Clinical Trial Summary

The goal of this clinical trial is to evaluate two separate operating room cataract measuring tools in predicting the residual astigmatism (prediction error) in patients with corneal astigmatism. The main question it aims to answer is: Show the refractive predictability comparing the use of Operating Room cataract toric lens placement tools against the standard manual technique. Participants will be implanted with the TECNIS Toric II IOL Lens Model ZCU; the second eye, if applicable, is to be implanted within 45 days of the first-eye surgery. Researchers will compare two Operating Room cataract lens placement tools: the Zeiss CALLISTO vs. the Wavetec AnalyzOR to determine refractive predictability.


Clinical Trial Description

To evaluate two separate operating room cataract measuring tools in predicting the residual astigmatism (prediction error) in patients with corneal astigmatism (maximum allowable up to 3.0D) comparing the ZEISS CALLISTO eye and the Wavetec AnalyzOR at the one-month post-operative visit. Both surgery rooms will be using Veracity, IOL Master and Zeiss Opmi Lumera i Operating Room Microscopes. Operating Room #1 will be utilizing the ZEISS CALLISTO eye for axis alignment, along with Veracity and IOL Master for lens selection, and Operating Room #2 will be utilizing the Wavetec AnalyzOR for lens selection and axis alignment. Procedure times for the ZEISS CALLISTO eye and the Wavetec AnalyzOR will be obtained by using a start/stop watch, including phakic power calculation and toric positioning. In addition, the suction on (start of LenSx), treatment time of LenSx in seconds, suction off (end of LenSx), start time of primary incision, the beginning of Phaco, end of phaco, CDE (Combined Diffused Energy) total and the end time of procedure will all be documented. All times will be analyzed and compared between Operating Room #1 and Operating Room #2. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT06216067
Study type Observational
Source Chesapeake Eyecare and Laser Center, LLC
Contact
Status Completed
Phase
Start date December 14, 2021
Completion date July 21, 2023

See also
  Status Clinical Trial Phase
Completed NCT04685538 - Chloroprocaine 3% Gel Eye Drop as Topical Anestheticsin Phacoemulsification. Phase 3
Recruiting NCT06060041 - IC-8 Apthera IOL New Enrollment Post Approval Study
Recruiting NCT05518539 - Evaluation of Quality of Vision and Visual Outcomes With Bilateral Implantation of the Clareon PanOptix Intraocular Lens
Recruiting NCT05271942 - Tilt and Tumble vs Divide and Conquer - a Unique Comparison of the Two Cataract Surgery Methods N/A
Active, not recruiting NCT04778501 - PMCF Study on Monofocal Toric IOL (PODEYE TORIC) in Asia N/A
Completed NCT05062564 - Efficacy of LipiFlow in Patients Affected by Meibomian Gland Dysfunction in Reducing Post-cataract Surgery Dry Eye N/A
Completed NCT03751033 - Influence of DisCoVisc Ophthalmic Viscosurgical Device (OVD) on Intraoperative Aberrometry Readings N/A
Completed NCT02529488 - Investigation of AcrySof® IQ PanOptix™ Presbyopia-Correcting Intraocular Lens (IOL) Model TFNT00 N/A
Completed NCT04539548 - A Study Assessing the Safety and Efficacy of Dextenza® for the Treatment of Ocular Pain and Inflammation Following Surgery for Pediatric Cataract Phase 3
Completed NCT03740659 - Evaluation Of Aqueous Humor Of Levofloxacin-Dexamethasone Eye Drops And Of Its Components In Patients Undergoing Cataract Surgery Phase 2
Completed NCT03494257 - Effect of Fixed Brinzolamide-brimonidine Combination on Intraocular Pressure After Phacoemulsification N/A
Completed NCT05119127 - Rotational Stability of Acrysof IQ Vivity Extended Vision Toric IOL and Refractive Visual Outcome. N/A
Active, not recruiting NCT04271709 - Manhattan Vision Screening and Follow-Up Study (NYC-SIGHT) N/A
Recruiting NCT03713268 - Intraoperative OCT Guidance of Intraocular Surgery II
Completed NCT03739528 - Levo-Dexa vs. Tobra+Dexa for Prevention and Treatment of Inflammation and Prevention of Infection in Cataract Surgery Phase 3
Completed NCT02888210 - A Study Assessing Safety and Efficacy of MD-15 Intraocular Lens in Patients With Aphakic Eye After Cataract Surgery Phase 3
Completed NCT03356847 - Evaluation of the Rotational Stability of the Monofocal SISA Implant Following Cataract Surgery N/A
Completed NCT04332640 - Clinical Evaluation of the Next Generation Phaco System N/A
Recruiting NCT03638726 - Subconjunctival Atropine and Intracameral Epinephrine for Pupil Dilation in Phacoemulsification Phase 4
Completed NCT03050697 - Evaluation of the Safety and Performance of the HARMONI® Toric Lens N/A