Clinical Trials Logo

Clinical Trial Summary

Coronary artery blockages can reduce blood flow to the heart muscle. Fractional flow reserve (iFR or FFR) assessment is an invasive tool used to determine how much blood flow is reduced. The investigators will perform iFR/FFR on all intermediate coronary stenoses using standard practice, immediately before (at the time of) transcatheter aortic valve replacement (TAVR) and after successful TAVR. The investigators will compare pre- and post-TAVR iFR/FFR values, and assess short-term outcomes. The investigators hypothesize that iFR/FFR values will be consistently and significantly higher pre-TAVR in comparison with post-TAVR for the same lesions.


Clinical Trial Description

The purpose of the study is to determine whether iFR assessment gives a valid assessment of coronary hemodynamics in patients with severe aortic stenosis. Several factors confound the interpretation of fractional flow reserve (FFR) in patients with severe aortic stenosis (AS) and intermediate severity coronary stenoses, and the widely accepted cut-off value of 0.80 may not be applicable to this patient population. Coronary flow reserve is known to be attenuated under conditions of left ventricular hypertrophy and severe AS, with one study showing improvement in coronary flow reserve after aortic valve replacement. Left ventricular hypertrophy produces fixed resistance secondary to external compression of the coronary microcirculation. This potentially results in failure to achieve maximal hyperemia with adenosine and can lead to false negative FFR results. Neurohormonal influences in aortic stenosis can further attenuate vasodilator response and potentially result in false negative FFR values. Both of these conditions result in the potential deferral of lesions which may have been hemodynamically significant in the absence of severe AS. At present, there are no studies which have demonstrated validity of FFR measurement in patients with severe AS. Here, the investigators propose a prospective study of iFR/FFR in patients with AS and indeterminate coronary lesions undergoing TAVR to understand the hemodynamic consequences of AS on iFR/FFR. The investigators hypothesize that iFR/FFR values will be consistently and significantly higher pre-TAVR in comparison with post-TAVR for the same lesions. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT03442400
Study type Interventional
Source The Cleveland Clinic
Contact
Status Terminated
Phase N/A
Start date February 14, 2018
Completion date August 10, 2021

See also
  Status Clinical Trial Phase
Recruiting NCT04310046 - Optimal Timing of Transcatheter Aortic Valve Implantation and Percutaneous Coronary Intervention - The TAVI PCI Trial N/A
Recruiting NCT06008080 - Post-Market Clinical Follow Up Study With Navitor Valve
Recruiting NCT06055751 - Long Term Evaluation of Cardiac Arrhythmias After Transcatheter Aortic Valve Implantation -The LOCATE Registry
Active, not recruiting NCT04815785 - Safety and Efficacy of TaurusOne® Transcatheter Aortic Valve System in Patients With Severe Calcific Aortic Stenosis N/A
Terminated NCT02202434 - Safety and Efficacy Study of Lotus Valve for Transcatheter Aortic Valve Replacement N/A
Recruiting NCT03029026 - The Role of Occult Cardiac Amyloid in the Elderly With Aortic Stenosis.
Active, not recruiting NCT02903420 - A Clinical Trial of Transcatheter Aortic Valves in Dialysis Patients (Japan) N/A
Completed NCT02629328 - CardioCel Tri-leaflet Repair Study N/A
Completed NCT02306226 - Symetis ACURATE Neo™ Valve Implantation SAVI TF Registry
Withdrawn NCT01648309 - Neuropsychological Testing in Patients Undergoing Transvascular Aortic Valve Implantation N/A
Completed NCT01676727 - ADVANCE Direct Aortic Study
Completed NCT01422044 - Risk Prediction in Aortic Stenosis N/A
Withdrawn NCT00774657 - Ventricular Remodeling In Patients With Aortic Stenosis Assessed Echocardiography N/A
Terminated NCT00535899 - Speckle Tracking Imaging in Patients With Low Ejection Fraction Aortic Stenosis (SPArKLE-AS) N/A
Terminated NCT05070130 - OpSens PRIME CLASS
Completed NCT03314857 - China XT: Safety and Effectiveness of Edwards Lifesciences SAPIEN XT THV in the Chinese Population N/A
Completed NCT04157920 - Impact of Predilatation Between Self-expanding Valves N/A
Enrolling by invitation NCT06212050 - Feasibility, Safety, and Effectiveness of the ACURATE neo2 Transcatheter Heart Valve for Severe Bicuspid Aortic Stenosis
Recruiting NCT05893082 - Multicenter Feasibility Trial of the F2 Filter and Delivery System for Embolic Protection During TAVR N/A
Completed NCT03250806 - Early Detection of Aortic Stenosis in the Community During Flu Vaccination