Clinical Trials Logo

Clinical Trial Summary

1. To determine whether a risk-based screening programme for occult paroxysmal atrial fibrillation, involving extended cardiac monitoring in adults with CHA2DS2-VASc score of 3 or greater, increases the detection of new atrial fibrillation/flutter. 2. To determine whether a risk-based screening programme for occult paroxysmal atrial fibrillation, involving extended cardiac monitoring in adults with CHA2DS2-VASc score of 3 or greater, is cost-effective. 3. To determine the sensitivity, specificity, positive predictive value and negative predictive values of self-monitoring of pulse in adults for detection of atrial fibrillation. 4. To determine the cost, cost effectiveness, and budget impact of a risk-based screening programme for occult paroxysmal atrial fibrillation, relative to a control of usual care in general practice.


Clinical Trial Description

Stroke is a leading cause of death and disability. A first diagnosis of atrial fibrillation may occur at the time of stroke (e.g. about 45% of patients with acute stroke). Undiagnosed atrial fibrillation is therefore a major care-gap in stroke prevention. Against this backdrop, oral anticoagulant therapy is extremely effective at reducing the risk of ischemic stroke in atrial fibrillation, associated with a two-thirds risk reduction. Therefore, a major care gap in stroke prevention is the prevalence of undetected atrial fibrillation in the community. Traditional pulse screening in all patients > 65 years detects new atrial fibrillation in about 1% of people. The CHA2DS2-VASc score was developed and validated to risk-stratify patients with atrial fibrillation into low, intermediate and high risk of stroke. The Investigators believe that the CHA2DS2-VASc score represents an opportunity to identify patients at high risk of atrial fibrillation, but also identifies this at highest risk of stroke, and therefore those that will derive greatest benefit from anticoagulant therapy. The advent of external-worn event loop recorders (ELRs) present a more convenient and efficient method of detecting atrial fibrillation. Loop recorders have an in-built diagnostic algorithm that identifies atrial fibrillation, and initiates recordings before and after the event-trigger. This rhythm strip is then examined and confirmed by the trial cardiac technician. The investigators will examine if using external loop recorders in patients identified as high risk will improve the detection rate of paroxysmal atrial fibrillation. The study is a randomised controlled cross-over multi-centered clinical trial in General Practice. Ethical approval has been sought from the Galway University Hospitals research ethics committee. The investigators have also engaged with Clinical Research Patient and Public Involvement. The investigators primary research question is whether extended cardiac rhythm monitoring (with ELR for 1 week), compared to standard care, in patients pre-identified to be at high-risk of atrial fibrillation (defined by CHA2DS2-VASc score >2) increases the detection of new atrial fibrillation resulting in introduction of oral anticoagulant therapy, that is efficient, acceptable to patients and cost-effective. All participating general practices will require the Socrates software package. The investigators will run analyses to identify patients with a CHA2DS2-VASc of 3 or greater. The investigators will exclude all patients with known atrial fibrillation, those in whom contraindications to oral anticoagulant therapy exist, and those who are deemed unsuitable for extended monitoring. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT03911986
Study type Interventional
Source National University of Ireland, Galway, Ireland
Contact
Status Completed
Phase N/A
Start date March 21, 2018
Completion date December 31, 2023

See also
  Status Clinical Trial Phase
Enrolling by invitation NCT06056557 - Versatility of a Circular Multielectrode Catheter in the Individualized Recognition & Treatment of Atrial Fibrillation and Related Arrhythmias Using Pulsed Field Energy N/A
Recruiting NCT03862859 - The Danish Warfarin-Dialysis Study - Safety and Efficacy of Warfarin in Patients With Atrial Fibrillation on Dialysis Phase 4
Completed NCT03788044 - Effect of Targeted Education for Atrial Fibrillation Patients (Application Substudy) N/A
Completed NCT03707873 - Effect of Targeted Education for Atrial Fibrillation Patients N/A
Active, not recruiting NCT05009225 - Clinical Decision Support for Atrial Fibrillation and Flutter
Recruiting NCT02623049 - Direct Oral Anticoagulants Pharmacodynamics in Octogenarian Patients With Atrial Fibrillation
Completed NCT05509517 - A Clinical Trial of the Use of Remote Heart Rhythm Monitoring With a Smartphone After Cardiac Surgery N/A
Completed NCT03377465 - Biomarkers, Hemodynamic and Echocardiographic Predictors of Ischemic Strokes and Their Influence on the Course and Prognosis N/A
Completed NCT03243604 - cARdiotoxicity Profile of aBIraTeRone in prostAte Cancer : a pharmacoviGilancE Study
Recruiting NCT04855890 - HIgh Power Short Duration Radiofrequency Ablation or Cryoballoon Ablation for Paroxysmal Atrial Fibrillation N/A
Active, not recruiting NCT03110627 - Increasing Detection of Sub-Clinical Atrial Fibrillation in Defibrillator Patients With the Use of a VDD-ICD Lead N/A
Completed NCT03472495 - Oral vs Intravenous Diltiazem for Rapid Atrial Fibrillation/Flutter Trial Phase 4
Recruiting NCT04438395 - Dielectric Tissue Imaging in Cavotricuspid Isthmus Ablation
Completed NCT02344901 - ReAl-life Multicentre Survey Evaluating Stroke Prevention Strategies (RAMSES) N/A
Completed NCT02273609 - INR Control and Atrial Fibrillation in Primary Care in Spain (PAULA) N/A
Recruiting NCT05159180 - Development of a New Impedance Mapping System for Ablation of Atrial Arrhythmias in Patients
Recruiting NCT06187155 - Impact of Education Level on Clinical Outcomes in Self-INR Managed Patients N/A
Active, not recruiting NCT03488420 - Canadian EdoxAban(Lixiana®) Registry in Patients With ATrial Fibrillation/Flutter With Confirmed ValvUlar HeaRt DiseasE
Completed NCT05008601 - Aino ECG Ambulatory Study