) Safety Study in Patients With Solid Tumors
|
Phase 1/Phase 2 | |
Completed |
NCT02997553 -
Fluorescence for Sentinel Lymph Node Identification in Cancer Surgery
|
Phase 3 | |
Terminated |
NCT02233387 -
PET CT With HX4 in Cervix Cancer
|
Phase 2 | |
Completed |
NCT01766284 -
Study of the Diagnostic Efficacy of "Real Time" Niris 1300e Optical Coherence Tomography (OCT) Imaging System in the Management of Pre-invasive and Invasive Neoplasia of the Uterine Cervix
|
N/A |